3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Report Date: 02/15/2016 Previously Reported: 01/25/2016
Project: Freeport Parkway North
Location: Paving
Client. City of Coppell _
REPORT REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Set: 1 of 18
Location: Station 29+50
Spec;
Age Tested
Nbr
(date : days)
A
01/18/16: 3
B
01/22/16:7
C
02/12/16:28
D
02/12/16:28
E
09/04/40:8,999
TEST RESULTS
Material: Concrete
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
Maximum
Cure
Strength
Diameter
Area Load
Lab
3,750
(in)
(int) (Ibs)
Break
Type
6.00
28.27 105,910
Type 3
6.00
28.27 114,938
Type 3
6.00
28.27 147,920
Type 2
6.00
28,27 150,070
Type 2
6 00
28.27
t 11
I\
Type 1 Type
2
Type
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
Date Sampled: 01/15/2016
Sampled By: Reyes, Jason
By Order Of: Walter
Order Number: 1770
LAB NO: 201195
Test Method: See Below
Report No: 201195
Page 1 of 18
Number of Specimens: 5
Average
Compressive
Cure
Strength
Loc
(PSI)
Lab
3,750
Lab
4,070
Lab
5,230
Lab
5,310
Date Sampled: 01/15/2016
Sampled By: Reyes, Jason
By Order Of: Walter
Order Number: 1770
LAB NO: 201195
Test Method: See Below
Report No: 201195
Page 1 of 18
Number of Specimens: 5
Average
Strength
Tested
(PSI)
By Comments
3,750
JR
4,070
MM
JR
5,270
Lab
3 Type 4 Type 5 Type 6
CONFORMS
Slump: 1.5 Inches Transported By: Tiseo
Air Content: 7.0% Source/Sampled At: Truck / Center
Mix Code: 2605M Plant: On -Site
Date Received: 01/16/2016 Truck/Ticket No: N/A124279
Curing Method: Standard
Time Sampled: 7:20 am
Time Batched: 7:02 am
Temp : Ambient: 46'F Mix: 59'F
Unit Weight: 140.6 #/cu ft
Quantity Represented: 10 cu. yds. at 20 cu. yds. placed of a 780 cu, yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617
Orig: City of Coppell (Coppell, FX) Attn: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, SET, CME Department Manager
I I HIS REPORT ADPL IES ONLY TO THF. STANDARDS OR PROCEDURES IND[CN ED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OI
THI= OJAI IT IFS OF APPARFNTI Y IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO T HEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOT[ D. I HEST REPORI S ARE FOR TI IF EXCLUSIVE USE OF T HF ADDRESSED CI IFN I AND ARE. NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION
AtLiAnce
GGEOTKHnlCFlL
GROUP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Report Date: 02/15/2016 Previously Reported: 01/25/2016
Project. Freeport Parkway North
Location: Paving
Client
REPORT:
City of Coppell
REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Set: 2 of 18
Location: Station 28+50
Spec
Age Tested
Diameter
Area
Nbr
(date : days)
(in)
(in')
A
01/18/16: 3
600
28.27
B
01/22/16:7
6.00
28.27
C
02/12/16:28
6.00
28.27
D
02/12/16:28
6.00
2827
E
Type 3
Lab
4,380
TEST RESULTS
Material: Concrete
Date Sampled: 01/15/2016
Sampled By: Reyes, Jason
By Order Of: Walter
Order Number: 1770
LAB NO: 201195
Test Method: See Below
Report No: 201195
Page 2 of 18
Number of Specimens: 5
Maximum
Compressive
Average
Load
Cure
Strength
Strength
Tested
(lbs)
Break Type
Loc
(PSI)
(PSI)
By
107,765
Type 3
Lab
3,810
3,810
JR
123,840
Type 3
Lab
4,380
4,380
MM
165,045
Type 3
Lab
5,840
JR
160,920
Type 5
Lab
5,690
5,760
JR
Type 1
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
Comments
HOLD (see remarks) -
It:'I�t,I
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 2.0 Inches Transported By: Tiseo
Air Content: 4.6% Source/Sampled At: Truck ! Center
Mix Code: 2605M Plant: On -Site
Date Received: 01/16/2016 Truck/Ticket No: N/A 124291
Curing Method: Standard
Time Sampled: 8:05 am
Time Batched: 7:44 am
Ternp,: Ambient: 46'F Mix: 62°F
Unit Weight: 145.7 #/cu ft
Quantity Represented: 6 cu. yds. at 132 cu, yds placed of a 780 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTNI C31, C172, C143,
C1064 and C138 Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Orig Cily of Copp oII (Cop pelI, TX) Attn: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, SET, CME Department Manager
1141S REPORT APPL IES ONLY TO IHE SIANOARDS OR PROCEDURES INDICAI ED AND FO THE SAMPLE(S) I ES TED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE Of
I E OJAI I I IES OF APPARI NT I Y IDEM ICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NO] 17) I HI.SE REPORTS ARF FOR I IIF. LXCI USIVE USE OFTl IF ADDRESSED CLIEN I AND ARE NOI TO BE REPRODUCED WITHOUT WRITTEN PERMISSION
AtLiAnce
4DGEOTECFit11CfiL
GFiOUP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Report Date: 02/15/2016 Previously Reported: 01/25/2016
Project: Freeport Parkway North
Location: Paving
_Client: City of Coppell
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Set: 3 of 18
Location: Station 27+78.29
Spec
Age Tested
Diameter
Area
Nbr
(date : days)
(in)
(in')
A
01/18/16:3
6.00
28.27
B
01/22/16:7
6.00
28.27
C
02/12/16:28
6.00
28.27
D
02/12/16:28
6.00
28.27
E
Type 3
Lab
4,920
TEST RESULTS
Material: Concrete
Date Sampled: 01/15/2016
Sampled By: Reyes, Jason
By Order Of: Walter
Order Number: 1770
LAB NO: 201195
Test Method: See Below
Report No: 201195
Page 3 of 18
Number of Specimens: 5
Maximum
Compressive
Average
Load
Cure
Strength
Strength
Tested
(Ibs)
Break Type
Loc
(PSI)
(PSI)
By Comments
114,050
Type 3
Lab
4,030
4,030
JR
139,150
Type 3
Lab
4,920
4,920
MM
173,440
Type 4
Lab
6,130
JR
177,910
Type 4
Lab
6,290
6,210
JR
HOLD (see remarks) -
I y+.
