ST0301C- LR160204:CHNICAL. ENGINEERING
ENVIRONMENTAL CONSULTING GEE Consultants, Inc.
T* CONSTRUCTION MATERIALS TESTING
10046 Monroe Drive • Dallas, Texas 75229 (214) 352-5433
Fax (214) 352-6972
REPORT OF CONCRETE MIX OBSERVATION
Measured
Slump (in.)
Report Date:
February 4, 2016 Date Concrete Placed: January 28, 2016
Standard 6"x12" Cylinders
Client:
City of Coppell
Cylinder Cross-sectional Area: 28.27 Square Inches
Project:
Bethel & Coppell Road
2/4/16
Concrete Report No.: 64
Contractor:
Axis Contracting
BCR 292
Project No.: 215-140
Concrete Supplier and Plant:
TXI Operations. LP/141
Location of Placement:
Sidewalk at N. Bound form Bethel Rd.
to 572
MATERIALS
Source / SSD Batch Wts.
OBSERVATION DATA
BCR 293
Description (Lbs/CuYd)
28
2/25/16
Mix Number:
8272
Time Sample Batched:
11:00 AM
Cement:
5 Sacks
Time Sampled:
11:50 AM
Fly Ash:
Sample Location:
Sidewalk at 20' S. of 615, N.
Cylinders Made By: HP
ASTM C-31, C-39, C-143
(Unless Noted Otherwise)
Bound
Coarse Aggregate:
Truck / Ticket No:
0000/64442
Intermediate Aggregate:
Temperature:
Fine Aggregate:
Ambient Range:
59 OF
Admixtures:
Concrete Range:
63 OF
Slump Range (inches):
4.0
1
Weather Conditions:
Clear
2
Time Started:
10:15 AM
Time Completed:
3:45 PM
Added Water:
0 Gal
0
Sample Air Content (/o):
4.5
Total Cubic Yards Placed:
20.0
Required Strength (Lbs./sq.in.):
3,000
Specimen
Number
Measured
Slump (in.)
Age
(Days)
Date
Tested
Total Load
(Lbs.)
Compressive Strength
(Lbs./Sq.ln.)
Remarks
BCR 291
7
2/4/16
108,500
3,840
BCR 292
28
2/25/16
4.0
BCR 293
28
2/25/16
BCR 294
H
H
Test Methods Utilized
Fracture Regular
Cylinders Made By: HP
ASTM C-31, C-39, C-143
(Unless Noted Otherwise)
Remarks and/or Distribution:
cc: Mr. Rick Odell - City of Coppell via E-mail: Roden c ,coppelltx.gov
Mr. Michelle Matunas - City of Coppell via Email: mmatunas(&coppelltx.gov
Mr. George Marshall - City of Coppell via Email: gmarshallAcoppelltx.gov
Mr. Robert Caudill - Tiseo Paving via Email: rcaudill(ia tiseorlaving.com
2
GEE Consultants, Inc. TBPE Firm: F-3212 Reviewed by: Q
All letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced without the full approval of GEE Consultants, Inc. The use of our name must receive
our prior written approval. Our letters and reports apply only to the sample tested and/or observed and are not necessarily indicative of the quantities of apparently identical or similar products.