Coppell Heights- DRC1501161 of 1 COPPELL CITY OF COPPELL COPPELL * , DRC REPORT 1/28/2015 �,. M review only. They are not the result of a full Building Protect ID RPNR-15-0004 Protect No. Coppell Heights Addition, Lots 9C1 & 9C2, Block r Address 920 5 Belt Line Rd Proiect Type Replat- Non -Res Application Date 1/16/2015 Case Manaoer NO Steer Proiect Description , to allow the subdivision of the existing property into two lots (one building per lot) and provide for shared packing, dumpers and access on 2.6 acres Tim Oates 1/26/2015 1 of 1 Agency Reviewed By Review Data Comments Building Inspection Jack Foster 1/28/2015 1. These Comments are the result of a site plan review only. They are not the result of a full Building plan review. Further comments should be expected when building and related plans are submitted with permit application(s). 2. Will there be a shared parking agreement? 3. Parking may be an issue due to possibility of restaurant with drive-through. Engineering Fire Administration Tim Oates 1/26/2015 Fire lane easement shall encompass the entire width of the three (3) drive openings to city streets. Once the fire lane intersects the tat drive aisle, it may taper down to 24-8. Parks and Recreation John Elias 1/2842015 No Comments Planning Department Matt Steer 1/28/2015 1. Label all existing and proposed easements. 2. Rename to Lot 9C1 & 9C2, Block A, Coppell Heights Rapist and revise all areas of plat accordingly. 3. Move vicinity map to the top right corner of the plat. 4. Include owners signature blank. below the owners dedication. 5. include bearing and distance of property line on Sanders Loop. COPPELL as Proect ID Address Proiect Tvce Aoolicatlon Date Case Manager PD -15-0003 920 S Bell Dns Rd Re -Zoning PD 1/182015 Mad Steer CITY OF COPPELL COP FELL DRC REPORT w Proiect Name PD 278R, Copped Heights Add, Lots 9C1 8 9C2, Proiect Description a zoning change request from R(Retail) to Planned Development 278R (Planned Development 278-RetaiO to allow the subdivision of the existing property into two lots (one building per lot) and provide for shared parking, dumpers and access and to establish a landscape variance Agency Reviewed By Building Inspection Jack Foster Po r---���4V-� Engineering Fire Administration Tim Oates Parks and Recreation John Elias Planning Department Matt Steer 1 of 2 Review Data Comments 1/28/2015 1. These Comments are the result of a site plan review only. They are not the result of a full Building plan review. Further comments should be expected when building and related plans are submitted with permit application(s). 2. Need dumpster for Lot 9D 3. Curb not shown at SE corner of lot. 1/26/2015 The Fire Department does not have any issues with the proposed zoning change request. 1/28/2015 No Comments 1/28/2015 1. Revise lot naming convention to "Lots 9C1 8 91 Block A, Copped Heights Addition". Ensure all documents and plans are revised accordingly. 2. If there are shared utilities, please include in private agreement. Site Plan: 1. Additional signage is not allowed on Sanders Loop. 2. Monument Sign height dimension is measured from peak of sign to grade; therefore, proposal is too large. 3. Show all setbacks and existing and proposed easements on site plan. 4. Label property to the north (Lot 9A, Block A) as Retail zoning. 5. Label lots and buildings within there respective footprints on plan. 6. Add parking to the northeast corner of parking lot northeast of Building A, as the total parking provided is two spaces deficient for medical office. 7. Correct proposed property line on site plan. 8. Note that no signage will be allowed on the east elevation of Building A and south elevation of Building B as this is considered the rear of the buildings. 9. Dimension parking spaces and all building setbacks. 10. Verify 8.2' dimension on west property line of building A. 11. Include a PD Conditions table outlining the sideyard setback deficiencies and the 10' perimeter COPPELL -MW,k * Agency CITY OF COPPELL DRC REPORT COPPELL Reviewed By Review Date comments buffer requirement not being met on the mutual property line of both lots. 12. Remove the off premise advertaing from the draft agreement as this is not allowed. Tree Survey: 1. Several tree deficiencies on both lots are evident and should be addressed on the Landscape Plan. Landscape Plan: 1. The Landscape Plan needs to include the entire property not just Building A. 2. Landscape summary for area calculations: Required Area: a. Perimeter is 15' adjacent to rights-cf-way and 10' adjacent to interior lots; b. Interior (parking lot landscaping) is 10% of parking paved area including all abutting sidewalks and ensure that the end of each parking row has a landscape island (min. 150 square feet) with no more than 15 spaces without an island; c. Nonvehicular landscape area is 15% (site area - building area). These are all stand alone categories and cannot be counted more than once. 3. Landscape summary for calculations and tree requirements: a. Revise tree calculations to show 18 required trees for interior as there are 18 existing parking islands that can accommodate and overstory tree, b. 35 total perimeter trees as one tree is required per 40 feet along the Belt Line frontages and one tree per 50 feet along the interior property lines, and c. nonvehicular open space requires 1 tree per 2,500 square feel.