ST0502B- LR151215 (2)AuiAncE
(� G GEOTECHf1109L
GROUP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812 Date Sampled: 12/07/2015
Report Date: 12/15/2015 Sampled By: Selman, Mario
Project: Freeport Parkway North By Order Of: Walter
Location: Freeport Parkway and Sandy Lake, Sampled; Station 3+59.46 Order Number: 1770
Freeport Parkway and Sandy Lake inlet box
Client:
REPORT:
Material:
Spec
Nbr
A
B
C
D
City of Coppell
REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Concrete
TEST RESULTS
Number of
Specimens: 4
LAB NO: 198851
Test Method: See Below
Report No: 198851
Page 1 of 1
Average
Strength Tested
(PSI) By Comments
4,530 JR
HOLD (see remarks) -
I
Type 1 Type 2 Type 3 Type 4 Type 5 Type 3
Specification
Strength: 4,200 psi @ 28 days
Slump: 3-5 Slump: 4.5 Inches Transported By: Redi-Mix
Air Content: 3-6 Air Content: 4.6% Source/Sampled At: Truck / Center
Mix Code: 1 OM21524 Plant: P259
Date Received: 12/08/2015 Truck/Ticket No: 1235 / 25201905
Curing Method: Standard
Time Sampled: 1:30 pm
Time Batched: 12:46 pm
Temp.: Ambient: Mix: 68°F
Unit Weight: 146.4 #/cu ft
Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 10 cu. yd, total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138, Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Orig: City of Coppell (Coppell, TX) Attn: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C, Kakara, SE/T, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
T HE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION
Maximum
Compressive
Age Tested
Diameter
Area
Load
Cure
Strength
(date : days)
(in)
(int)
(Ibs)
Break Type Loc
(PSI)
12/14/15 ; 7
6.00
28.27
128,150
Type 3 Lab
4,530
01/04/16:28
6.00
28.27
Lab
01/04/16:28
6.00
28.27
Lab
Number of
Specimens: 4
LAB NO: 198851
Test Method: See Below
Report No: 198851
Page 1 of 1
Average
Strength Tested
(PSI) By Comments
4,530 JR
HOLD (see remarks) -
I
Type 1 Type 2 Type 3 Type 4 Type 5 Type 3
Specification
Strength: 4,200 psi @ 28 days
Slump: 3-5 Slump: 4.5 Inches Transported By: Redi-Mix
Air Content: 3-6 Air Content: 4.6% Source/Sampled At: Truck / Center
Mix Code: 1 OM21524 Plant: P259
Date Received: 12/08/2015 Truck/Ticket No: 1235 / 25201905
Curing Method: Standard
Time Sampled: 1:30 pm
Time Batched: 12:46 pm
Temp.: Ambient: Mix: 68°F
Unit Weight: 146.4 #/cu ft
Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 10 cu. yd, total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138, Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Orig: City of Coppell (Coppell, TX) Attn: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C, Kakara, SE/T, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
T HE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION
RLLIfinCE
GGEOTKHnICRL
GROUP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Report Date: 12/15/2015
Project: Freeport Parkway North
Location: Misc. Concrete
Client City of Coppell
REPORT. REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
TEST RESULTS
Set: 1 of 2 Material: Concrete
Location: Wall B retaining wall, Station 0+00 to 0+69.34
Date Sampled: 12/04/2015
Sampled By: Avila, Eli
By Order Of: Walter
Order Number: 1770
LAB NO: 198708
Test Method: See Below
Report No: 198708
Page 1 of 2
Number of Specimens: 4
Average
Strength Tested
(PSI) By Comments
4,480 JR
Type 6
HOLD (see remarks) -
Specification
Strength: 3,600 psi @ 28 days
Slump: 3-5 Slump: 4.0 Inches Transported By: LMC
Air Content: 3-6 Air Content: 2.5% Source/Sampled At: Truck / Center
Mix Code: 1701 Plant: 956
Date Received: 12/05/2015 Truck/Ticket No: 9102 163097101
Curing Method: Standard
Time Sampled: 11:34 am
Time Batched: 10:34 am
Temp : Ambient: 52°F Mix: 64°F
Unit Weight: 152 4 #/cu ft
Quantity Represented: 9.5 cu. yds. at 9.5 cu. yds placed of a 17.0 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Orig: City of Coppell (Coppell, TX) Attn: Mr. Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Al- 6,
Perry C. Kakara, SET, CME Department Manager
THIS REPORI APPLIES ONLY TO THES rANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
I HE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT 10 BE REPRODUCED WITHOUT WRITTEN PERMISSION.