Type 1
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 1.5 Inches Transported By: Tiseo
Air Content: 5.0% Source/Sampled At: Truck / Center
Mix Code: 2605M Plant: On -Site:
Date Received: 01/16/2016 Truck/Ticket No: N/A/ 24301
Curing Method: Standard
Time Sampled: 8:30 am
Time Batched: 8:11 am
Temp.: Ambient: 47°F Mix: 61°F
Unit Weight: 145 2 #/cu ft
Quantity Represented: 10 cu yds. at 230 cu yds, placed of a 780 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Orig: City of Coppell (Coppell, TX) Attn: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
111
Perry C. Kakara, SET, CME Department Manager
I 111 REPORT APPI IFS ONI Y 10 11 IL STANDARDS OR PROCEDURES INDICAT FD AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
T HE QUALIT IES OF APPARENTLY IDENT ICA[ OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTFII. I HUSF REPORTS ARE FOR THE F_XCLUSIVE USF OF THF_ ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
RLLIPInCE
GGEOTECHnICRL
GROUP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Report Date: 02/15/2016 Previously Reported: 01/25/2016
Project: Freeport Parkway North
Location: Paving
Client: City of Coppell
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Set: 4 of 18
Location: Station 26+89
Spec
Age Tested
Diameter
Area
Nbr
(date : days)
(in)
(in')
A
01/18/16:3
6.00
28-27
B
01/22/16:7
6.00
28.27
C
02/12/16:28
6.00
28.27
D
02/12/16:28
6.00
28.27
E
Lab
5,060
5,060
TEST RESULTS
Material: Concrete
Date Sampled: 01/15/2016
Sampled By: Reyes, Jason
By Order Of: Walter
Order Number: 1770
LAB NO: 201195
Test Method: See Below
Report No: 201195
Page 4 of 18
Number of Specimens: 5
Maximum
Compressive
Average
Load
Cure
Strength
Strength Tested
(Ibs)
Break Type
Loc
(PSI)
(PSI)
By Comments
122,400
Type 3
Lab
4,330
4,330
JR
143,095
Type 3
Lab
5,060
5,060
MM
179,260
Type 3
Lab
6,340
JR
176,420
Type 5
Lab
6,240
6,290
JR
. lyl
Type 1
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
HOLD (see remarks) -
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 1.5 Inches Transported By: Tiseo
Air Content: 5.1 % Source/Sampled At: Truck / Center
Mix Code: 2605M Plant: On -Site
Date Received: 01/16/2016 Truck/Ticket No: N/A/ 24311
Curing Method: Standard
Time Sampled: 8:55 am
rime Batched: 8:36 am
Temp.: Ambient: 49°F Mix: 61°F
Unit Weight: 145.6 #/cu ft
Quantity Represented: 10 cu. yds, at 330 cu. yds placed of a 780 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138 Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Ong Cily of Coppoll (Coppell, 1 X) Alln Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, SET, CME Department Manager
1111S DEPORT APPI IPS ONI Y TO FI -IF. STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE= OF
TFII_ OJAI.IT IFS OP APPAR[ N FI Y IDPNTICAI OR SIMIIAR PRODUCTS OR PROCEOURFS. NOR DOIHEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTI A 1 I II:SE REPORTS ARL FOR THE FXCI USIVE USE OF THE ADDRESSED CI IFN I AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
MuAnce
(�GG GEOTECHnICRL
GROUP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Report Date: 02/15/2016 Previously Reported: 01/25/2016
Project: Freeport Parkway North
Location: Paving
Client:
REPORT:
City of Coppell
REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Set: 5 of 18
Location: Station 26+00
Spec=
Nbr
A
B
C
D
E
TEST RESULTS
Material: Concrete
Date Sampled: 01/15/2016
Sampled By: Reyes, Jason
By Order Of: Walter
Order Number: 1770
LAB NO: 201195
Test Method: See Below
Report No: 201195
Page 5 of 18
Number of Specimens: 5
Type 1
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
Comments
HOLD (see remarks)
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 1.5 Inches Transported By: Tiseo
Air Content: 48% Source/Sampled At: Truck / Center
Mix Code: 2605M Plant: On -Site:
Date Received: 01/16/2016 Truck/Ticket III N/A/ 24322
Curing Method: Standard
Time Sampled: 9:35 am
Time Batched: 9:07 am
Temp.: Ambient: 49°F Mix: 62°F
Unit Weight: 145,8 #/cu ft
Quantity Represented: 10 cu. yds. at 440 cu. yds. placed of a 780 cu- yd_ total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138 Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Oriq Clly of Coppell (Coppell, TX) Attn: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
f _
Perry C. Kakara, SET, CME Department Manager
1 HIS REPORT APPLIES ONI Y 10 FFIF STANDARDS OR PROCEDURES INDICATED AND TO TI IE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICArIVE OF
THE QJAI.ITIF--S OF APPARI Nil Y IDFNTICAI OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED, TI-IESE REPORTS ARE FOR 11 It- C XCI USIVF USE OF 11 IF ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
Maximum
Compressive
Average
Age Tested
Diameter
Area
Load
Cure
Strength
Strength
Tested
(date : days)
(in)
(in')
(lbs)
Break Type
Loc
(PSI)
(PSI)
By
01/18/16 .3
6.00
28.27
127,150
Type 3
Lab
4,500
4,500
JR
01/22/16: 7
6.00
28.27
148,100
Type 3
Lab
5,240
5,240
MM
02/12/16: 28
6.00
28.27
179,325
Type 4
Lab
6,340
JR
02/12/16: 28
6.00
2827
178,995
Type 4
Lab
6,330
6,340
JR
Type 1
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
Comments
HOLD (see remarks)
