Loading...
FW Old Town Coppell Grading questionsKeith, Please see the email below and attachment for my response to Kirk’s questions. Thanks Dan Prendergast E.I.T. URBAN PLANNING + DESIGN GROUP Freese and Nichols, Inc. 1701 N. Market St., Suite 500 Dallas, Texas 75202 214-217-2216 www.freese.com <http://www.freese.com/> From: Dan Prendergast Sent: Thursday, February 09, 2012 3:50 PM To: 'Kirk' Cc: 'Tad Larson'; 'Tery Chapman'; 'Marty Murphy'; 'JR Marriott' Subject: RE: Old Town Coppell Grading questions Kirk, Please see the attached exhibit with elevation call outs for the intersection of Houston St and Coppell Rd. On the PI points, there are 2 PI points in the alignment and those points are correct. I highlighted the leaders in red so you could better see what they are pointing to. As for 6+50 on Houston: The points called out in the cross section are the top of curb behind the ADA ramp landing. Points 34 and 35 show the left EP elevations around the ramp and points 41 and 40 show the right EP elevations around the ramp. Your assumptions are correct for EP elevations at the north side of the ramp landing. Let me know if you need anything else Thanks Dan Prendergast E.I.T. URBAN PLANNING + DESIGN GROUP Freese and Nichols, Inc. 1701 N. Market St., Suite 500 Dallas, Texas 75202 214-217-2216 www.freese.com <http://www.freese.com/> From: Kirk [mailto:kirk@kazsurveying.com] <mailto:[mailto:kirk@kazsurveying.com]> Sent: Thursday, February 09, 2012 1:34 PM To: Dan Prendergast Cc: 'Tad Larson'; 'Tery Chapman'; 'Marty Murphy'; 'JR Marriott' Subject: Old Town Coppell Grading questions Dan: I have been tasked with staking the curb on Houston Street from the intersection of Main, East to the intersection at South Coppell. I have questions regarding the following data. 1. At the intersection of S. Coppell & Houston, (sheet PV-7) there is a PI called at Station 9+67.29, with coordinates given. The coordinates appear to be more correct. It appears to be at Station 9+96.79 -42.47’-RT. 2. At the same intersection. On sheet PV-7, I’m having trouble with the following: the PVI data from the profile VS. the Point table calls, and digital station data: PVI Station 9+97.29; when projected to the proposed Left and Right Curb lines, follows and intersects the gutter line, but is delineated as a top of curb in the profile view. PVI Station 9+91.85; - when projected to the proposed Left and Right Curb lines, follows and intersects the gutter line, but is delineated as a top of curb in the profile view. PVI Station 9+86.79; - when projected to the proposed Left and Right Curb lines, follows and intersects the gutter line, but is delineated as a top of curb in the profile view. The Left Curb slope, when calculated between PVI station 9+68.08 to PVI Sta 9+86.79 results in a slope of 4.9% , The Right Slope at 2.9% The Profile calls 4.4% & 2.6% respectively. 3. The section for Station 6+50 Gives data for LT. TBOC-516.71, RT-TBOC-516.61. that section appears to be within an ADA ramp. Am I to assume that data should be LT- EP=516.21 & RT=-516.11 As far as the Houston/ South Coppell Intersection, could I get an exhibit with top-back of curb-elevation clarified on the above stations if correct, or updated data if not, as well as Top-of Curb- elevation and station data for all points of curvature and tangency from station 9+68 to the end? Regards, Kirk Ross, EIT KAZ SURVEYING 1720 Westminster Street Denton, TX 76210 Office: 940-382-3446 Fax: 940-382-3447 Email: kirk@kazsurveying.com <mailto:aaron@kazsurveying.com> ***Order land surveys online at www.kazsurveying.com <http://www.kazsurveying.com/> *** Please consider the environment before printing this message. ________________________________ This electronic mail message is intended exclusively for the individual or entity to which it is addressed. This message, together with any attachment, may contain the sender's organization's confidential and privileged information. The recipient is hereby notified to treat the information as confidential and privileged and to not disclose or use the information except as authorized by sender's organization. Any unauthorized review, printing, retention, copying, disclosure, distribution, retransmission, dissemination or other use of, or taking of any action in reliance upon, this information by persons or entities other than the intended recipient is prohibited. If you received this message in error, please immediately contact the sender by reply email and delete all copies of the material from any computer. Thank you for your cooperation. 牬晴‰਍屻尪瑨汭慴㉧㐴㰠㩯㹰ൽ笊⩜桜浴瑬条㔲′⼼㩯㹰ൽ笊⩜桜浴瑬条㔱‶⼼灳湡紾桜浴牬晴素桜浴牬晴‰਍屻尪瑨汭慴㥧′⼼㹢屽瑨汭瑲⁦屽瑨汭瑲て尠瑨汭瑲屦慰絲桜浴牬晴ര尊瑨汭瑲⁦灜牡਍桜浴牬晴‰਍屻尪瑨汭慴㝧′⼼㹰ൽ笊⩜桜浴瑬条‰灜牡素਍屻尪瑨汭慴㙧‴瀼挠慬獳∽獍乯牯慭≬猠祴敬∽整瑸愭瑵獯慰散渺湯≥紾桜浴牬晴笠桜浴牬晴‰਍屻尪瑨汭慴ㅧ㠴㰠灳湡猠祴敬∽潦瑮猭穩㩥⸹瀰㭴潣潬㩲ㄣ㑆㜹≄紾桜浴牬晴笠桜浴牬晴‰ 㜱㄰١最�\潸ᐄ砀ᐕreferences a maximum grade in a subdivision to be 10% but was not clear if that included the driveways. We were planning on limiting our maximum grades to 14%. The driveways are only 6 feet long. Thanks. Mike Glenn, P.E. Glenn Engineering Corp. TBPE Firm F-303 HUB #1752575193300/469711 105 Decker Court, Suite 910 Irving, Texas 75062 972-717-5151(o) 972-672-2450(m)