ST0502B- LR160104 (2)ALLIfU'ICE GGEOTKHf'IlCRL GROU Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C15-0812 Report Date: 01/04/2016 Previously Reported: 12/15/2015 Project: Freeport Parkway North Location: Misc. Concrete Client: REPORT: City of Coppell REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST TEST RESULTS Set: 1 of 2 Material: Concrete Location: Wall B retaining wall, Station 0+00 to 0+69.34 Maximum Compressive Spec Age Tested Diameter Area Load Cure Strength Nbr (date : days) (in) (int) (lbs) Break Type Loc (PSI) Date Sampled: 12/04/2015 Sampled By: Avila, Eli By Order Of: Walter Order Number: 1770 LAB NO: 198708 Test Method: See Below Report No: 198708 Page 1 of 2 Number of Specimens: 4 Average Strength Tested (PSI) By Comments A 12/11/15: 7 6.00 28.27 126,785 Type 3 Lab 4,480 4,480 JR B 01/01/16: 28 6.00 28.27 151,610 Type 3 Lab 5,360 JR C 01/01/16: 28 6.00 28.27 150,125 Type 3 Lab 5,310 5,340 JR D HOLD (see remarks) - Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification CONFORMS Strength: 3,600 psi @ 28 days Slump: 3-5 Slump: 4.0 Inches Transported By: LMC Air Content: 3-6 Air Content: 2.5% Source/Sampled At: Truck / Center Mix Code: 1701 Plant: 956 Date Received: 12/05/2015 TruckMcket No: 9102 / 63097101 Curing Method: Standard Time Sampled: 11:34 am Time Batched: 10:34 am Tbmp.: Ambient: 52°F Mix: 64°F Unit Weight: 152.4 #/cu ft Quantity Represented: 9.5 cu. yds. at 9.5 cu. yds. placed of a 17.0 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C1064 and C138, Compressive strength test per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Orig: City of Coppell (Coppell, TX) Attn: Mr. Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group - Perry C. Kakara, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION RLLlfil'KE GGEOTECFiIYICRL GROUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C15-0812 Report Date: 01/04/2016 Previously Reported: 12/15/2015 Project: Freeport Parkway North Location: Misc. Concrete Client: REPORT: City of Coppell REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST TEST RESULTS Set: 2 of 2 Material: Concrete Location: Traffic signal Pier P-4 at Station 0+78 Date Sampled: 12/04/2015 Sampled By: Avila, Eli By Order Of: Walter Order Number: 1770 LAB NO: 198708 Test Method: See Below Report No: 198708 Page 2 of 2 Number of Specimens: 4 Curing Method: Standard Time Sampled: 1:10 pm Time Batched: 12:18 pm Temp.: Ambient: 60°F Mix: 68°F Quantity Represented: 5 cu. yds. at 5 cu, yds. placed of a 5 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C1064 and C138, Compressive strength test per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Orig: City of Coppell (Coppell, TX) Attn: Mr. Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C, Kakara, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (int) (Ibs) Break Type Loc (PSI) (PSI) By Comments A 12/11/15: 7 6.00 28.27 146,880 Type 3 Lab 5,190 5,190 JR B 01/01/16: 28 6.00 28.27 174,195 Type 3 Lab 6,160 JR C 01/01/16: 28 6.00 28.27 172,810 Type 3 Lab 6,110 6,140 JR D HOLD (see remarks) - 11x1 Pq1 iMIJ 9l FF 17 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification CONFORMS Strength: 4,000 psi @ 28 days Slump: 3-5 Slump: 3.0 Inches Transported By: LMC Air Content: 0.5-2.5 Air Content: 2.0% Source/Sampled At: Truck/ Center Mix Code: 1701 Plant: 956 Date Received: 12/05/2015 Truck/Ticket No: 1407 / 63097103 Curing Method: Standard Time Sampled: 1:10 pm Time Batched: 12:18 pm Temp.: Ambient: 60°F Mix: 68°F Quantity Represented: 5 cu. yds. at 5 cu, yds. placed of a 5 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C1064 and C138, Compressive strength test per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Orig: City of Coppell (Coppell, TX) Attn: Mr. Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C, Kakara, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION