Loading...
ST0004-LR010726 ~ GEOT~'~-HNICAL, ENVIRONMENTAL AND MATERIALS ENF~EERS  DAL ; FORTWORTH HOUSTON AUSTIN LO, 'IEW 11050 Ables Ln., Dallas, Texas 75229 phone; (972) 488-8800 fax:(972) 488-8080 ---- - Concrete Compression Test Report Client: The City of Coppell Report Distribution: (1) The City of Coppell Project: Freeport Parkway Pavement Repair TMI Report No.: DC01-066-017 Report Date: 07/26/2001 Specifications Test Data Strength 4000 psi @ 28 Days Placement Date 07/12/2001 Slump 5 in max Sampled By Walter V. Kirby Air Content 3 % min 6 % max Weather Calm / Clear Concrete Temperature n/a Supplier/Mix Hanson/9636 Ambient Temperature n/a Air Content Method ASTM C-231-B Ticket Number: 799452 Time Batched: 2:00 PM Time Sampled: 2:30 PM Slump: 5 in Air Content: 6.0 % Unit Weight: n/a Concrete Temperature: 99° F Ambient Temperature: 102° F Yardage (c.y.): Placement Location: North bound lane (inside) at NE corner of Freeport & Airline Drive Sample Location: North bound lane (inside) at NE corner of Freeport & Airline Drive Set # Cyl~der Age, Max Load Area Strength Fracture Test Date (days) (lbs. force) (sq.in.) (psi'~ Type 1 07120101 07/19/2001 7 109780 28.27 3880 unbonded cap 11 0712010307120102 07/26/200107/19/2001 7~ 105150 28.27 ~ unbonded cap 14~ 118500 28.27 ~ unbonded cap 1 07120104 07/26/2001 14 ~, ,z ~"3~u z~.z/ --" unbonded cap 1 07120105 08/09/2001 28 1 07120106 08/09/2001 28 Normal cylinder size: 6" x 12" Field and laboratory tests by TMI a~ Standards: C31, C39, C138, C1~3, C172, C1064, and C617 or C1231. The results presented in this repo~ pe~ain only to ~e specific items tested. This report was produced for the exclusive use of ~e client. Any repr~u~ion of this repo~, or any pa~ therein, is sWctly prohibited without the express written consent of TMI.