Loading...
Hammond- LR150723 • Rone Engineering 8908 Ambassador Row,Dallas,TX 75247 Texas Engineering Firm Registration,No.F-1572 Corporate Phone:(214)630-9745 Report of In-Place Density Testing Client: JRose Architects Report No.: 14132935 230 Lake Drive Project No.: 1519926 Mount Vernon, TX 75457 Date of Service: 07/21/2015 Report Date: 07/23/2015 Project: Hammond Street Residential Development Coppell, Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Standard Counts Test Method:ASTM D-6938 Gauge: Troxler 3440+ Moisture Density Gauge Serial No: 60002 Current: 710 Current: 2619 Test Mode: DT Previous: 714 Previous: 2621 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements M/D No. Description % (pcf) Moisture Density 14118887 Dark Brown/Clay with Sand&Trace of Organics 20.9 99.0 Optimum+4 95-100 FIELD DENSITY TESTS Test Probe M/D Moisture Wet Density Dry Density Density No Test Location Depth No. % (pcf) (pcf) (%max) Utility Backfill 1 8"sanitary sewer line 1, Station 4+00, 2'below 8" 14118887 23.9 118.6 95.7 97 grade Utility Backfill 2 8"sanitary sewer line 1, Station 4+00, 1'below 8" 14118887 21.8 119.5 98.1 99 grade Utility Backfill 3 8"sanitary sewer line 1, Station 4+00,final 8" 14118887 23.0 119.1 96.8 98 Utility Backfill 4 8"sanitary sewer line 1, Station 1+00, 3'below 8" 14118887 22.5 118.5 96.7 98 grade Utility Backfill 5 8"sanitary sewer line 1, Station 1+00, 2'below 8" 14118887 22.8 120.8 98.4 99 grade Utility Backfill 6 8"sanitary sewer line 1, Station 1+00, 1'below 8" 14118887 22.2 120.9 98.9 100 grade Utility Backfill 7 8"sanitary sewer line 1, Station 1+00,final 8" 14118887 22.2 121.3 99.3 100 LIMITATIONS:The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition,appearance,etc.)or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services,Ltd. (JO/JO) Page 1 of 2 • 8908 Ambassador Row,Dallas,TX 75247 Rone Engineering Texas Engineering Firm Registration,No.F-1572 Corporate Phone:(214)630-9745 Report of In-Place Density Testing Client: JRose Architects Report No.: 14132935 230 Lake Drive Project No.: 1519926 Mount Vernon, TX 75457 Date of Service: 07/21/2015 Report Date: 07/23/2015 Project: Hammond Street Residential Development Coppell, Texas Services: Perform In-Place Density Testing FIELD DENSITY TESTS Test Probe M/D Moisture Wet Density Dry Density Density No Test Location Depth No. % (pcf) (pcf) (%max) Utility Backfill 8 36"RCP line A, Station 0+20, final 8" 14118887 20.9 117.4 97.1 98 Technician: DJ Martin Started: 08:30am Finished: 10:15am Rone Engineering Report Distribution: A Orig:JRose Architects(Mount Vernon,TX)Attn:Ms.Barb Rose i ,'r (1-ec copy) i..rt+.. 1-ec Rone Engineering Project Managers Attn:Mr.Josh Oliver 1-ec JRose Architects Attn:Mr.Jason Rose Josh Oliver,EIT Project Manager LIMITATIONS:The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition,appearance,etc.)or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services,Ltd. (JO/JO) Page 2 of 2