Hammond- LR150904 •
8908 Ambassador Row,Dallas,TX 75247
Roane Engineering Texas Engineering Firm Registration,No.F-1572
Corporate Phone:(214)630-9745
Report of In-Place Density Testing
Client: JRose Architects Report No.: 14136854
2104 Cosmos Way Project No.: 1519926
Argyle, TX 76226 Date of Service: 09/03/2015
Report Date: 09/04/2015
Project: Hammond Street Residential Development
Coppell, Texas
Services: Perform In-Place Density Testing
PROJECT DATA
Contractor: Standard Counts
Test Method:ASTM D-6938 Gauge: Troxler 3440 Moisture Density
Gauge Serial No: 25199 Current: 657 Current: 2006
Test Mode: DT Previous: 656 Previous: 2001
MOISTURE DENSITY RELATIONS
Maximum
Moisture Density Project Requirements
M/D No. Description % (pcf) Moisture Density
14134794 Crushed/Concrete 11.7 123.3 -2/+2 95 Min
FIELD DENSITY TESTS
Test Probe M/D Moisture Wet Density Dry Density Density
No Test Location Depth No. % (pcf) (pcf) (%max)
Flex Base
1 North alley entrance,40'west of Hammond 6" 14134794 13.1 134.0 118.5 96
Flex Base
2 West alley access road, 250'from Hammond 6" 14134794 12.6 135.7 120.5 98
Flex Base
3 South alley entrance, 60'west of Hammond 6" 14134794 11.8 131.2 117.3 95
Technician: Tony Sitton Started: 10:15am Finished: 11:45am Rone Engineering
Report Distribution:
Orig:JRose Architects(Argyle,TX)Attn:Ms. Barb Rose r '/ "4,,.__-
(1-ec copy)
1-ec Rone Engineering Project Managers Attn:Mr.Josh Oliver
1-ec JRose Architects Attn:Mr.Jason Rose Josh Oliver,EIT
Project Manager
LIMITATIONS:The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition,appearance,etc.)or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services,Ltd.
(JO/J0)
Page 1 of 1