Kyra Court- LR151105 8908 Ambassador Row,Dallas,TX 75247
Rone Engineering Texas Engineering Firm Registration,No.F-1572
Corporate Phone:(214)630-9745
111 11111111111011.111
Report of In-Place Density Testing
Client: JRose Architects Report No.: 14140347
2104 Cosmos Way Project No.: 1520637
Argyle, TX 76226 Date of Service: 10/19/2015
Report Date: 11/05/2015
Project: Kyra
Coppell, Texas
Services: Perform In-Place Density Testing
PROJECT DATA
Contractor: Standard Counts
Test Method:ASTM D-6938 Gauge: Troxler 3430 Moisture Density
Gauge Serial No: 21253 Current: 669 Current: 1581
Test Mode: DT Previous: 691 Previous: 1579
MOISTURE DENSITY RELATIONS
Maximum
Moisture Density Project Requirements
MID No. Description % (pcf) Moisture Density
14139978 Reddish Brown/Clay 15.2 110.3 NA
FIELD DENSITY TESTS
Test Probe MID Moisture Wet Density Dry Density Density
No Test Location Depth No. % (pcf) (pcf) (%max)
Utility Backfill
1 8"sanitary sewer line 1, Station 0+45, 5'below 8" 14139978 15.5 122.3 105.9 96
grade
Utility Backfill
2 8"sanitary sewer line 1, Station 0+55, 4'below 8" 14139978 16.8 129.6 111.0 101
grade
Utility Backfill
3 8"sanitary sewer line 1, Station 0+65, 3'below 8" 14139978 17.1 129.6 110.7 100
grade
Utility Backfill
4 8"sanitary sewer line 1, Station 0+75, 2'below 8" 14139978 16.1 125.5 108.1 98
grade
Utility Backfill
5 8"sanitary sewer line 1, Station 0+85, 1'below 8" 14139978 15.3 125.6 108.9 99
grade
Technician: Eric Hernandez Started: 10:00am Finished: 12:00pm Rone Engineering
Report Distribution:
Orig:JRose Architects(Argyle,TX)Attn:Mr.Jason Rose _
•
(1-ec copy)
1-ec Rone Engineering Project Managers t
Attn:Mr.Jason Creasy,CET Jason Creasy,CET
Project Manager
LIMITATIONS:The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition,appearance,etc.)or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services,Ltd.
(TM/JC)
Page 1 of 1