Maximum
Compressive
Spec
Age Tested
Diameter
Area
Load Cure
Strength
Nbr
(date : days)
(in)
(int)
(Ibs) Break Type
Loc
(PSI)
A
12/11/15 : 7
6.00
2827
126,785 Type 3
Lab
4,480
B
01/01/16 : 28
6.00
28.27
Lab
C
01/01/16:28
6.00
28.27
Lab
Type 1
Type 2 Type 3
Type 4 Type 5
Number of Specimens: 4
Average
Strength Tested
(PSI) By Comments
4,480 JR
Type 6
HOLD (see remarks) -
Specification
Strength: 3,600 psi @ 28 days
Slump: 3-5 Slump: 4.0 Inches Transported By: LMC
Air Content: 3-6 Air Content: 2.5% Source/Sampled At: Truck / Center
Mix Code: 1701 Plant: 956
Date Received: 12/05/2015 Truck/Ticket No: 9102 163097101
Curing Method: Standard
Time Sampled: 11:34 am
Time Batched: 10:34 am
Temp : Ambient: 52°F Mix: 64°F
Unit Weight: 152 4 #/cu ft
Quantity Represented: 9.5 cu. yds. at 9.5 cu. yds placed of a 17.0 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Orig: City of Coppell (Coppell, TX) Attn: Mr. Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Al- 6,
Perry C. Kakara, SET, CME Department Manager
THIS REPORI APPLIES ONLY TO THES rANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
I HE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT 10 BE REPRODUCED WITHOUT WRITTEN PERMISSION.
` ^ RLLIHfICE
GEOTECHf1109L
Y WouP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Report Date: 12/15/2015
Project: Freeport Parkway North
Location: Misc. Concrete
Client: City of Coppell
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Date Sampled: 12/04/2015
Sampled By: Avila, Eli
By Order Of: Walter
Order Number: 1770
LAB NO: 198708
Test Method- See Below
TEST RESULTS Report No: 198708
Page 2 of 2
Set: 2 of 2 Material: Concrete
Location: Traffic signal Pier P-4 at Station 0+78
Specification
Strength: 4,000 psi @ 28 days
Slump: 3-5
Air Content: 0.5-2.5
Date Received:
12/05/2015
Curing Method:
Maximum
Time Sampled:
Compressive
Spec
Age Tested
Diameter
Area Load
Cure
Strength
(PSI)
Nbr
(date : days)
(in)
(int) (Ibs)
Break Type
Loc
A
12/11/15: 7
6.00
28.27 146,880
Type 3
Lab
5,190
B
01/01/16:28
6.00
28.27
Lab
C
01/01/16:28
6.00
28.27
Lab
D
� I t�i
lu-
Type 1 Type
2 Type 3
Type 4
Type 5
Specification
Strength: 4,000 psi @ 28 days
Slump: 3-5
Air Content: 0.5-2.5
Date Received:
12/05/2015
Curing Method:
Standard
Time Sampled:
1:10 pm
Time Batched:
12:18 pm
Temp.: Ambient:
60°F Mix: 68°F
Slump: 3 0 Inches
Air Content: 2.0%
Mix Code: 1701
Number of Specimens: 4
Average
Strength Tested
(PSI) By Comments
5,190 JR
HOLD (see remarks) -
Type 6
Transported By: LMC
Source/Sampled At: Truck I Center
Plant: 956
Truck/Ticket No: 1407 163097103
Quantity Represented: 5 cu. yds. at 5 cu. yds, placed of a 5 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Orig: City of Coppell (CoppelI, TX)Attn: Mr. Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C• Kakara, SET, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATEDANU TO tHEsAMf'LE(S)Tr-SIE17AND1OR OPISERVEOA.NDARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCF,DUWS, N0I4 C)o THEY REPRESENTAN ONGOING OUWTYASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR 1 HE EXCLUSIVE USE OF THE ADDRESSED rl if NI ANT) ARC NOT 10 BF RL PRCrJUCEl] N7VTHC)Ul' wRITrEN PERMISSION.
