Loading...
ST0502B- LR151207 (2)RLLIfinCE GGEOTECHI'IICRL GROUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C15-0812 Date Sampled: 11/06/2015 Report Rate: 12/07/2015 Previously Reported: 11/16/2015 Sampled By: Goldy, Dwight Project: Freeport Parkway North By Order Of: Walter Location: Box Culvert walls only, Sampled; Paving south wall west end at Order Number: 1770 Station 16+50 Number of Client City of Coppell Specimens: 4 REPORT REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 197036 Material: Concrete Test Method See Below TEST RESULTS Report No: 197036 Spec Nbr A B C D Type 1 Specification Strength: 4,000 psi @ 28 days Slump: Air Content: Type 2 Type 3 Type 4 Type 5 Type 6 CONFORMS Slump: 4,0 Inches Transported By: LMC Air Content: 5.5% Source/Sampled At: Truck I Center Mix Code: 1701 Plant: 956 Date Received: 11/07/2015 Truck/Ticket No: 7060 / 63096559 Curing Method: Standard Time Sampled: 1:48 pm Time Batched: 12:48 pm Temp.: Ambient: 70°F Mix: 75°F Unit Weight: 147.7 #/Cu ft Quantity Represented: 8 cu. yds. at 8 cu. yds. placed of a 24 cu, yd. total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Orig: City of Coppell (Coppell, FX) Attn: Mr. Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, SE/T, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF 11 IE QUALII ES OF APPARENTLY IDENTICAL. OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Page 1 of 1 Maximum Compressive Average Age Tested Diameter Area Load Cure Strength Strength Tested (date : days) (in) (int) (lbs) Break Type Loc (PSI) (PSI) By Comments 11/13/15: 7 6.00 2827 122,035 Type 3 Lab 4,320 4,320 JR 12/04/15: 28 6.00 28.27 152,710 Type 3 Lab 5,400 12/04/15: 28 6.00 28.27 155,745 Type 3 Lab 5,510 5,450 HOLD (see remarks) - Type 1 Specification Strength: 4,000 psi @ 28 days Slump: Air Content: Type 2 Type 3 Type 4 Type 5 Type 6 CONFORMS Slump: 4,0 Inches Transported By: LMC Air Content: 5.5% Source/Sampled At: Truck I Center Mix Code: 1701 Plant: 956 Date Received: 11/07/2015 Truck/Ticket No: 7060 / 63096559 Curing Method: Standard Time Sampled: 1:48 pm Time Batched: 12:48 pm Temp.: Ambient: 70°F Mix: 75°F Unit Weight: 147.7 #/Cu ft Quantity Represented: 8 cu. yds. at 8 cu. yds. placed of a 24 cu, yd. total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Orig: City of Coppell (Coppell, FX) Attn: Mr. Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, SE/T, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF 11 IE QUALII ES OF APPARENTLY IDENTICAL. OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.