Loading...
Estates DC-CS 990121CASE NO.: CITY OF COPPELL PLANNING DEPARTMENT STAFF REPORT PD-175, ESTATES OF DENTON CREEK P & Z HEARING DATE: C.C. HEARING DATE: LOCATION: SIZE OF AREA: CURRENT ZONING: REQUEST: APPLICANT: January 21, 1999 February 9, 1999 Along the north side of Sandy Lake Road, approximately 1,800 feet east of N. MacArthur Boulevard. ~ 28.2121 acres of property (55 residential lots). SF-12 (Single Family-12) PD-SF-9 (Planned Development, Single Family-9) Prospective Purchaser: The Holmes Builders,Inc. 1406 Halsey Way Suite 100 Carrollton TX. 75007 (972) 242-1770 Fax: (972) 242-2931 Engineer: N. D. Maier, Engrs. Mike Daniel 8080 Park Ln. Suite 600 Dallas, TX. 75231 (214) 739-4741 Fax: (214) 739-5961 HISTORY: There has been no recent zoning/subdivision activity on the parcel in question although filling of the land has been occ ~urring on an infrequent basis over the last two-three years. TRANSPORTATION: Sandy Lake Road is proposed to be a C4D/6, four-lane divided thoroughfare in a six-lane right-of-way (110 feet). Today it is an unimproved two-lane asphalt roadway. SURROUNDING LAND USE & ZONING: North- vacant floodplain; Carrollton zoning South -vacant; PD-114 (SF-7) East - vacant and scattered housing; Carrollton zoning and SF-12 West -landscape nursery; "R', Retail Item # 6 COMPREHENSIVE PLAN: The Comprehensive Plan shows the property as suitable for residential and neighborhood retail (Sandy Lake frontage). DISCUSSION: This proposal generally conforms to the guidelines outlined in the Comprehensive Plan. The density of roughly 2.5 units per gross acre fits the density pattern to the north and west of this tract, and is an appropriate use at this location. Although the Plan also calls for neighborhood retail in the vicinity of this proposal, the lack of substantial frontage along Sandy Lake Road negates any retail being developed upon this parcel. Of concern to staff is access to the property, especially if flooding occurs. The single access point to Sandy Lake Road is in the 100-year floodplain. The developer must prov. idea roadway that is not in the floodplain. Any proposed modifications to Sandy Lake Road will have to be approved by the Engineering Department. From a health, safety and welfare perspective, the Fire Department can not support single access into this residential subdivision. The erosive banks of Denton Creek may require erosion control along the creek to be maintained by the Homeowners Association or the property owners. No fill will be allowed in the floodplain until a flood study is submitted and approved by FEMA. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: Because of the concerns we have regarding the floodplain and the access to this property, staff must recommend denial of this project at the present time. When better access can/has been procured, and we have assurance that the flooding concerns with Sandy Lake Road have been adequately addressed, we would encourage a resubmittal. Until that happens we must recommend denial of this application. ALTERNATIVES: ATTACHMENTS: 1) Recommend approval of the request 2) Recommend disapproval of the request 1) Zoning Exhibit 2) Tree Survey 3) Landscape Plan 4) Departmental Comments Item # 6 DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: PD-175, Estates of Denton Creek, a zoning change request from "SF-12' to "PD-SF-9", to allow the development of a 55 residential lot subdivision on 28.21 acres of property, located along the north side of Sandy Lake Road, approximately 1,800' east of N. MacArthur Blvd., at the request of Nathan D. Maier Consulting Engineers, Ina DRC DATE: December 29, 1998 and January 7, 1999 CONTACT: Mike Martin, P.E., Assistant City Engineer (972-304-3679) Due to the erosive banks of Denton Creek, erosion control may be required along Denton Creek to be maintained by the Homeowners Association or the property owners. The single access point to Sandy Lake Road is in the 100-year floodplain. Access to the subdivision should be provided by a roadway which is not in the 100-year floodplain. A drainage swale exists through the Northwest portion of the property which is shown on the FEMA map to be in the 100-year floodplain. The location of this swale and/or drainage improvements/system may affect the ability to develop the lots in thia area. DEVELOPMENT REVIEW COMMI23/'EE FIRE PREVENTION COMMENTS ITEM: PD.17$, DENTON CREEK SUBDM$10N DRC DATE: .IANUARY CONTACT: TRA VIS CRUMP, FIRE MARSHAL. (214) 304-3503 The Coppell Fire Department can not support this development as shown. ways in and out of the subdivision is required. At least two 2. The street into the subdivision exceeds the cul-de-sac maximum length. 10:57 CITY~COPPELL ~ CITY OF COPPELL ~ N0.013 I I I II IIII III I .11 . I I DEVELOPMENT REVIEW COMMITIF DRC DATE: Decemb~ 29, 1998 and Immanj 7,1999 CONTACT: Brad Reid, Park Plam~s mul Lemlscape IIII I1! · I I I COMMENT STA Tt!$: _~ PRELDt4INAR Y The d~oeloper shosld be aware that this d~v#1opmmt is impacted b~ Developmmt ordinance stiimlati#g a fee o]' $1,285.00 per dwelling uit A Tree S~rv~ ~ required D~C/229~c