Loading...
ST0502B- LR160222ALLVI ICE Gff0TEChr11CML_ VV C7hour Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C15-0812 Report Date: 02/22/2016 Project: Freeport Parkway North Location: Ramp at intersection of Freeport Parkway and Sandy Lake, Sidewalk at Freeport Parkway and 121 Service Rd., Sampled; Northeast ramp at intersection of Freeport Parkway and Sandy Lake Client: REPORT: Material: City of Coppell REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST Concrete Spec Age Tested Nbr (date : days) A 02/19/16:7 B 02/19/16:7 C 03/11/16:28 D 03/11/16:28 Date Sampled: 02/12/2016 Sampled By: Perez, Jose By Order Of: Walter Order Number: 1770 Number of Specimens: 4 LAB NO: 203597 Test Method: See Below Specification Strength: 3,000 psi @ 28 days Slump: 3-5 Air Content: 3-6 Date Received: 02/13/2016 Curing Method: Standard Time Sampled: 11:25 am Time Batched: 10:23 am Temp.: Ambient: 61°F Mix: 64°F Slump: 4.25 Inches Air Content: 3.7% Mix Code: 1261 Transported By: LMC Source/Sampled At: Truck I Center Plant: 952 Truck/Ticket No: 5023 / 62992666 Quantity Represented: 9.5 cu. yds. at 9.5 cu. yds placed of a 38 0 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Onq: City of Coppell (Coppell, l X) Attn: Mr, Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C, Kakara, SET, CME Department Manager I I IIS REPORT APPI IFS ONI Y r0 IHE STANDARDS OR PROCEDURES INDICAI ED AND TO THE. SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF I HE QUALII IFS OF APPARPNTI Y IDENrICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED THESE REPORTS ARG FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION TEST RESULTS pgpj 1`8qi:1 203597 Maximum Compressive Average Diameter Area Load Cure Strength Strength Tested (in) (int) (Ibs) Break Type Loc (PSI) (PSI) By Comments 6.00 28.27 73,380 Type 2 Lab 2,600 JR 600 28.27 75,755 Type 2 Lab 2,680 2,640 JR 6.00 28.27 Lab 600 2827 Lab Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 3,000 psi @ 28 days Slump: 3-5 Air Content: 3-6 Date Received: 02/13/2016 Curing Method: Standard Time Sampled: 11:25 am Time Batched: 10:23 am Temp.: Ambient: 61°F Mix: 64°F Slump: 4.25 Inches Air Content: 3.7% Mix Code: 1261 Transported By: LMC Source/Sampled At: Truck I Center Plant: 952 Truck/Ticket No: 5023 / 62992666 Quantity Represented: 9.5 cu. yds. at 9.5 cu. yds placed of a 38 0 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Onq: City of Coppell (Coppell, l X) Attn: Mr, Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C, Kakara, SET, CME Department Manager I I IIS REPORT APPI IFS ONI Y r0 IHE STANDARDS OR PROCEDURES INDICAI ED AND TO THE. SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF I HE QUALII IFS OF APPARPNTI Y IDENrICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED THESE REPORTS ARG FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION