Loading...
Eckerd's-LR 990125 (4) G · GEOTECHNICAL ENGINEI;KING E · ENVIRONMENTAL CONSULTING GEE Consultants, Inc. E · CONSTRUCTION MATERIALS TESTING 10046 Monroe Drive · Dallas, Texas 75229 · (214) 352-5433 · Fax (214) 352-6972 REPORT OF' IN-PLACE DENSITY AND MOISTURE OF SOIl. Density Report No. 14 (298-0412) Method: ASTM D2922 D3017 D698 Page 1 of Client: North American Properties Material Descriotion Maximum Optimum Dry, Moisture Density Content Project: Eckerds (LbslCuFt~ Percent Coppell, Texas 1. Dark Brown Clay 96.4 21.0 2. Orange & Gray Clayey Sand (Select Fill) 105.3 12.6 Test Date: January 20, 1999 z. Dark Brown Clay 100.2 19.2 4. Brown Clay(Lime Treated) 98.7 20.0 Report Date: January 25, 1999 s. Dark Brown Clay(Lime Treated) 96.1 19.4 Required Density (%): 95% - 105% Required Moisture (%): Opt +5% (Clay) Opt +_3% (Sand) Mat Location/Elevation I, and/or) Lift ln-Plae~ In-Place Percent No. Dry, Density Moisture Compaction Test No. (LbsiCuFt) Content Probe Dc'pm 5 Retest # 40 43 91.5 21.3 95.2 6" 5 Retest # 42 44 92.4 20.4 96.2 6" Tests meet project specifications cc: Mr. John Maggiore - North American Properties Mr. Lance Lilly - Richmond Group Mr. Gar}, Stokes - C. A. Walker Construction Mr. Lee Stone - City of Coppell Mr. Lar~ Davis-City of Coppell ~.~/~