FW Coppell Old Town Coppell Mels # 12-005-010050 VALMONT#163171-P1 SSP TL-10173Mr. Marvin, Can I get some clarifications on these questions? Thank you. Patrick Espinoza Estimator JRJ Paving, LP 1805 Royal Lane, Ste. 107 Dallas, Texas 75229 TEL: 214-466-8340 FAX: 214-466-8354 From: Mark Obarr [mailto:mark@melselectric.com] Sent: Monday, November 14, 2011 1:41 PM To: Patrick Espinoza; Marty Murphy Subject: FW: Coppell Old Town Coppell / Mels # 12-005-010050/ VALMONT#163171-P1 / SSP TL-10173 Have you been able to get an answer on this yet? Mark O'Barr Mels Electric L.P. Voice (972) 441-6208 Fax (972) 441-6394 6305 S. IH 45 PO Box 40 Wilmer, TX 75172 From: Mark Obarr Sent: Monday, November 07, 2011 2:35 PM To: 'Patrick Espinoza' Subject: FW: Coppell Old Town Coppell / Mels # 12-005-010050/ VALMONT#163171-P1 / SSP TL-10173 Can you get these question answered please Mark O'Barr Mels Electric L.P. Voice (972) 441-6208 Fax (972) 441-6394 6305 S. IH 45 PO Box 40 Wilmer, TX 75172 From: John Pipes [mailto:Johnp@s-steel.com] Sent: Monday, November 07, 2011 2:20 PM To: Mark Obarr Subject: Coppell Old Town Coppell / Mels # 12-005-010050/ VALMONT#163171-P1 / SSP TL-10173 Mark Please see the questions below from Valmont regarding the design of the signal poles for the project mentioned above. Let me know if you have any questions. Thank you John From: Clemens, Robert B. [mailto:robert.clemens@valmont.com] Sent: Monday, November 07, 2011 2:05 PM To: John Pipes Cc: Black, Shelly Subject: TL10173/ PO#243290 / VALMONT#163171-P1 John, Sheet TS-2 calls for all the poles to have T-bases, Astro-bracket mounted signals and vibration dampers. Sheet TS-3 has conflicting information. The notes on the left call for the poles to have a 36-A foundation, but the table with the pole numbers P1,P2, etc… have the appropriate foundations for a TXDOT pole. P1 is a 32’ mast arm and the table has its foundation as a 30-A, which would be correct per TXDOT> 1. Are these poles to be TXDOT? a. Your email to Mandy states the project engineer wants TXDOT poles but with modified hand hole to accommodate the decorative base b. If that is so, we will need clarification that a 30-A foundation is going to be ok. 2. Since they call for ASTRO-Brackets, should these be called out as type II or Type III mast arms? a. Are the arms MOD A? i. If so, do they know that a 32’ arm will be 31’ long due to the deletion of the end tenon? ii. Or do these need to be engineered 32’ long? 3. This was not quoted for any type of Vibration Damper. a. How should we proceed in light of this information? This order has been placed on hold pending receipt of the above requested information. The estimated mailing date for the print approval drawings will be 2 working days after we receive the required information. Please call if you have any questions or require further clarification. Thank you, Robert Clemens Senior Design Drafter Americas Lighting & Communications Structures Valmont Industries Valley, Nebraska Ph: 402-359-2201 ext. 3029 Fax: 402-359-4025 robert.clemens@valmont.com <mailto:robert.clemens@valmont.com> The information contained in this E-mail message and the documents accompanying this message are privileged and confidential, and may be protected from disclosure. Please be aware that any use, printing, copying, disclosure or dissemination of this communication may be subject to legal restriction or sanction. If you think that you have received this E-mail message in error, please reply to the sender. For more information about Valmont Industries, Inc., please visit our web site at www.valmont.com