PA0101-LR010719 CONCRETE COMPRESSIVE STRENGTH TEST ~1.,~
~lhl~, [NC,
8901 Carpenter Frwy., Suite #100
Report Number: 94011093.0025 _ ~,~'"'~~'~" f ~ Dallas, Texas 75247
Service Date: July 19, 2001 (214) 63O-lOlO
Client: City of Coppell - Parks & Recreation Repo~,~ate: J~j~27, 20~11¢I
Attn: Brad Reid Proj~ll~t: Andrew BrownJ~l~rk East
732 DeForest ~' Moore RoadJ
Coppell TX 75019 t Coppell, T~'as
P~)ject Number:~4011093
Material Information ~aml31e I~rmation
Specified Strength: 3000 psi (~ 28 Days S~e: 8:18am Date Cast:July 19, 2001
Technician: Barry Cuble
Batch Time: 8:00am Plant: 41 Weather Conditions: Sunny, mild
Supplier: TXI Accumulative Yards: 30
Truck No: 451 Ticket No: 2941589 Placement Method: Pump
Mix I.D. No.: 8272 Sample Locations: 10' N of lightpole
Placement Location: Paving: NW of field, sidewalk: E of field
Field Test Data
Test Result Specification Test Method
Slump, inches: 6.00 3-5 ASTM C-143
Air Content, %: 5.2 3-6 ASTM C-231
Concrete Temperature, o F: 91 ASTM C1064
Ambient Temperature, o F: 81 ASTM C-1064
Plastic Unit Weight, pcf:
Laboratory Test Data
Age at Maximum Compressive
Set Specimen Diameter Area Date Test Lo~d ~.".;,,u[I.
No. ID (inches) (sq. inches) Tested (days) ~,~"~) (psi)
1 1 6.00 28.27 07/26,2001 f 101,500 3,590
1 2 6.00 28.27 07/26,2001 ~,~ 1~
' ~ 3,740
1 3 08/16/2001 28
1 4 08/16/2001 28
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
ASTM C-31, C-39, C-172, C-1231
Technician: Barry Cuble
Report Distribution:
(1) city of Coppell- Parks & Recreation
(1) TLB Construction Reviewed by:
(1) city of Coppell - Constr. Insp. - '"Eric J. Clevelar~l, P.E.
Senior Project Engineer
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicsted above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1