Loading...
Kyra Court- LR160104 8908 Ambassador Row,Dallas,TX 75247 Rone Engineering Texas Engineering Firm Registration,No.F-1572 Corporate Phone:(214)630-9745 N.1111111111111111.1 Report of In-Place Density Testing Client: JRose Architects Report No.: 14144889 2104 Cosmos Way Project No.: 1520637 Argyle, TX 76226 Date of Service: 12/23/2015 Report Date: 01/04/2016 Project: Kyra Coppell, Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Standard Counts Test Method:ASTM D-6938 Gauge: Troxler 3440 Moisture Density Gauge Serial No: 26955 Current: 649 Current: 1781 Test Mode: DT Previous: 660 Previous: 1783 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements M/D No. Description % (pcf) Moisture Density 14139978 Reddish Brown/Clay 15.2 110.3 Optimum +4 95 Min FIELD DENSITY TESTS Test Probe M/D Moisture Wet Density Dry Density Density No Test Location Depth No. / (pcf) (pcf) (% max) Utility Backfill 1 Storm drain line A, Station 1+50, 1'below grade 6" 14139978 19.0 129.4 108.7 99 Utility Backfill 2 Storm drain line A, Station 1+00, 3'below grade 6" 14139978 18.3 124.1 104.9 95 Utility Backfill 3 Storm drain line A, Station 1+00,2'below grade 6" 14139978 17.8 126.8 107.6 98 Utility Backfill 4 Storm drain line A, Station 1+00, 1'below grade 6" 14139978 17.6 123.8 105.3 96 Utility Backfill 5 Storm drain line A, Station 0+50,4'below grade 6" 14139978 18.2 125.2 105.9 96 Utility Backfill 6 Storm drain line A, Station 0+50, 3'below grade 6" 14139978 19.2 127.9 107.3 97 Utility Backfill 7 Storm drain line A, Station 0+50, 2'below grade 6" 14139978 18.8 128.4 108.1 98 Utility Backfill 8 Storm drain line A, Station 0+50, 1'below grade 6" 14139978 17.6 128.7 109.4 99 Technician: James Fritch Started: 02:15pm Finished: 04:OOpm Rone Engineering Report Distribution: Orig:JRose Architects(Argyle,TX)Attn:Mr.Jason RoseIIIP _ (1-ec copy) 1-ec Rone Engineering Project Managers I Attn:Mr.Jason Creasy,CET Jason Creasy,CET Project Manager LIMITATIONS:The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition,appearance,etc.)or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services,Ltd. (PH/JC) Page 1 of 1