Kyra Court- LR151105 (2) 8908 Ambassador Row,Dallas,TX 75247 Rone Engineering Texas Engineering Firm Registration,No.F-1572 Corporate Phone:(214)630-9745 11111111111111111111 W 111111111111111111 Report of In-Place Density Testing Client: JRose Architects Report No.: 14140840 2104 Cosmos Way Project No.: 1520637 Argyle, TX 76226 Date of Service: 10/22/2015 Report Date: 11/05/2015 Project: Kyra Coppell, Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Standard Counts Test Method:ASTM D-6938 Gauge: Troxler 3440 Moisture Density Gauge Serial No: 26955 Current: 653 Current: 1773 Test Mode: DT Previous: 652 Previous: 1784 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements M/D No. Description % (pcf) Moisture Density 14139978 Reddish Brown/Clay 15.2 110.3 -2/+4 95 Min FIELD DENSITY TESTS Test Probe M/D Moisture Wet Density Dry Density Density No Test Location Depth No. % (pcf) (pcf) (%max) Utility Backfill 1 Sanitary sewer line 1, Station 1+10, 9'below 6" 14139978 18.9 126.2 106.1 96 grade Utility Backfill 2 Sanitary sewer line 1, Station 1+10, 8'below 6" 14139978 18.9 126.2 106.1 96 grade Utility Backfill 3 Sanitary sewer line 1, Station 1+10, 7'below 6" 14139978 19.0 126.7 106.5 97 grade Utility Backfill 4 Sanitary sewer line 1, Station 1+10, 6'below 6" 14139978 17.4 124.2 105.8 96 grade Utility Backfill 5 Sanitary sewer line 1, Station 1+10, 5'below 6" 14139978 16.3 122.5 105.3 96 grade Utility Backfill 6 Sanitary sewer line 1, Station 1+10, 4'below 6" 14139978 17.3 123.9 105.6 96 grade Utility Backfill 7 Sanitary sewer line 1, Station 1+10, 3'below 6" 14139978 15.6 122.1 105.6 96 grade LIMITATIONS:The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition,appearance,etc.)or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services,Ltd. (TM/JC) Page 1 of 3 8908 Ambassador Row,Dallas,TX 75247 'tone Engineering Texas Engineering Firm Registration,No.F-1572 Corporate Phone:(214)630-9745 Report of In-Place Density Testing Client: JRose Architects Report No.: 14140840 2104 Cosmos Way Project No.: 1520637 Argyle, TX 76226 Date of Service: 10/22/2015 Report Date: 11/05/2015 Project: Kyra Coppell, Texas Services: Perform In-Place Density Testing FIELD DENSITY TESTS Test Probe M/D Moisture Wet Density Dry Density Density No Test Location Depth No. % (pcf) (pcf) (%max) Utility Backfill 8 Sanitary sewer line 1, Station 1+10, 2'below 6" 14139978 18.1 125.1 105.9 96 grade Utility Backfill 9 Sanitary sewer line 1, Station 1+10, 1'below 6" 14139978 17.0 124.1 106.1 96 grade Utility Backfill 10 Sanitary sewer line 1, Station 3+00, 6'below 6" 14139978 18.1 125.7 106.4 97 grade Utility Backfill 11 Sanitary sewer line 1, Station 1+10, 5'below 6" 14139978 15.9 125.8 108.5 98 grade Utility Backfill 12 Sanitary sewer line 1, Station 1+10, 4'below 6" 14139978 16.1 124.2 107.0 97 grade Utility Backfill 13 Sanitary sewer line 1, Station 1+10, 3'below 6" 14139978 18.0 124.6 105.6 96 grade Utility Backfill 14 Sanitary sewer line 1, Station 1+10, 2'below 6" 14139978 17.3 124.9 106.5 97 grade Utility Backfill 15 Sanitary sewer line 1, Station 1+10, 1'below 6" 14139978 15.6 124.3 107.5 98 grade Utility Backfill 16 Sanitary sewer service, lot 5 and lot 6,6'below 6" 14139978 17.9 129.3 109.7 100 grade Utility Backfill 17 Sanitary sewer service, lot 5 and lot 6, 5'below 6" 14139978 17.2 129.0 110.1 100 grade Utility Backfill 18 Sanitary sewer service, lot 5 and lot 6,4'below 6" 14139978 18.9 129.7 109.1 99 grade LIMITATIONS:The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition,appearance,etc.)or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services,Ltd. (TM/JC) Page 2 of 3 8908 Ambassador Row,Dallas,TX 75247 Rone Engineering Texas Engineering Firm Registration,No.F-1572 Corporate Phone:(214)630-9745 10 Report of In-Place Density Testing Client: JRose Architects Report No.: 14140840 2104 Cosmos Way Project No.: 1520637 Argyle, TX 76226 Date of Service: 10/22/2015 Report Date: 11/05/2015 Project: Kyra Coppell, Texas Services: Perform In-Place Density Testing FIELD DENSITY TESTS Test Probe M/D Moisture Wet Density Dry Density Density No Test Location Depth No. % (pcf) (pcf) (%max) Utility Backfill 19 Sanitary sewer service, lot 5 and lot 6, 3'below 6" 14139978 17.3 129.4 110.3 100 grade Utility Backfill 20 Sanitary sewer service, lot 5 and lot 6, 2'below 6" 14139978 18.7 128.9 108.6 99 grade Utility Backfill 21 Sanitary sewer service, lot 5 and lot 6, 1'below 6" 14139978 17.8 128.4 109.0 99 grade Technician: James Fritch Started: 11:45am Finished: 02:OOpm Rone Engineering Report Distribution: Orig:JRose Architects(Argyle,TX)Attn:Mr.Jason Rose (1-ec copy) --- Air" 1-ec Rone Engineering Project Managers 410 Attn:Mr.Jason Creasy,CET Jason Creasy,CET Project Manager LIMITATIONS:The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition,appearance,etc.)or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services,Ltd. (TM/JC) Page 3 of 3