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 1.5 Inches Transported By: Tiseo
Air Content: 48% Source/Sampled At: Truck / Center
Mix Code: 2605M Plant: On -Site:
Date Received: 01/16/2016 Truck/Ticket III N/A/ 24322
Curing Method: Standard
Time Sampled: 9:35 am
Time Batched: 9:07 am
Temp.: Ambient: 49°F Mix: 62°F
Unit Weight: 145,8 #/cu ft
Quantity Represented: 10 cu. yds. at 440 cu. yds. placed of a 780 cu- yd_ total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138 Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Oriq Clly of Coppell (Coppell, TX) Attn: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
f _
Perry C. Kakara, SET, CME Department Manager
1 HIS REPORT APPLIES ONI Y 10 FFIF STANDARDS OR PROCEDURES INDICATED AND TO TI IE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICArIVE OF
THE QJAI.ITIF--S OF APPARI Nil Y IDFNTICAI OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED, TI-IESE REPORTS ARE FOR 11 It- C XCI USIVF USE OF 11 IF ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
nLUnriCE
$ , OEOTECHrilUIL
Chow'
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 7524.7
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Report Date: 02/15/2016 Previously Reported: 01/25/2016
Project: Freeport Parkway North
Location: Paving
Client: City of Coppell
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Set: 6 of 18
Location: Station 25+50
Spec
Age Tested
Diameter
Area
Nbr
(date : days)
(in)
(in')
A
01118/16:3
6.00
28.27
B
01/22/16:7
6.00
28.27
C
02/12/16:28
6.00
28.27
D
02/12/16: 28
600
28.27
E
Type 3
Lab
5,610
TEST RESULTS
Material: Concrete
Date Sampled: 01/15/2016
Sampled By: Reyes, Jason
By Order Of: Walter
Order Number: 1770
LAB NO: 201195
Test Method: See Below
Report No: 201195
Page 6of18
Number of Specimens: 5
Maximum
Compressive
Average
Load
Cure
Strength
Strength
Tested
(lbs)
Break Type
Loc
(PSI)
(PSI)
By
139,175
Type 3
Lab
4,920
4,920
JR
158,705
Type 3
Lab
5,610
5,610
MM
184,605
Type 5
Lab
6,530
JR
186,720
Type 5
Lab
6,600
6,570
JR
Type 1
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 1.0 Inches
Air Content: 3.9%
Mix Code: 2605M
Comments
HOLD (see remarks) -
Transported By: Tiseo
Source/Sampled At: Truck / Center
Plant: On -Site
Crate Received: 01I16I2016 Truck/Ticket No: N/A / 24329
Curing Method: Standard
Time Sampled: 9:45 am
Time Batched: 9:24 am
Temp.: Ambient: 51°F Mix: 63°F
Unit Weight: 147.9 #/cu ft
Quantity Represented: 10 cu. yds. at 510 cu. yds. placed of a 780 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617
Orig: City of Coppoll (Coppell, TX) Attn: Mr Rick O'Dell (1 -CC Copy)
Respectfully Submitted,
Alliance Geotechnical Group
r
Perry C. Kakara, SET, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THF QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. l HESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
AuiAnce
u-EorernrncAL
GR UP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Report Date: 02/15/2016 Previously Reported: 01/25/2016
Project: Freeport Parkway North
Location: Paving
Client
REPORT
City of Coppell
REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Set: 7 of 18
Location: Station 24+98.11
Spec
Age Tested
Diameter
Nbr
(date : days)
(in)
A
01/18/16:3
6.00
B
01/22/16: 7
600
C
02/12/16:28
6.00
D
02/12/16:28
6.00
E
(PSI)
By Comments
TEST RESULTS
Material: Concrete
Date Sampled: 01/15/2016
Sampled By: Reyes, Jason
By Order Of: Walter
Order Number: 1770
LAB NO: 201195
Test Method: See Below
Report No: 201195
Page 7 of 18
Number of Specimens: 5
Type 1
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 1.0 Inches
Air Content: 4.0%
Mix Code: 2605M
HOLD (see remarks) -
Transported By: Tiseo
Source/Sampled At: Truck / Center
Plant: On -Site
Crate Received: 01/16/2016 Truck/Ticket No: N/A/ 24,540
Curing Method: Standard
Time Sampled: 10:30 am
Time Batched: 9:55 am
Temp.: Ambient: 50°F Mix: 63°F
Unit Weight: 145.6 #/cu ft
Quantity Represented: 10 cu. yds. at 620 cu yds placed of a 780 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138 Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617
Orifi: City of Coppoll (Coppell, FX) Attn: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, SET, CME Department Manager
1 HIS REPORTAPPI IES ONI Y TO I HE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE Of-
HIT
f-f fIG O'JAI ITIFS OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTI.1). 11IFSF REPORTS ARE I -OR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION
Maximum
Compressive
Average
Area
Load
Cure
Strength
Strength
Tested
(int)
(lbs)
Break Type
Loc
(PSI)
(PSI)
By Comments
28.27
112,095
Type 3
Lab
3,960
3,960
JR
28.27
154,995
Type 3
Lab
5,480
5,480
MM
2827
187,525
Type 3
Lab
6,630
JR
28.27
189,040
Type 2
Lab
6,690
6,660
JR
Type 1
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 1.0 Inches
Air Content: 4.0%
Mix Code: 2605M
HOLD (see remarks) -
Transported By: Tiseo
Source/Sampled At: Truck / Center
Plant: On -Site
Crate Received: 01/16/2016 Truck/Ticket No: N/A/ 24,540
Curing Method: Standard
Time Sampled: 10:30 am
Time Batched: 9:55 am
Temp.: Ambient: 50°F Mix: 63°F
Unit Weight: 145.6 #/cu ft
