ST0502B- LR151207 (3)ALLIWYCE GEOTECHNICML GRCUF Acct ID: 1770 Report Date: 12/07/2015 Project: Freeport Parkway North Location: Rebar Inspection Client: City of Coppell REPORT. Reinforcing Steel Inspection Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 File No: C15-0812 Date Sampled: 12/04/2015 Sampled By: Eli Avila By Order Of: Walter Order Number: 1770 LAB NO: 198708-1 TEST RESULTS Report No: 198708-1 Page 1 of 1 We visually inspected the reinforcing steel of traffic signal pier. Our inspection included verifying the proper size of the reinforcing steel including diameter, length, bends and anchorage, and the grade and the location of the bars including spacing and cover. We also verified proper splicing, checked stability of tying, and checked the reinforcing steel for excessive rust deposits. Other: Traffic signal Pier #P-4, 10-#8's at w/#3 stirrups at 12" OC Type one (36" diameter) • Drawing Date: 1/25/2015 • Details Referenced: Sheets #88 - #92 Orig: City of Coppell (Coppell, TX) Attn: Mr. Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C, Kakara, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. RLLIf11'ICE CtEOTKHYICRL GROUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C15-0812 Date Sampled: 12/04/2015 Report Date: 12/07/2015 Sampled By: Eli Avila Project: Freeport Parkway North By Order Of: Walter Location: Rebar Inspection Order Number: 1770 Client: City of Coppell REPORT. Reinforcing Steel Inspection LAB NO: 198708-2 TEST RESULTS Report No: 198708-2 Page 1 of 1 We visually inspected the reinforcing steel on the retaining wall. Our inspection included verifying the proper size of the reinforcing steel including diameter, length, bends and anchorage, and the grade and the location of the bars including spacing and cover. We also verified proper splicing, checked stability of tying, and checked the reinforcing steel for excessive rust deposits. Wall: Retaining wall B at Station 0+00 to 0+63. U bars at 15" OC w/#5's vertical and horizontal. Type one. • Drawing Date: 1/23/2015 • Details Referenced: Page 2 general notes and Pages 35 and 37. Orig: City of Coppell (Coppell, TX) Attn: Mr. Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.