Loading...
Kyra Court- LR151208 8908 Ambassador Row,Dallas,TX 75247 Rone Engineering Texas Engineering Firm Registration,No.F-1572 Corporate Phone:(214)630-9745 Report of In-Place Density Testing Client: JRose Architects Report No.: 14143851 2104 Cosmos Way Project No.: 1520637 Argyle, TX 76226 Date of Service: 12/08/2015 Report Date: 12/10/2015 Project: Kyra Coppell, Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Standard Counts Test Method:ASTM D-6938 Gauge: Troxler 3440 Moisture Density Gauge Serial No: 26955 Current: 650 Current: 1784 Test Mode: DT Previous: 651 Previous: 1767 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements M/D No. Description % (pcf) Moisture Density 14139978 Reddish Brown/Clay 15.2 110.3 Optimum +4 95 min FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pcf) (pcf) (%max) Utility backfill 1 10"water line, Station 0+00, 3'below grade 6" 14139978 18.9 128.4 108.0 98 Utility backfill 2 10"water line, Station 0+00, 2'below grade 6" 14139978 19.0 127.2 106.9 97 Utility backfill 3 10"water line, Station 0+00, 1'below grade 6" 14139978 18.5 127.2 107.3 97 Utility backfill 4 10"water line, Station 0+00, final 6" 14139978 19.1 128.3 107.7 98 Utility backfill 5 10"water line, Station 2+50, 2'below grade 6" 14139978 17.2 128.3 109.5 99 Utility backfill 6 10"water line, Station 2+50, 1'below grade 6" 14139978 16.4 126.9 109.0 99 Utility backfill 7 10"water line, Station 6+00, 2'below grade 6" 14139978 17.5 129.1 109.9 100 Utility backfill 8 10"water line, Station 6+00, 1'below grade 6" 14139978 17.9 128.3 108.8 99 Utility backfill 9 10"water line, Station 8+00, 2'below grade 6" 14139978 19.2 128.4 107.7 98 LIMITATIONS:The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition,appearance,etc.)or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services,Ltd. (TM/JC) Page 1 of 2 TX 76247 Ro n e Engineering Texas 8908 Ambassador Row,Dallas,Engineering Firm Registration,No.o.F-1572-1572 Corporate Phone:(214)630-9746 W 11111.1.11111111 Report of In-Place Density Testing Client: JRose Architects Report No.: 14143851 2104 Cosmos Way Project No.: 1520637 Argyle, TX 76226 Date of Service: 12/08/2015 Report Date: 12/10/2015 Project: Kyra Coppell, Texas Services: Perform In-Place Density Testing FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pcf) (pcf) (%max) Utility backfill 10 10"water line, Station 8+00, 1'below grade 6" 14139978 19.0 127.8 107.4 97 Utility backfill 11 Water service, lot 3, 2'below grade 6" 14139978 16.5 128.5 110.3 100 Utility backfill 12 Water service, lot 3, 1'below grade 6" 14139978 18.6 128.9 108.7 99 Utility backfill 13 Water service, lot 19, 2'below grade 6" 14139978 18.5 127.9 107.9 98 Utility backfill 14 Water service, lot 19, 1'below grade 6" 14139978 17.8 126.7 107.6 98 Technician: James Fritch Started: 03:45pm Finished: 05:30pm Rone Engineering Report Distribution: Orig:JRose Architects(Argyle,TX)Attn:Mr.Jason Rose • (1-ec copy) Ow" __ 1-ec Rone Engineering Project Managers f Attn:Mr.Jason Creasy,CET Jason Creasy,CET Project Manager LIMITATIONS:The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition,appearance,etc.)or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services,Ltd. (TM/JC) Page 2 of 2