Quantity Represented: 10 cu. yds. at 620 cu yds placed of a 780 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138 Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617
Orifi: City of Coppoll (Coppell, FX) Attn: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, SET, CME Department Manager
1 HIS REPORTAPPI IES ONI Y TO I HE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE Of-
HIT
f-f fIG O'JAI ITIFS OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTI.1). 11IFSF REPORTS ARE I -OR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION
ALLiAnce
GGEOTECF1h1KRL
GROUP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No:
C15-0812
Date Sampled: 01/15/2016
Report Date: 02/15/2016 Previously Reported:
01/25/2016
Sampled By: Reyes, Jason
Project: Freeport Parkway North
By Order Of: Walter
Location: Paving
Order Number: 1770
Client: City of Coppell
----
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
LAB NO: 201195
Test Method See Below
TEST RESULTS
Report No: 201195
Page 8 of 18
Set: 8 of 18 Material: Concrete
Number of Specimens: 5
Location: Station 24+00
Maximum
Compressive
Average
Spec: Age Tested Diameter Area Load
Cure Strength
Strength Tested
Nbr (date : days) (in) (in') (lbs)
Break Type Loc (PSI)
(PSI) By Comments
A 01/18/16: 3 6.00 28.27 135,575
Type 3 Lab 4,790
4,790 JR
B 01/22/16: 7 6.00 28.27 152,975
Type 3 Lab 5,410
5,410 MM
C 02/12/16: 28 6.00 28.27 189,085
Type 6 Lab 6,690
JR
D 02/12/16: 28 6.00 28.27 190,295
Type 5 Lab 6,730
6,710 JR
HOLD (see remarks) -
E
Type 1 Type 2 Type 3 Type 4 Type 5
Type 6
Specification
CONFORMS
Strength: 3,600 psi @ 28 days
Slump: 1-3
Slump: 1.0 Inches
Transported By: Tiseo
Air Content: 3-6
Air Content: 3.7%
Source/Sampled At: Truck / Center
Mix Code: 2605M
Plant: On -Site
ITlt N N/A / 24350
Date Received: 01/16/2016 Truck cke V.
Curing Method: Standard
Time Sampled: 11:20 am
Time Batched: 10:53 am
Temp.: Ambient: 52°F Mix: 66'F
Unit Weight: 148 #/cu ft
Quantity Represented: 10 cu. yds at 720 cu. yds. placed of a 780 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Orig: City of Coppell (Coppell, TX) Attn: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
f
Perry C. Kakara, SET, CME Department Manager
'THIS R.EPORTAPPt IES ONLY TO 1"HE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE= OF
THE QJALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. l HESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
RLLIAIYCE
GGEOTECH'IICRL
GROUP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Report Date: 02/15/2016 Previously Reported: 01/25/2016
Project: Freeport Parkway North
Location: Paving
Client: City of Coppell
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
TEST RESULTS
Set: 9 of 18 Material: Concrete
Location: Station 23+35
Spec:
Age Tested
Diameter
Area
Nbr
(date : days)
(in)
(in')
A
01/18/16: 3
6.00
28 27
B
01/22/16: 7
600
28.27
C
02/12/16:28
6.00
28.27
D
02/12/16:28
6.00
28.27
E
Type 3
Lab
5,680
Date Sampled: 01/15/2016
Sampled By: Reyes, Jason
By Order Of: Walter
Order Number: 1770
LAB NO: 201195
Test Method: See Below
Report No: 201195
Page 9of18
Number of Specimens: 5
Maximum
Compressive
Average
Load
Cure
Strength
Strength
Tested
(lbs)
Break Type
Loc
(PSI)
(PSI)
By
127,585
Type 3
Lab
4,510
4,510
JR
160,575
Type 3
Lab
5,680
5,680
MM
160,900
Type 3
Lab
5,690
JR
161,240
Type 6
Lab
5,700
5,700
JR
Type 1
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
Comments
HOLD (see remarks) -
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 1.5 Inches Transported By: Tiseo
Air Content: 3.9% Source/Sampled At: Truck I Center
Mix Code: 2605M Plant: On -Site
Date Received: 01/16/2016 Truck/Ticket No: N/A/ 24361
Curing Method: Standard
Time Sampled: 11:55 am
Time Batched: 11:44 am
Ternp : Ambient: 53°F Mix: 65'F
Unit Weight: 147.3 #/cu ft
Quantity Represented: 10 cu yds at 830 cu. yds. placed of a 1780 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Orifi City of Coppell (Coppell, I X) Attn: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, SET, CME Department Manager
11115 REPORTAPPIIFS ONLY TO I HE S'IANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
I'HP QJALnIES OF APPARFNI"I.Y IDENTICAL. OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOI ED, THESE REPORTS ARE FOR THE EXCLUSIVE_ USE OF TI IE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
ALuAnce
till GEOTECHhICRL
GROUP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Report Date: 02/15/2016 Previously Reported: 01/25/2016
Project: Freeport Parkway North
Location: Paving
Client City of Coppell
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Set: 10 of 18
Location: Station 22+58.39
Spec
Age Tested
Diameter
Area
Nbr
(date : days)
(in)
(in`)
A
01/18/16:3
6-00
28.27
B
01/22/16: 7
600
28.27
C
02/12/16:28
6.00
28.27
D
02/12/16:28
6.00
28.27
E
Type 3
Lab
5,160
TEST RESULTS
Material: Concrete
Date Sampled: 01/15/2016
Sampled By: Reyes, Jason
By Order Of: Walter
Order Number: 1770
LAB NO: 201195
Test Method: See Below
Report No: 201195
Page 10 of 18
Number of Specimens: 5
Maximum
Compressive
Average
Load
Cure
Strength
Strength
Tested
(Ibs)
Break Type
Loc
(PSI)
(PSI)
By
134,315
Type 3
Lab
4,750
4,750
JR
145,925
Type 3
Lab
5,160
5,160
MM
180,840
Type 5
Lab
6,400
JR
179,670
Type 1
Lab
6,350
6,380
