Copperstone-LR 930129MAXIM ENGINEERS, INC. Engineering and Environmental Consultants 2342 Fabens · P.O. Box 59902 · Dallas, TX 75229 (214) 247-7575 · FAX (214) 484-5804 MOISTURE DENSITY RELATIONSHIP REPORT Report Date To Project # Project Identification Test Procedure 01/29/93 Sample Date Centex Real Estate 0392002041 Copper Stone - Coppell, Texas Moisture/Density Relations of Soil ASTM D-698A, ASTM D-4318, ASTM D-1140 01/19/93 Results Rammer Type ................................... Mechanical Preparation Procedure ............................. Moist Material Description .............................. Dark brown clay with roots Unified Soil Classification ........................... CH Material Origin .................................. On-Site Liquid Limit .................................... 52 Plastic Limit .................................... 20 Plasticity Index .................................. 32 Percent Passing No. 200 Sieve ....................... 96 percent Maximum Density ................................ 92.8 lbs./cu.ft. Optimum Moisture ............................... 25.0 percent Technician: R. Pleasant /br Centex Real Estate Corporation - Derek Earle, P.E. Rodman Excavation - Rod Vilhouer City of Coppell - Larry Davis ~' City of Coppell - Garreth D. Campbell, Sr. This report is for the sole use of the dient addressed. The use of our company name must receive our prior written consent. This report applies only to the sample tested, and does not necessarily representidentical or similar samples. 01092