FlLLIHfICE
GGEOTECHnlCRL
GROUP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812 Date Sampled: 11/12/2015
Report Date: 12/15/2015 Previously Reported: 11/23/2015 Sampled By: Douglas, Joseph
Project: Freeport Parkway North By Order Of: Walter
Location: Purpose side drain multiple box culvert, Line A at Station 16+50 Order Number: 1770
top
Client: City of Coppell
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 197476
Test Method: See Below
TEST RESULTS Report No: 197476-R
Page 1 of 2
Set: 1 of 2 Material: Concrete Number of Specimens: 4
Location: East right lane at Station 11+87.10
Maximum Compressive Average
Spec Age Tested Diameter Area Load Cure Strength Strength Tested
Nbr (date : days) (in) (in 2) (lbs) Break Type Loc (PSI) (PSI) By Comments
A 11/19/15: 7 6.00 28.27 101,760 Type 3 Lab 3,600 3,600 JR
B 12/10/15: 28 6.00 2827 126,700 Type 3 Lab 4,480
C 12/10/15: 28 600 28.27 128,985 Type 3 Lab 4,560 4,520
D �_ i.
HOLD (see remarks) -
�-�`,
Type 1 Type 2 Type 3 Type 4 Type 5 Type 6
Specification CONFORMS
Strength: 4,000 psi @ 28 days
Slump: 3-5 Slump: 3.5 Inches Transported By: LMC
Air Content: 3-6 Air Content: 5.5% Source/Sampled At: Truck / Center
Mix Code: 1701 Plant: 956
Date Received: 11/13/2015 Truck/Ticket No: 6037 163096717
Curing Method: Standard
Time Sampled: 11:50 am
rime Batched: 11:00 am
Temp.: Ambient: 70°F Mix: 80°F
Unit Weight: 148.3 #/cu ft
Quantity Represented: 8 cu. yds. at 8 cu. yds. placed of a 114 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Orig: City of Coppell (Coppell, TX) Attn: Mr. Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, SET, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND To THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
„RLLIAfICE
GEOTECFinICRL
GROUP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812 Date Sampled: 11/12/2015
Report Date: 12/15/2015 Previously Reported: 11/23/2015 Sampled By: Douglas, Joseph
Project: Freeport Parkway North By Order Of: Walter
Location: Purpose side drain multiple box culvert, Line A at Station 16+50 Order Number: 1770
top
_Client: City of Coppell _ ---
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 197476
Test Method: See Below
TEST RESULTS Report No: 197476-R
Page 2 of 2
Set: 2 of 2 Material: Concrete
Location: Left lane at Station 13+14.10
Spec
Nbr
A
B
C
D
Number of Specimens: 4
Type 1
Specification
Strength: 4,000 psi @ 28 days
Slump: 3-5
Air Content: 3-6
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 4.5 Inches
Air Content: 3.0%
Mix Code: 1701
Date Received: 11/13/2015
Curing Method: Standard
Time Sampled: 5:05 pm
"Time Batched: 4:20 pm
Ternp.: Ambient: 60°F Mix: 85°F
Unit Weight: 147.9 #/cu ft
Quantity Represented: 8 cu. yds. at 88 cu yds. placed of a 114 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and 0138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Comments
HOLD (see remarks) -
Transported By: LMC
Source/Sampled At: Truck I Center
Plant: 956
Truck/Ticket No: 1403 163096731
Ong City of Coppell (Coppell, TX) Attn: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, SE/T, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
Maximum
Compressive
Average
Age Tested
Diameter
Area
Load
Cure
Strength
Strength
Tested
(date : days)
(in)
(inz)
(Ibs)
Break Type
Loc
(PSI)
(PSI)
By
11/19/15 :7
6.00
28.27
131,300
Type 3
Lab
4,640
4,640
JR
12/10/15: 28
6.00
28.27
160,505
Type 3
Lab
5,680
JR
12/10/15: 28
6.00
28.27
165,250
Type 3
Lab
5,840
5,760
JR
Type 1
Specification
Strength: 4,000 psi @ 28 days
Slump: 3-5
Air Content: 3-6
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 4.5 Inches
Air Content: 3.0%
Mix Code: 1701
Date Received: 11/13/2015
Curing Method: Standard
Time Sampled: 5:05 pm
"Time Batched: 4:20 pm
Ternp.: Ambient: 60°F Mix: 85°F
Unit Weight: 147.9 #/cu ft
Quantity Represented: 8 cu. yds. at 88 cu yds. placed of a 114 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and 0138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Comments
HOLD (see remarks) -
Transported By: LMC