JR
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
Comments
HOLD (see remarks) -
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 1.5 Inches Transported By: Tiseo
Air Content: 4.5% Source/Sampled At: Truck / Center
Mix Code: 2605M Plant: On -Site
Date Received: 01/16/2016 Truck/Ticket No: N1A/ 24370
Curing Method: Standard
Time Sampled: 12:25 pm
rime Batched: 12:08 pm
Temp.: Ambient: 60°F Mix: 67°F
Unit Weight: 145.9 #/cu ft
Quantity Represented: 10 cuyds. at 920 cu yds. placed of a 1780 cu. yd. total placement
Remarks.
Teat Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617
Onq Cily of Coppell (Coppell, l X) Attn Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
T J
.ii/!I<I.F�Z rf4✓
Perry C. Kakara, SET, CME Department Manager
[Ills REPORT APPI IFS ONI Y TO THE STANDARDS OR PROCEDURES INDICATED AND rO THE. SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE 01-
1 I
FTI Ir, QUAL11I1-S OF APPARLNTI Y IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURFS, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTLD, 1 HEST REPORTS ARF FOR TF IF EXCLUSIVE USE OF 111E ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION
nLUnrICL
Of-OTECHrIl AL
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 7524.7
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Report Date: 02/15/2016 Previously Reported: 01/25/2016
Project: Freeport Parkway North
Location: Paving
_Client- City of Coppell
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Set: 11 of 18
Location: Station 22+60
Spec:
Age Tested
Diameter
Area
Nbr
(date : days)
(in)
(int)
A
01/18/16:3
6.00
28.27
B
01/22/16:7
6.00
28.27
C
02/12/16: 28
6.00
2827
D
02/12/16: 28
6.00
2827
E
Type 3
Lab
5,160
TEST RESULTS
Material: Concrete
Date Sampled: 01/15/2016
Sampled By: Reyes, Jason
By Order Of: Walter
Order Number: 1770
LAB NO: 201195
Test Method: See Below
Report No: 201195
Page 11 of 18
Number of Specimens: 5
Maximum
Compressive
Average
Load
Cure
Strength
Strength
Tested
(Ibs)
Break Type
Loc
(PSI)
(PSI)
By
124,655
Type 3
Lab
4,410
4,410
JR
145,820
Type 3
Lab
5,160
5,160
MM
175,165
Type 5
Lab
6,200
JR
176.280
Type 5
Lab
6,230
6,210
JR
Type 1
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
Comments
HOLD (see remarks) -
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 1.5 Inches Transported By: Tiseo
Air Content: 4.2% Source/Sampled At: Truck I Center
Mix Code: 2605M Plant: On -Site
Crate Received: 01/16/2016 Truck/Ticket No: NIAI 24381
Curing Method: Standard
Time Sampled: 12:45 pm
rime Batched: 12:37 pm
Ternp.: Ambient: 61°F Mix: 66°F
Unit Weight: 145.4 #/cu ft
Quantity Represented: 10 cu. yds. at 1030 cu yds, placed of a 1780 cu, yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Orig: City of Coppell (Coppell, TX) At(n: Mr Rick O'Dell (1 -cc copy) Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, SET, CME Department Manager
1 HIS REPORT ADPL IES ONIY 10111E STANDARDS OR PROCEDURES INDICATE=D AND TO THE SAMPLE(S) TESTED ANDIOR OBSERVED AND ARE NOT NECESSARILY INDICATIVE- OF
I IiE QJALIIIES OF APPARFN rl_Y IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NO TED. THESE REPORI S ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION
RLLIAlYCE
QG0E0TECHhIC19L
GROUP
Consulting Engineering " Geotechnical Engineering ` Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Report Date: 02/15/2016 Previously Reported: 01/25/2016
Project: Freeport Parkway North
Location: Paving
Client City of Coppell ,
REPORT REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Set: 12 of 18
Location: Station 21+00
Spec:
Age Tested
Diameter
Area
Nbr
(date : days)
(in)
(in')
A
01/18/16: 3
600
28.27
B
01/22/16: 7
6.00
2827
C
02/12/16:28
6.00
28.27
D
02/12/16:28
6.00
28.27
E
Type 3
Lab
4,920
TEST RESULTS
Material: Concrete
Date Sampled: 01/15/2016
Sampled By: Reyes, Jason
By Order Of: Walter
Order Number: 1770
LAB NO: 201195
Test Method: See Below
Report No: 201195
Page 12 of 18
Number of Specimens: 5
Maximum
Compressive
Average
Load
Cure
Strength
Strength
Tested
(lbs)
Break Type
Loc
(PSI)
(PSI)
By
132,260
Type 3
Lab
4,680
4,680
JR
139,140
Type 3
Lab
4,920
4,920
MM
161,275
Type 4
Lab
5,700
JR
167,980
Type 5
Lab
5,940
5,820
JR
Type 1
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
Comments
HOLD (see remarks) -
lrrt
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 1.0 Inches Transported By: Tiseo
Air Content: 4.0% Source/Sampled At: Truck I Center
Mix Code: 2605M Plant: On -Site
Date Received: 01/16/2016 Truck /Ticket No: N/A/ 24391
Curing Method: Standard
Time Sampled: 1:15 pm
'Time Batched: 1:02 pm
Temp.: Ambient: 61°F Mix: 67°F
Unit Weight: 145.2 #/cu ft
Quantity Represented: 10 cu. yds. at 1130 cu. yds. placed of a 1780 cu. yd, total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Orifi Cily of Coppell (Coppell, 1 X)Atln: Mr. Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, SET, CME Department Manager
1 HIS REPORTAPPI_I[S ONLY TO TFIE. STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
TI IF QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NO TFD. 1 HESE REPORTS ARE FOR TFIE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
RLLIPMICE
GOEOTECFif11CRL
._ _OUP---__._.
