Eckerd's-LR 990104 (2) GEOTECHNICAL ENGINE,...,NG GEE Consultants, Inc. CONSTRUCTION MATERIALS TESTING 10046 Monroe Drive · Dallas, Texas 75229 · (214) 352-5433 · Fax (214) 352-6972 REPORT OF IN-PLACE DENSITY AND MOIS OF SOIl. Density Report No. 12 (298-0412) Method: ASTM D2922 D3017 D698 Page 1 of 1 Client: North American Properties Material Descriouon Maximum Optimum Dry Moisture Density Content Project: Eckerds (LbsiCuFt) Percent Coppell, Texas 96.4 21.0 1. Dark Brown Clay Test Date: December 31, 1998(3:00 pm) z. Orange & Gray Clayey Sand (Select Fill) 105.3 12.6 3. Dark Brown Clay 100.2 19.2 Report Date: January 4, 1999 Required Density (%): 95% - 105% Required Moisture (%): Opt +5% (Clay) Opt _+3% (Sand) Mat Locauon/Elevation (and/or) Lift [n-Place In-Place Percent No. D~' Densay Mo,sture Compacuon Test No. (LbsiCuF0 Content Probe Depth 1 Retest # 38 - 1st Lift 39 ~' 80' N. of detector check vault - 30" above fire line 96.5 21.8 100.1 6" Test meets project specifications cc: Mr. John Maggiore - North American Properties Mr. Lance Lilly - Richmond Group Mr. GaD' Stokes - C. A. Walker Construction Mr. Lee Stone - Citx' of Coppel! aaron' t'n~~L.~ Mr. LarD' Davis - ~ity of Coppell Our letters and repons are for the exclusive use of the client to whom they. are addressed. The use of our receive our p r written approval. Our letters and reports apply only to the sample tested and/or inspected, and are not necessarily indicative of the quantities of apparently identical or similar products.