ST0004-LR010726 (2) ~ GEOT, F~HNICAL, ENVIRONMENTAL AND MATERIALS EI~C~NEERS
DA, $ FORT WORTH HOUSTON AUSTIN LC /IEW
11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax,'(972) 488-8080
Concrete Compression Test Report
Client: The City of Coppell Report Distribution: (1) The City of Coppell
Project: Freeport Parkway Pavement
Repair
TMI Report No.: DC01-066-023
Report Date: 07/26/2001
Specifications Test Data
Strength 4000 psi @ 28 Days Placement Date 07/18/2001
Slump 5 in max Sampled By Zuhair Shubbar
Air Content 3 % rain 6 % max Weather Clear
Concrete Temperature n/a Supplier/Mix Hanson/9636
Ambient Temperature n/a Air Content Method ASTM C-231-B
......................... ~.~
Ticket Number: 819405 Time Batched: 12:13 pm Time Sampled: 12:55 pm
Slump: 7.25 in* Air Content: 8.0 %* Unit Weight: n/a
Concrete Temperature: 95° F Ambient Temperature: 96° F Yardage (c.y.): 20 of 50
Placement Location: Paving
Sample Location: North Freeport Parkway at East side
An asterisk (*) appears next to field data which does NOT meet specifications.
Age. Max Load Area Strength Fracture
Set # Cyl~der Test Date (days) (lbs. force) (sq.in.) (ps~ Type
I 07180101 07/25/2001 7 110810 28.27 3920 unbonded cap
I 07180102 07/25/2001 7 102810 28.27 3640 unbonded cap
I 07180103 08/01/2001 14
1 07180104 08/01/2001 14
1 07180105 08/15/2001 28
I 07180106 08/15/2001 28
Normal cylinder size: 6" x 12"
Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138. C143, C172, C1064, and C617 or C1231.
~ SCOTT M. PETT~T
~.-..... ......
TERRA-MAR, INC. p.[.
The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of
this report, or any part therein, is strictly prohibited without the express written consent of
Page 1 of l