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Report Date: 02/15/2016 Previously Reported: 01/25/2016
Project: Freeport Parkway North
Location: Paving
Client: City of Coppell
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Set: 13 of 18
Location: Station 20+50
Spec:
Age Tested
Diameter
Area
Nbr
(date : days)
(in)
(in')
A
01/18/16:3
6.00
28.27
B
01/22/16:7
6.00
28.27
C
02/12/16:28
6.00
28.27
D
02/12/16: 28
600
28.27
E
Type 3
Lab
5,050
TEST RESULTS
Material: Concrete
Date Sampled: 01/15/2016
Sampled By: Reyes, Jason
By Order Of: Walter
Order Number: 1770
LAB NO: 201195
Test Method: See Below
Report No: 201195
Page 13 of 18
Number of Specimens: 5
Maximum
Compressive
Average
Load
Cure
Strength
Strength
Tested
(Ibs)
Break Type
Loc
(PSI)
(PSI)
By
134,405
Type 3
Lab
4,750
4,750
JR
142,770
Type 3
Lab
5,050
5,050
MM
169,360
Type 4
Lab
5,990
JR
166,985
Type 3
Lab
5,910
5,950
JR
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
Comments
HOLD (see remarks) -
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 1.5 Inches Transported By: Tiseo
Air Conter%t: 4.2% Source/Sampled At: Truck / Center
Mix Code: 2605M Plant: On -Site
Date Received: 01/16/2016 Truck/Ticket No: N/A/ 24400
Curing Method: Standard
Time Sampled: 1:40 pm
Time Batched: 1:28 pm
Temp.: Ambient: 61°F Mix: 67°F
Unit Weight: 146.8 #/cu ft
Quantity Represented: 10 cu. yds at 1220 cu. yds. placed of a 1780 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Orig: City of Coppell (CoppeII, TX) Attn: Mr Rick O'DoI1 (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
yy��r
Perry C. Kakara, SET, CME Department Manager
11113 REPORT APPLIES ONLY TO THE S fANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
IT* OUAI IT IES OF APPARENI I Y IDENTICAL OR SIMILAR PRODUCI S OR PROCCDURES, NOR DO THEY REPRESENTAN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOI TD 1 HESE REPOR IS ARC FOR THC I-XCLUSIVE USE OF TI IE. ADDRESSED CLIENT AND ARE NOTTO BE REPRODUCED WITHOUT WRITTEN PERMISSION
RLLIHI'10E
GEOTECHf11CRl.
GROVP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Report Date: 02/15/2016 Previously Reported: 01/25/2016
Project: Freeport Parkway North
Location: Paving
Client: City of Coppell _
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Set: 14 of 18
Location: Station 19+50
Spec.
Age Tested
Nbr
(date : days)
A
01/18/16: 3
B
01/22/16:7
C
02/12/16:28
D
02/12/16:28
E
Strength
TEST RESULTS
Material: Concrete
Date Sampled: 01/15/2016
Sampled By: Reyes, Jason
By Order Of: Walter
Order Number: 1770
LAB NO: 201195
Test Method: See Below
Report No: 201195
Page 14 of 18
Number of Specimens: 5
Type 1
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
Comments
HOLD (see remarks) -
r
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 7.5 Inches Transported By: Tiseo
Air Content: 4.4% Source/Sampled At: Truck / Center
Mix Code: 2605M Plant: On -Site
Date Received: 01/16/2016 TruCrV Hcket No: NIA/ 24412
Curing Method: Standard
Time Sampled: 2:1b pm
Time Batched: 2:05 pm
Temp.: Ambient: 62°F Mix: 68°F
Unit Weight: 146.2 #/cu ft
Quantity Represented: 10 cu yds. at 1340 cu, yds, placed of a 1780 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Oriq: City of Coppell (Coppell, TX) At(n: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, SET, CME Department Manager
I IIIS REPORTAPPI IFS UNI Y TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
I HF O'JAI IT IFS OF APPARF.N TI Y IDFNI ICAI OR SIMII AR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED, T HESE REPORTS ARE FOR THF FXCL USIVE USE OF TI IE-_ ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION
Maximum
Compressive
Average
Diameter
Area
Load
Cure
Strength
Strength
Tested
(in)
(int)
(Ibs)
Break Type
Loc
(PSI)
(PSI)
By
600
28.27
132,750
Type 3
Lab
4,700
4,700
JR
6.00
28.27
136,580
Type 3
Lab
4,830
4,830
MM
6 00
2827
182,230
Type 5
Lab
6,450
JR
6.00
28.27
183,375
Type 5
Lab
6,490
6,470
JR
Type 1
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
Comments
HOLD (see remarks) -
r
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 7.5 Inches Transported By: Tiseo
Air Content: 4.4% Source/Sampled At: Truck / Center
Mix Code: 2605M Plant: On -Site
Date Received: 01/16/2016 TruCrV Hcket No: NIA/ 24412
Curing Method: Standard
