Report Date: 10/22/2015 Previously Reported: 09/30/2015
Project: Freeport Parkway North
Location: 188 Freeport Parkway northbound lane sidewalk
Client
REPORT
Material:
City of Coppell
REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Concrete
Date Sampled: 09/22/2015
Sampled By: Corbin, Rodney
By Order Of: Walter
Order Number: 1770
Number of
Specimens: 4
LAB NO: 193968
Test Method: See Below
TEST RESULTS Report No: 193968
Page 1 of 1
Maximum Compressive Average
Spec Age Tested Diameter Area Load Cure Strength Strength Tested
Nbr (date : days) (in) (W) (lbs) 'Break Type Loc (PSI) (PSI) By Comments
A 09/29/15 : 7 6.00 28.27 72,160 Type 3 Lab 2,550 2,550
B 10/20/15 : 28 6.00 28.27 107,160 Type 3 Lab 3,790 JR
C 10/20/15: 28 6.00 28.27 105,420 Type 3 Lab 3,730 3,760 JR
HOLD (see remarks) -
D
Type 1 Type 2 Type 3 Type 4 Type 5 Type 6
Specification CONFORMS
Strength: 3,600 psi @ 28 days
Slump: 3-5 Slump: 5.0 Inches Transported By: TXI
Air Content: 3-6 Air Content: 5.9% Source/Sampled At: Truck I Center
Mix Code: F8204 Plant: 141
Date Received: 09/23/2015 Truck/Ticket No: 5875 12988464
Curing Method: Standard
Time Sampled: 1:50 pm
Time Batched: 1:23 pm
Temp.: Ambient: 93°F Mix: 93°F
Unit Weight: 146.8 #/cu ft
Quantity Represented: 10 cu. yds. at 20 cu yds. placed of a 26 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Orig: City of Coppell (Coppell, TX) Attn: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, SET, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION