Loading...
Enclaves-CS 950216 February 16, 1995 Ms. Teri Jones Dowdey, Anderson & Associates Inc. 16250 Dallas Parkway Suite 100 Dallas, Texas 75248 RE: The Enclaves on the Parkway Construction Plans Dear Ms Jones: The City of Coppell has received and reviewed the referenced plans and has the following comments to offer: 1. Provide an 8' wide brick paver band as per the City's Streetscape Plan. 2. Do not discharge stormwater into Parkway Blvd.; regrade street or provide inlets. Also, show direction of flow in Parkway Blvd. 3. Low point inlets shall be a minimum of 10' and shall have minimum 21" pipe as per the City of Dallas Drainage Design Manual. 4. Revise grading plan for lots 2-7 to insure adequate drainage. 5. Address the following comments made by Howard Pafford, Utilities Superintendent. If you have any questions please contact him at 304-3545. a. Bore for water line shall be a dry bore. b. Provide two 45 degree bends for waterline as indicated on water and sewer plan. c. Review and revise general notes to show the latest design criteria. 6. Show all proposed sidewalks with note stating to either be built by developer or home builder. There are various other minor comments throughout these plans. Once these comments have been addressed, the revised set of plans should be resubmitted to the City for review. If you should have any questions concerning these comments, please feel free to contact me at your convenience. Michael A. M/~rtin, E.I.. Graduate Engineer