ST0502B- LR160304(10fl" WINCE � GEOTECHYICRL GROUP - --- Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C15-0812 Report Date: 03/04/2016 Project: Freeport Parkway North Location: Retaining wall, Panel #7, Sampled; Station 2+34 Client: City of Coppell _ REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST Material: Concrete Spec Age Tested Diameter Nbr (date : days) (in) A 03/03/16:7 6.00 B 03/03/16:7 6.00 C 03/24/16:28 6.00 D 03/24/16:28 6.00 Maximum Area Load (int) (Ibs) 28.27 122,800 28.27 125,360 28.27 28.27 Type 1 Specification Strength: 3,600 psi @ 28 days Slump: 3-5 Air Content: 0-3 TEST RESULTS Compressive Cure Strength Break Type Loc (PSI) Type 4 Lab 4,340 Type 4 Lab 4,430 Date Sampled: 02/25/2016 Sampled By: Maumalanga, John By Order Of: Walter Order Number: 1770 Number of Specimens: 4 LAB NO: 204325 Test Method: See Below Report No: 204325 Page 1 of 1 Average Strength Tested (PSI) By Comments JR 4,390 JR Lab Lab Type 2 Type 3 Type 4 Type 5 Type 6 Slump: 4.0 Inches Transported By: LMC Air Content: 2.0% Source/Sampled At: Truck I Center Mix Code: 1701 Plant: 956 Date Received: 02/26/2016 Truck/Ticket No: 1422 / 63098922 Curing Method: Standard Time Sampled: 1:10 pm Time Batched: 12:32 pm Temp.: Ambient: 57°F Mix: 65°F Unit Weight: 140 #/cu ft Quantity Represented: 9.5 cu. yds. at 9.5 cu. yds. placed of a 21.0 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, 01064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Orig: City of Coppell (Coppell, TX) Attn: Mr. Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. p RLLIAIYCE V cEorKrtnicnL Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 177Q File No: C15-0812 Date Sampled: 02/04/2016 Report Date: 03/04/2016 Previously Reported: 02/15/2016 Sampled By: Burtsell, Lloyd Project: Freeport Parkway North By Order Of: Walter Location: Rebar Inspection - Concrete - 50yds Order Number: 1770 Number of Client: City of Coppell Specimens: 4 REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 202974 Test Method: See Below TEST RESULTS Report No: 202974 Page 1 of 1 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (int) (Ibs) Break Type Loc (PSI) (PSI) By Comments A 02/07/16: 3 6.00 28.27 71,460 Type 3 Lab 2,530 2,530 JR B 02/11/16: 7 6.00 28.27 93,045 Type 3 Lab 3,290 3,290 JR C 03/03/16: 28 6.00 28.27 120,690 Type 3 Lab 4,270 JR D 03/03/16: 28 6.00 28.27 122,430 Type 3 Lab 4,331`10 4,300J11I JR CII IF Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: Slump: Slump: Transported By: Air Content: Air Content: NA Source/Sampled At: Mix Code: Plant: Truck/Ticket No: Curing Method: Time Sampled: Time Batched: Temp.: Ambient: Mix: Quantity Represented: Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Orig: City of Coppell (Coppell, TX) Attn: Mr Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.