ST0502B- LR160304 (2)RLLIfIhICE GEOTKHnICfiL CJRW Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C15-0812 Report Date: 03/04/2016 Project: Freeport Parkway North Location: Misc. Concrete Date Sampled: 02/26/2016 Sampled By: Maumalanga, John By Order Of: Walter Order Number: 1770 Client: City of Coppell _ REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 204327 Test Method: See Below TEST RESULTS Set: 1 of 2 Compressive Material: Concrete Location: Sidewalk Station 0+60 to 4+40, Sampled; Station 0+60 (PSI) Lab Maximum Spec Age Tested Diameter Area Load Nbr (date : days) (in) (int) (Ibs) Break Type A 03/04/16: 7 6.00 28.27 87,330 Type 2 B 03/04/16: 7 6.00 28.27 85,435 Type 3 C 03/25/16:28 D 03/25/16:28 6.00 28.27 6.00 28.27 Type 1 Specification Strength: 3,OQO psi @ 28 days Slump: 3-5 Air Content: 3-6 Date Received: 02/27/2016 Curing Method: Standard Time Sampled: 11:07 am Time Batched: 10:30 am Temp.: Ambient: 57°F Mix: 60°F fqy Compressive Cure Strength Loc (PSI) Lab 3,090 Lab 3,020 Lab Lab fqy Type 2 Type 3 Type 4 Slump: 4.0 Inches Air Content: 4.2% Mix Code: 1261 Report No: 204327 Page 1 of 2 Number of Specimens: 4 Average Strength Tested (PSI) By Comments JR 3.060 JR Type 5 Type 6 Transported By: LMC Source/Sampled At: Truck I Center Plant: 956 Truck/Ticket No: 7060 163098950 Quantity Represented: 9.5 cu. yds. at 9.5 cu, yds. placed of a 38.0 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Orig: City of Coppell (Coppell, TX) Attn: Mr Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION (40ALLIf11'ICE � 6EOTKtiI'IICRL QiOUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C15-0812 Report Date: 03/04/2016 Project: Freeport Parkway North Location: Misc. Concrete Client: City of Coppell _ REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST TEST RESULTS Set: 2 of 2 Material: Concrete Location: Retaining wall, Panel 8, Sampled; Panel 8 Maximum Spec Age Tested Diameter Area Load Nbr (date : days) (in) (int) (Ibs) Break A 03/04/16: 7 6.00 28.27 116,135 Type 3 B 03/04/16: 7 6.00 28.27 120,565 Type 3 C 03/25/16:28 D 03/25/16:28 6.00 28.27 6.00 28.27 Type 1 Compressive Cure Strength Type Loc (PSI) Lab 4,110 Lab 4,260 Lab Lab E�B I -] Type 3 Type 4 Type 5 Date Sampled: 02/26/2016 Sampled By: Maumalanga, John By Order Of: Walter Order Number: 1770 LAB NO: 204327 Test Method: See Below Report No: 204327 Page 2 of 2 Number of Specimens: 4 Average Strength Tested (PSI) By Comments JR 4,190 JR I Type 6 Specification Strength: 3,600 psi @ 28 days Slump: 3-5 Slump: 4.75 Inches Transported By: LMC Air Content: 0-3 Air Content: 1.6% Source/Sampled At: Truck / Center Mix Code: 1701 Plant: 952 Date Received: 02/27/2016 Truck/Ticket No: 1417 / 62993190 Curing Method: Standard Time Sampled: 2:15 pm Time Batched: 1:08 pm Temp.: Ambient: 61°F Mix: 68°F Unit Weight: 134 #/cu ft Quantity Represented: 9.5 cu. yds. at 9.5 cu. yds. placed of a 19.0 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Orig: City of Coppell (Coppell, TX) Attn: Mr Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C, Kakara, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION