_--- .- -' Concrete Compression Test Report
Client: The City of Coppell Report Distribution: (1) The City of Coppell
Project: Freeport Parkway Pavement
Repair
TMI Report No.: DC01-066-024
Report Date: 07/26/2001
Specifications Test Data
Strength 4000 psi @ 28 Days Placement Date 07/19/2001
Slump 5 in max Sampled By Zuhair Shubbar
Air Content 3 % rain 6 % max Weather Clear
Concrete Temperature n/a Supplier/Mix Hanson/9636
Ambient Temperature n/a Air Content Method ASTM C-231-B
Ticket Number: 819526 Time Batched: 3:15 pm Time Sampled: 4:10 pm
Slump: n/a Air Content: n/a Unit Weight: n/a
Concrete Temperature: 100° F Ambient Temperature: 99° F Yardage (c.y.): n/a
Placement Location: Paving
Sample Location: Station 8+50, North bound lane of Freeport Parkway
Age. Max Load Area Strength Fracture
Set # Cyl~¢ der Test Date (days) (lbs. force) (sq.in.) (ps~ Type
2 07190107 07/26/2001 7 114010 28.27 4030 unbonded cap
2 07190108 07/26/2001 7 125550 28.27 4440 unbonded cap
2 07190109 08/02/2001 14
2 07190110 08/02/2001 14
2 07190111 08/16/2001 28
2 07190112 08/16/2001 28
Normal cylinder size: 6" x 12"
Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231.
Supervisor was informed of high concrete temperature. ~-'¢~'*""~"-~-. ~.~ ~'1~
.... TTIT
TER~-MAR, INC,
The resul~ presented in this mpo~ pedain only to the specific items tested. This roped was produced for the exclusive use of the client. Any mpr~ucfion of
this repoA, or any paA therein, is strictly prohibited without the express written ~nsent of TMI.