Time Sampled: 2:1b pm
Time Batched: 2:05 pm
Temp.: Ambient: 62°F Mix: 68°F
Unit Weight: 146.2 #/cu ft
Quantity Represented: 10 cu yds. at 1340 cu, yds, placed of a 1780 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Oriq: City of Coppell (Coppell, TX) At(n: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, SET, CME Department Manager
I IIIS REPORTAPPI IFS UNI Y TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
I HF O'JAI IT IFS OF APPARF.N TI Y IDFNI ICAI OR SIMII AR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED, T HESE REPORTS ARE FOR THF FXCL USIVE USE OF TI IE-_ ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION
RILIAiYCE
�� G GEOTECFI1YICfiL
GROUP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Report Date: 02/15/2016 Previously Reported: 01/25/2016
Project: Freeport Parkway North
Location: Paving
Client: City of Coppell
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Set: 15 of 18
Location: Station 18+95
Spec
Age Tested
Diameter
Area
Nbr
(date : days)
(in)
(in')
A
01/18/16:3
6.00
28.27
B
01/22/16 7
600
28.27
C
02/12/16:28
6.00
28.27
D
02/12/16: 28
6.00
2827
E
Type 3
Lab
5,000
TEST RESULTS
Material: Concrete
Date Sampled: 01/15/2016
Sampled By: Reyes, Jason
By Order Of: Walter
Order Number: 1770
LAB NO: 201195
Test Method See Below
Report No: 201195
Page 15 of 18
Number of Specimens: 5
Maximum
Compressive
Average
Load
Cure
Strength
Strength
Tested
(Ibs)
Break Type
Loc
(PSI)
(PSI)
By
130,360
Type 3
Lab
4,610
4,610
JR
141,510
Type 3
Lab
5,000
5,000
MM
152,900
Type 6
Lab
5,410
JR
155,360
Type 6
Lab
5,490
5,450
JR
Type 1
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
t I I
Comments
HOLD (see remarks) -
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 1.0 Inches Transported By: Tiseo
Air Content: 4.2% Source/Sampled At: Truck / Center
Mix Code: 2605M Plant: On -Site
Date Received: 01/16/2016 Truck/Ticket No: NIA/ 24421
Curing Method: Standard
Time Sampled: 2:40 pm
rime Batched: 2:27 pm
Temp: Ambient: 63°F Mix: 68°F
Unit Weight: 146.1 #/cu ft
Quantity Represented: 10 cu. yds. at 1430 cu yds. placed of a 1780 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617
Orig: City of Coppell (Coppell, TX) Attn: Mr. Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, SET, CME Department Manager
l HIS REPORT APPIJES ONLY TO T'FIE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED ANDIOR OBSERVED AND ARE NOT NECESSARILY INDICATIVE 01 -
I
PI HE O'JALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NONA). THESE REPORTS ARE FOR 11L I-XCLUSIVE USE. OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION..
RLLIHfICE
GE0TECHf11CRL
GROUP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Report Date: 02/15/2016 Previously Reported: 01/25/2016
Project: Freeport Parkway North
Location: Paving
Client: City of Coppell
REPORT REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Set: 16 of 18
Location: Station 17+50
Spec.
Age Tested
Nbr
(date : days)
A
01/18/16: 3
B
01/22/16:7
C
02/12/16:28
D
02/12/16:28
E
Strength
TEST RESULTS
Material: Concrete
Date Sampled: 01/15/2016
Sampled By: Reyes, Jason
By Order Of: Walter
Order Number: 1770
LAB NO: 201195
Test Method: See Below
Report No: 201195
Page 16 of 18
Number of Specimens: 5
Type 1
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
Comments
HOLD (see remarks) -
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 1.5 Inches Transported By: Tiseo
Air Content: 4.4% Source/Sampled At: Truck / Center
Mix Code: 2605M Plant: On -Site
Date Received: 01/16/2016 Truck/Ticket No: NIA/ 24430
Curing Method: Standard
Time Sampled: 3:05 pm
Time Batched: 2:49 pm
Temp.: Ambient: 63°F Mix: 65°F
Unit Weight: 146.5 #/Cu ft
Quantity Represented: 10 cu, yds at 1520 cu, yds. placed of a 1780 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Ong: City or Coppell (Coppell, 1 X) Atln Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, SET, CME Department Manager
THIS REPORT APPI IFS ONLY TO T HE STANDARDS OR PROCEDURES INDICArEDAND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
'I Ii IF QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NO FEH H-IFSF REPORTS ARE FOR I IIF EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT To BE REPRODUCED WITHOUT WRITTEN PERMISSION.
