ST0502B- LR160115 (2)AtLiRnce GGEOTECNf11CFlL _ GROUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C15-0812 Report Date: 01/15/2016 Previously Reported: 12/28/2015 Project: Freeport Parkway North Location: Freeport Parkway and West Sandy Lake, Sampled-, Station 11 +87.10 headwall Client REPORT: Material: Date Sampled: 12/17/2015 Sampled By: Selman, Mario By Order Of: Walter Order Number: 1770 Number of City of Coppell Specimens: 4 REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 199643 Concrete Test Method: See Below TEST RESULTS Report No: 199643 Page 1 of 1 Date Received: 12/18/2015 Truck/Tic e o. Curing Method: Standard Time Sampled: 3:45 pm Time Batched: Temp.: Ambient: 66°F Mix: 70°F Unit Weight: 144.3 #/cu ft Quantity Represented: 9 5 cu. yds at 9.5 cu. yds. placed of a 28.5 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Orig: City of Coppell (Coppell, TX) Attn: Mr Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C, Kakara, SET, CME Department Manager HIS REPORI APPLIES ONLY TO INE STANDARDS OR PROCEDURES INDICATED AND TO'THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THG QUALITIES OF APPARENTLY IDENTICAL OR SIMII AR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENTAN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOI TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (int) (Ibs) Break Type Loc (PSI) (PSI) By Comments A 12/24/15 : 7 600 28.27 116,795 Type 3 Lab 4,130 4,130 JR B 01/14/16: 28 6.00 28.27 162,250 Type 3 Lab 5,740 JR C 01/14/16: 28 600 28.27 160,170 Type 3 Lab 5.660 5,700 JR HOLD (see remarks) D I1IFr Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: Slump: 3-5 Slump: 3.5 Inches Transported By: LMC Air Content: 3-6 Air Content: 4.2% Source/Sampled At: Truck / Center Mix Code: 1701 Plant: 956 k t N 5004 / 63097399 Date Received: 12/18/2015 Truck/Tic e o. Curing Method: Standard Time Sampled: 3:45 pm Time Batched: Temp.: Ambient: 66°F Mix: 70°F Unit Weight: 144.3 #/cu ft Quantity Represented: 9 5 cu. yds at 9.5 cu. yds. placed of a 28.5 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Orig: City of Coppell (Coppell, TX) Attn: Mr Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C, Kakara, SET, CME Department Manager HIS REPORI APPLIES ONLY TO INE STANDARDS OR PROCEDURES INDICATED AND TO'THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THG QUALITIES OF APPARENTLY IDENTICAL OR SIMII AR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENTAN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOI TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.