Kyra Court- LR151105 (2) 8908 Ambassador Row,Dallas,TX 75247
Rone Engineering Texas Engineering Firm Registration,No.F-1572
Corporate Phone:(214)630-9745
11111111111111111111 W 111111111111111111
Report of In-Place Density Testing
Client: JRose Architects Report No.: 14140840
2104 Cosmos Way Project No.: 1520637
Argyle, TX 76226 Date of Service: 10/22/2015
Report Date: 11/05/2015
Project: Kyra
Coppell, Texas
Services: Perform In-Place Density Testing
PROJECT DATA
Contractor: Standard Counts
Test Method:ASTM D-6938 Gauge: Troxler 3440 Moisture Density
Gauge Serial No: 26955 Current: 653 Current: 1773
Test Mode: DT Previous: 652 Previous: 1784
MOISTURE DENSITY RELATIONS
Maximum
Moisture Density Project Requirements
M/D No. Description % (pcf) Moisture Density
14139978 Reddish Brown/Clay 15.2 110.3 -2/+4 95 Min
FIELD DENSITY TESTS
Test Probe M/D Moisture Wet Density Dry Density Density
No Test Location Depth No. % (pcf) (pcf) (%max)
Utility Backfill
1 Sanitary sewer line 1, Station 1+10, 9'below 6" 14139978 18.9 126.2 106.1 96
grade
Utility Backfill
2 Sanitary sewer line 1, Station 1+10, 8'below 6" 14139978 18.9 126.2 106.1 96
grade
Utility Backfill
3 Sanitary sewer line 1, Station 1+10, 7'below 6" 14139978 19.0 126.7 106.5 97
grade
Utility Backfill
4 Sanitary sewer line 1, Station 1+10, 6'below 6" 14139978 17.4 124.2 105.8 96
grade
Utility Backfill
5 Sanitary sewer line 1, Station 1+10, 5'below 6" 14139978 16.3 122.5 105.3 96
grade
Utility Backfill
6 Sanitary sewer line 1, Station 1+10, 4'below 6" 14139978 17.3 123.9 105.6 96
grade
Utility Backfill
7 Sanitary sewer line 1, Station 1+10, 3'below 6" 14139978 15.6 122.1 105.6 96
grade
LIMITATIONS:The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition,appearance,etc.)or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services,Ltd.
(TM/JC)
Page 1 of 3
8908 Ambassador Row,Dallas,TX 75247
'tone Engineering Texas Engineering Firm Registration,No.F-1572
Corporate Phone:(214)630-9745
Report of In-Place Density Testing
Client: JRose Architects Report No.: 14140840
2104 Cosmos Way Project No.: 1520637
Argyle, TX 76226
Date of Service: 10/22/2015
Report Date: 11/05/2015
Project: Kyra
Coppell, Texas
Services: Perform In-Place Density Testing
FIELD DENSITY TESTS
Test Probe M/D Moisture Wet Density Dry Density Density
No Test Location Depth No. % (pcf) (pcf) (%max)
Utility Backfill
8 Sanitary sewer line 1, Station 1+10, 2'below 6" 14139978 18.1 125.1 105.9 96
grade
Utility Backfill
9 Sanitary sewer line 1, Station 1+10, 1'below 6" 14139978 17.0 124.1 106.1 96
grade
Utility Backfill
10 Sanitary sewer line 1, Station 3+00, 6'below 6" 14139978 18.1 125.7 106.4 97
grade
Utility Backfill
11 Sanitary sewer line 1, Station 1+10, 5'below 6" 14139978 15.9 125.8 108.5 98
grade
Utility Backfill
12 Sanitary sewer line 1, Station 1+10, 4'below 6" 14139978 16.1 124.2 107.0 97
grade
Utility Backfill
13 Sanitary sewer line 1, Station 1+10, 3'below 6" 14139978 18.0 124.6 105.6 96
grade
Utility Backfill
14 Sanitary sewer line 1, Station 1+10, 2'below 6" 14139978 17.3 124.9 106.5 97
grade
Utility Backfill
15 Sanitary sewer line 1, Station 1+10, 1'below 6" 14139978 15.6 124.3 107.5 98
grade
Utility Backfill
16 Sanitary sewer service, lot 5 and lot 6,6'below 6" 14139978 17.9 129.3 109.7 100
grade
Utility Backfill
17 Sanitary sewer service, lot 5 and lot 6, 5'below 6" 14139978 17.2 129.0 110.1 100
grade
Utility Backfill
18 Sanitary sewer service, lot 5 and lot 6,4'below 6" 14139978 18.9 129.7 109.1 99
grade
LIMITATIONS:The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition,appearance,etc.)or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services,Ltd.
(TM/JC)
Page 2 of 3
8908 Ambassador Row,Dallas,TX 75247
Rone Engineering Texas Engineering Firm Registration,No.F-1572
Corporate Phone:(214)630-9745
10
Report of In-Place Density Testing
Client: JRose Architects Report No.: 14140840
2104 Cosmos Way Project No.: 1520637
Argyle, TX 76226 Date of Service: 10/22/2015
Report Date: 11/05/2015
Project: Kyra
Coppell, Texas
Services: Perform In-Place Density Testing
FIELD DENSITY TESTS
Test Probe M/D Moisture Wet Density Dry Density Density
No Test Location Depth No. % (pcf) (pcf) (%max)
Utility Backfill
19 Sanitary sewer service, lot 5 and lot 6, 3'below 6" 14139978 17.3 129.4 110.3 100
grade
Utility Backfill
20 Sanitary sewer service, lot 5 and lot 6, 2'below 6" 14139978 18.7 128.9 108.6 99
grade
Utility Backfill
21 Sanitary sewer service, lot 5 and lot 6, 1'below 6" 14139978 17.8 128.4 109.0 99
grade
Technician: James Fritch Started: 11:45am Finished: 02:OOpm Rone Engineering
Report Distribution:
Orig:JRose Architects(Argyle,TX)Attn:Mr.Jason Rose
(1-ec copy) --- Air"
1-ec Rone Engineering Project Managers 410
Attn:Mr.Jason Creasy,CET Jason Creasy,CET
Project Manager
LIMITATIONS:The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition,appearance,etc.)or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services,Ltd.
(TM/JC)
Page 3 of 3