Source/Sampled At: Truck I Center
Plant: 956
Truck/Ticket No: 1403 163096731
Ong City of Coppell (Coppell, TX) Attn: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, SE/T, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
RLLIfinCE
��•.G GE0TECNfI1CRL
� CROUP
Consulting Engineering " Geotechnical Engineering'' Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Report Date: 12/15/2015 Previously Reported: 11/20/2015
Project: Freeport Parkway North
Location: Misc. Concrete
Client:
City of Coppell
REPORT:
REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Material:
Concrete
Spec
Age Tested
Diameter
Area
Nbr
(date : days)
(in)
(in')
A
11/19/15:7
6.00
28.27
B
12/10/15:28
6.00
28.27
C
12/10/15:28
6.00
28.27
D
4,040
JR
149,250
TEST RESULTS
Date Sampled: 11/12/2015
Sampled By: Reyes, Jason
By Order Of: Walter
Order Number: 1770
Number of
Specimens: 4
LAB NO: 197478
Test Method: See Below
Report No: 197478R
Page 1 of 1
Maximum
Compressive
Average
Load
Cure
Strength
Strength Tested
(lbs)
Break Type
Loc
(PSI)
(PSI)
By Comments
114,200
Type 3
Lab
4,040
4,040
JR
149,250
Type 3
Lab
5,280
JR
144,610
Type 3
Lab
5,110
5,200
JR
Type 1
Specification
Strength: 3,600 psi @ 28 days
Slump: 3-5
Air Content: 3-6
HOLD (see remarks) -
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 4.25 Inches Transported By: LMC
Air Content: 4.2% Source/Sampled At: Truck / Center
Mix Code: 1701 Plant: 955E
Date Received: 11/13/2015 Truck/Ticket No: 1425 / 64394318
Curing Method: Standard
Time Sampled: 4:25 pm
Time Batched: 3:01 pm
Temp.: Ambient: 67°F Mix: 88°F
Unit Weight: 145 8 #/cu ft
Quantity Represented: 9.5 cu. yds. at 9 5 cu, yds placed of a 28.5 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Orig: City of Coppell (Coppell, TX) Attn: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, SET, CME Department Manager
1"1115 REPORT APPL IES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
I FIE. QUALITIES OF APPARENTLY IDENTICAL. OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
nLLIF9NCE
3E0TEcmr 11CAL
4 GROUP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812 Date Sampled: 11/13/2015
Report Date: 12/15/2015 Previously Reported: 11/20/2015 Sampled By: Smith, Vernon
Project: Freeport Parkway North By Order Of: Walter
Location: Inlet at Station 1+25.74 and Manhole at Station 0+00.00, Order Number: 1770
Sampled-, North Freeport Parkway
Number of
Client: City of Coppell Specimens: 4
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 197596
Material: Concrete Test Method: See Below
TEST RESULTS Report No: 197596
Page 1 of 1
Spec
Nbr
A
B
C
D
Type 1
Specification
Strength: 4,200 psi @ 28 days
Slump: 3-5
Air Content: 3-6
Date Received:
11/14/2015
Curing Method:
Maximum
Time Sampled:
1:25 pm
Compressive
Average
Temp.: Ambient:
Age Tested
Diameter
Area
Load
Cure
Strength
Strength
Tested
(date : days)
(in)
(inZ)
(lbs)
Break Type
Loc
(PSI)
(PSI)
By
11/20/15: 7
6.00
28.27
120,700
Type 3
Lab
4,270
4,270
JR
12/11/15: 28
6.00
28.27
164,300
Type 3
Lab
5,810
JR
12/11/15: 28
6.00
28.27
168,920
Type 3
Lab
5,970
5,890
JR
Type 1
Specification
Strength: 4,200 psi @ 28 days
Slump: 3-5
Air Content: 3-6
Date Received:
11/14/2015
Curing Method:
Standard
Time Sampled:
1:25 pm
'Time Batched:
11:57 am
Temp.: Ambient:
69°F Mix: 74°F
Comments
HOLD (see remarks) -
),1.. li, I �' .4.... I � 15';,,.II �``.....1 �^V I •� ill
! Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 3.0 Inches Transported By: Redi-Mix
Air Content: 3.5% Source/Sampled At: Truck I Center
Mix Code: 1 OM21524 Plant: 136
Truck/Ticket No: 1347 / 25190509
Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 10 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Orig, City of Coppell (Coppell, FX) Altn: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
fff
Perry C. Kakara, SET, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENn.Y IDENT ICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENTAN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE. EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.