Maximum
Compressive
Average
Diameter
Area
Load
Cure
Strength
Strength
Tested
(in)
(int)
(lbs)
Break Type
Loc
(PSI)
(PSI)
By
6.00
28.27
119,160
Type 3
Lab
4,210
4,210
JR
600
2827
129,535
Type 3
Lab
4,580
4,580
MM
6-00
28.27
176,240
Type 1
Lab
6,230
JR
6 00
28.27
172,385
Type 1
Lab
6,100
6,170
JR
Type 1
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
Comments
HOLD (see remarks) -
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 1.5 Inches Transported By: Tiseo
Air Content: 4.4% Source/Sampled At: Truck / Center
Mix Code: 2605M Plant: On -Site
Date Received: 01/16/2016 Truck/Ticket No: NIA/ 24430
Curing Method: Standard
Time Sampled: 3:05 pm
Time Batched: 2:49 pm
Temp.: Ambient: 63°F Mix: 65°F
Unit Weight: 146.5 #/Cu ft
Quantity Represented: 10 cu, yds at 1520 cu, yds. placed of a 1780 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Ong: City or Coppell (Coppell, 1 X) Atln Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, SET, CME Department Manager
THIS REPORT APPI IFS ONLY TO T HE STANDARDS OR PROCEDURES INDICArEDAND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
'I Ii IF QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NO FEH H-IFSF REPORTS ARE FOR I IIF EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT To BE REPRODUCED WITHOUT WRITTEN PERMISSION.
ALLIHIYCE
(110D GEOTKIif11CRL
GROUP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Report Date: 02/15/2016 Previously Reported: 01/25/2016
Project: Freeport Parkway North
Location: Paving
Client: City of Coppell
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
Set: 17 of 18
Location: Station 17+00
Spec:
Age Tested
Diameter
Area
Nbr
(date : days)
(in)
(in')
A
01/18/16:3
6.00
28.27
B
01/22/16: 7
6.00
2827
C
02/12/16:28
6.00
28.27
D
02/12/16:28
6.00
28.27
E
Type 3
Lab
4,940
TEST RESULTS
Material: Concrete
Date Sampled: 01/15/2016
Sampled By: Reyes, Jason
By Order Of: Walter
Order Number: 1770
LAB NO: 201195
Test Method: See Below
Report No: 201195
Page 17 of 18
Number of Specimens: 5
Maximum
Compressive
Average
Load
Cure
Strength
Strength
Tested
(Ibs)
Break Type
Loc
(PSI)
(PSI)
By Comments
123,880
Type 3
Lab
4,380
4,380
JR
139,730
Type 3
Lab
4,940
4,940
MM
173,885
Type 5
Lab
6,150
JR
175,775
Type 5
Lab
6,220
6,180
JR
Type 1
Specification
Strength: 3,600 psi @ 28 days
Slump: 1-3
Air Content: 3-6
HOLD (see remarks) -
Type 2 Type 3 Type 4 Type 5 Type 6
CONFORMS
Slump: 1.5 Inches Transported By: Tiseo
Air Content: 4.5% Source/Sampled At: Truck / Center
Mix Code: 2605M Plant: On -Site
Crate Received: 01/16/2016 Truck/Ticket No: N/A / 24442
Curing Method: Standard
Time Sampled: 3:35 pm
Time Batched: 3:18 pm
Temp : Ambient: 63°F Mix: 65°F
Unit Weight: 145.9 #/cu ft
Quantity Represented: 10 cu yds. at 1640 cu. yds. placed of a 1780 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617
Orig: Cily of Coppoll (Coppell, TX) Attn: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C, Kakara, SET, CME Department Manager
11118 REPORT APPI IES OWL Y 10 11 IF S TANDARDS OR PROCEDURES INDICA] ED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
[HL 0JAL I I IES OF APPAREN TI Y IDFNTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOT Ell. TI iESE REPORIS ARE. FOR 1 -HE EXCI USIVE USE OF THE ADDRESSED CLIENT AND ARE NOl TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
RILIAnCE
(01 G GEOTECHf11CRL
GRO P
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C15-0812
Date Sampled: 01/15/2016
Report Date: 02/15/2016 Previously Reported:
01/25/2016
Sampled By: Reyes, Jason
Project: Freeport Parkway North
By Order Of: Walter
Location: Paving
Order Number: 1770
Client: City of Coppell
—
REPORT REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
LAB NO: 201195
Test Method: See Below
TEST RESULTS
Report No: 201195
Page 18 of 18
Set: 18 of 18 Material: Concrete
Number of Specimens: 5
Location: Station 16+50
Maximum
Compressive
Average
Spec Age Tested Diameter Area Load
Cure Strength
Strength Tested
Nbr (date : days) (in) (int) (Ibs)
Break Type Loc (PSI)
(PSI) By Comments
A 01/18/16: 3 6.00 28.27 138,520
Type 3 Lab 4,900
4,900 JR
B 01/22/16: 7 6.00 28.27 152,670
Type 3 Lab 5,400
5,400 MM
C 02/12/16: 28 6-00 28.27 188,615
Type 4 Lab 6,670
JR
D 02/12/16: 26 6.00 28.27 187,420
Type 4 Lab 6,630
6,650 JR
E^ti
HOLD (see remarks) -
Type 1 Type 2 Type 3 Type 4 Type 5
Type 6
Specification
CONFORMS
Strength: 3,600 psi @ 28 days
Slump: 1-3
Slump: 1.5 Inches
Transported By: Tiseo
Air Content: 3-6
Air Content: 4.0%
Source/Sampled At: Truck I Center
Mix Code: 2605M
Plant: On -Site
t N N/A / 24450
Date Received: 01/16/2016 Truck/Tlcke o.
Curing Method: Standard
Time Sampled: 3:50 pm
Time Batched: 3:37 pm
Temp.: Ambient: 63°F Mix: 66°F
Unit Weight: 147 6 #/cu ft
Quantity Represented: 10 cu yds. at 1720 cu yds placed of a 1780 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless rioted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143,
C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and
cylinders were not capped per ASTM C617.
Orig Cdy of Coppell (Coppell, TX) Min: Mr Rick O'Dell (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, SET, CME Department Manager
I HIS REPORT APDL IES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMII-AR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE RE-PORIS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION