Loading...
ST0502B- LR151119RLLIAnCE GGEOTECHnICPIL GROUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C15-0812 Report Date: 11/19/2015 Previously Reported: 10/30/2015 Project: Freeport Parkway North Location: Wall floor, Sampled; Panel 4, Wall 8 Client: REPORT Material: City of Coppell REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST Concrete TEST RESULTS Maximum Compressive Spec Age Tested Diameter Area Load Cure Strength Nbr (date : days) (in) (int) (Ibs) Break Type Loc (PSI) Date Sampled: 10/21/2015 Sampled By: Smith, Charles By Order Of: Walter Order Number: 1770 Number of Specimens: 4 LAB NO: 195851 Test Method: See Below Report No: 195851 Page 1 of 1 Average Strength Tested (PSI) By Comments A 10/28/15: 7 6.00 28.27 112,545 Type 3 Lab 3,980 3,980 JR B 11/18/15: 28 6.00 28.27 144,670 Type 3 Lab 5,120 JR C 11/18/15: 28 6.00 28.27 140,090 Type 3 Lab 4,950 5,040 JR D HOLD (see remarks) - Irvll'ij Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification CONFORMS Strength: 3,600 psi @ 28 days Slump: 3-5 Slump: 5.0 Inches Transported By: LMC Air Content: 3-6 Air Content: 4.3% Source/Sampled At: Truck / Center Mix Code: 1701 Plant: 952 Date Received: 10/22/2015 Truck/Ticket No: 5023 / 62988451 Curing Method: Standard Time Sampled: 5:30 pm Time Batched: 4:23 pm Temp.: Ambient: 83°F Mix: 92°F Unit Weight: 145.8 #/cu ft Quantity Represented: 9.5 cu. yds. at 9.5 cu. yds, placed of a 37.0 cu. yd, total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Ong: City of Coppell (Coppell, -TX) Attn: Mr Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION