Denton Tap L2R BA-LR010302FUGRO SOUTH, INC. - 2880 Virgo Lane; Dallas. Texas 75229 Ph (972) 484-8301' Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Preston Engineering Report Date: March 2, 2001 PROJECT: Everybody Fits, Coppell. Texas Project No.: 0701-2035 SAMPLE DATE: February 22, 2001 CONTRACTOR: Preston Engineering TICKET NO.: 94111 CONCRETE SUPPLIER: Nelson Brothers AMBIENT TEMP. (~F): 57 PLANT/TRUCK: 210 CONCRETE TEMP. (=F) (ASTM C-1064): 64 MIX ID NUMBER: 5 SACK TIME BATCHED: 9:00 AIR TIME SAMPLED: 10:45 WATER ADDED (gal): 0 WEATHER CONDITION: Sunny/windy SLUMP (in.) (ASTM C-143): 5 LOCATION OF PLACEMENT: Slab, 2"-" floor northwest corner by stairs CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches I TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) EFC 9 7 02/28/01 70700 2500 3000/28 days EFC 10 28 03/22/01 EFC 11 28 03/22/01 EFC 12 Hold Fracture mode is (A) unless other,vise noted Specifications: rv'laking & ASTM C-3! 'resting ASTM C-143. T'.,'pessf ~ ['~ [~-/] Curing: Methods: ASTM C-39 Fracture: A B C D REMARKS: Technician: Jeff Jedlicka FUGRO SOUTH INC. Reviewed By:__..._ SMHirm Distribution: Preston Engineering - Timothy D. McMahon. P.E. FUGRO SOUTH, INC. - 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Preston Engineering Report Date: March 2, 2001 PROJECT: Everybody Fits, Coppell, Texas Project No.: 0701-2035 SAMPLE DATE: February 22, 2001 CONTRACTOR: Preston Engineering TICKET NO.: 94110 CONCRETE SUPPLIER: Nelson Brothers AMBIENT TEMP. (=F): 57 PLANT/TRUCK: 209 CONCRETE TEMP. (:F) (ASTM C-1064): 65 MIX ID NUMBER: 5 SACK TIME BATCHED: 8:55 AIR (%) (ASTM C-231): TIME SAMPLED: 10:30 WATER ADDED (gal): 5 WEATHER CONDITION: Sunny/windy SLUMP (in.) (ASTM C-143): 5 LOCATION OF PLACEMENT: Pier: E.5-4 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) EFC 5 7 02/29/01 85200 3010 3000/28 days EFC 6 28 03/22/01 EFC 7 28 03/22/01 EFC 8 Hold i Fracture mode is (A) unless otherwise noted Specifications: i M. akipg& ASTMC-31 Testing ASTMC-143. Typesof ~ [7-%] [~ D Curing: I Methods: ASTM C-39 Fracture: A B C D REMARKS: Technician: Jeff Jedlicka FUGRO SOUTH INC. Reviewed By: SMH,,'rm Distribution: Preston Engineering - Timothy D. McMahon, P.E.