Loading...
Fairways-CS 931111Falkofske Engineering, Inc. 1414 We~t Randol Mill Road, Suit~ 201 Arlington, Texa~ 76012 Metro (817) 261-8300 Fax (817) 261-0800 November 11, 1993 Mr. Tim Clancy Metroplex Retaining Walls, Inc. 11016 S. Pipeline Road Euless, Texas 76040 Re: Revised Retaining Wall Designs Fairways at Riverchase Coppell, Texas Falkofske Engineering, Inc. Job No. 113.93 Dear Mr. Clancy: As you know we have revised the design of the retaining walls for the above project: The .n. ew plans and specifications call for clean gravel behind the retaining walls. It is my understanding that Metroplex Retaining Walls, Inc. has, in some cases, on this project used broken concrete instead of the gravel as specified. It is my opinion that the broken concrete pieces with fine sands are an acceptable alternative to the gravel which was specified. The reason for this is that the broken concrete is more angular in nature and will provide a higher angle of internal friction than will the gravel. Because of this higher angle of internal friction, the broken concrete will produce less backf'fll pressure on the retaining walls which is desirable. Sincerely, ~ _./~ .. _ ~ ..... ~..r~.. .... 3t-'"'..~.~-nt Ti '~a6~y John F, tflkofske,. P.E. ~ : ~ .~ ~ D~. No. 11393.2 ~...:.........................:..~