Loading...
ST0502B- LR160104 (3)19LLiAnce GGEOTECHfIICRL GROUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C15-0812 Date Sampled: 12/07/2015 Report Date: 01/04/2016 Previously Reported: 12/15/2015 Sampled By: Selman, Mario Project: Freeport Parkway North By Order Of: Walter Location: Freeport Parkway and Sandy Lake, Sampled; Station 3+59.46 Order Number: 1770 Freeport Parkway and Sandy Lake inlet box Client: REPORT: Material: City of Coppell REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST Concrete TEST RESULTS Number of Specimens: 4 LAB NO: 198851 Test Method: See Below Report No: 198851 Page 1 of 1 Average Strength Tested (PSI) By Comments 4,530 JR JR 5,660 JR F -IF FU M F1 Maximum 1 i Type 1 Compressive Spec Age Tested Diameter Area Load Cure Strength Nbr (date : days) (in) (int) (Ibs) Break Type Loc (PSI) A 12/14/15 :7 6.00 28.27 128,150 Type 3 Lab 4,530 B 01/04/16: 28 6.00 28.27 160,770 Type 3 Lab 5,690 C 01/04/16: 28 6.00 28.27 159,100 Type 3 Lab 5,630 D Number of Specimens: 4 LAB NO: 198851 Test Method: See Below Report No: 198851 Page 1 of 1 Average Strength Tested (PSI) By Comments 4,530 JR JR 5,660 JR F -IF FU M F1 1 1 i Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification CONFORMS HOLD (see remarks) - Strength: 4,200 psi @ 28 days Slump: 3-5 Slump: 4.5 Inches Transported By: Redi-Mix Air Content: 3-6 Air Content: 4.6% Source/Sampled At: Truck / Center Mix Code: 1 OM21524 Plant: P259 Date Received: 12/08/2015 Truck/Ticket No: 1235 / 25201 905 Curing Method: Standard Time Sampled: 1:30 pm 'Time Batched: 12:46 pm Temp.: Ambient: Mix: 68°F Unit Weight: 146.4 #/cu ft Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 10 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Orig: City of Coppell (Coppell, TX) Attn: Mr, Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENTAN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.