Loading...
ST0502B- LR160202�J ALLlfil'ICE -�j GEOTECI'1'11CPIL GROUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C15-0812 Report Date: 02/02/2016 Project: Freeport Parkway North Location: Freepost crossover Client: City of Coppell Date Sampled: 01/28/2016 Sampled By: Perez, Julio By Order Of: Walter Order Number: 1770 REPORT. Nuclear Field Density Test LAB NO: 202486 Test Method: See Below TEST RESULTS Report No: 202486 Page 1 of 1 Optimum Maximum Proctor Moisture Dry Density Proctor No Date (%) (pcf) Color / Description 199727-2 12/18/2015 13.9 117.7 Cement Treated Brown Sandy Clay Specification Moisture Band Specification No. Compaction, % Minimum Maximum 1 95 -2.0 5.0 Location: Wet Moisture Dry Percent Test Lift # / Density Content Density Proctor Spec. Moisture Proctor Pass No. Depth Location (pcf) % (pcf) Number No. Deviation Density Fail 1 Final Station 26+00 131.2 14.7 114.4 199727-2 1 +0.8 97.2 Pass 2 Final Station 23+00 131.6 14.2 115.2 199727-2 I +0.3 97.9 Pass 3 Final Station 19+00 129.7 15.3 112.5 199727-2 1 +1.4 95.6 Pass 4 Final Station 15+50 129.6 14.1 113.6 199727-2 1 +0.2 96.5 Pass 5 Final Station 9+50 133.3 15.0 115.9 199727-2 1 +1.1 98.5 Pass 6 Final Station 5+00 131.2 14.4 114.7 199727-2 1 +0.5 97.5 Pass Gauge No.: 5669 Daily Standard Counts: 01/28/2016 DS: 3093 MS: 452 Test Methods: ASTM D6938-10 CONFORMS Orig: City of Coppell (Coppell, TX) Attn: Mr. Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group 8 -4 -d -44-L-- Perry C. Kak ra, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. ALLIAnCE GRWP Acct ID: 1770 Report Date: 02/02/2016 Project: Freeport Parkway North Location: Reinforcing Steel Inspection Client: City of Coppell REPORT. Reinforcing Steel Inspection Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 File No: C15-0812 Date Sampled: 01/28/2016 Sampled By: Julio Perez By Order Of: Walter Order Number: 1770 LAB NO: 202486-1 TEST RESULTS Report No: 202486-1 Page 1 of 1 We visually inspected the reinforcing steel on paving. Our inspection included verifying the proper size of the reinforcing steel including diameter, length, bends and anchorage, and the grade and the location of the bars including spacing and cover. We also verified proper splicing, checked stability of tying, and checked the reinforcing steel for excessive rust deposits. Paving: On crossover and turn lane on Freeport Parkway • Drawing Date: 1/23/2015 Addendum No: 3 • Details Referenced: Detail A, Rebar #4@18" OC Orig: City of Coppell (Coppell, TX) Attn: Mr. Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. ALLIANCE JGGGEOTECNfIICHL GROUP Acct ID: 1770 Report Date: 02/02/2016 Project: Freeport Parkway North Location: Inlet Tops Client: City of Coppell REPORT: Reinforcing Steel Inspection Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 File No: C15-0812 Date Sampled: 01/27/2016 Sampled By: David Rooney By Order Of: Walter Order Number: 1770 LAB NO: 202319-1 TEST RESULTS Report No: 202319-1 Page 1 of 1 We visually inspected the reinforcing steel for the areas listed below. Our inspection included verifying the proper size of the reinforcing steel including diameter, length, bends and anchorage, and the grade and the location of the bars including spacing and cover. We also verified proper splicing, checked stability of tying, and checked the reinforcing steel for excessive rust deposits. • Inlet Tops Drawing Date: 1/22/2015 Details Referenced: #4 rebar at 7.5" OC, pg 6020-1 Remarks: Rebar is within spec, Sta 3+59 and 1+28 Orig: City of Coppell (Coppell, TX) Attn: Mr. Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Ile— Perry C, Kakara, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION