2014_1029 CITY OF COPPELL WATER UTILITIES CUSTOMER SERVICE INSPECTI01� Residential � Commercial ❑ TNRCC ID#0570040 ✓ I r� } , �o Ul{���/ ,upon inspection of the pnvate water distribution facilities located at (� �G.�'I��sv� , which is connected to the City of Coppell Water System, do hereby certify that,to the best of my knowledge: In Non- N/A Complianc Compliance (1) No direct connection between the public drinking water supply and a potential � � ❑ source of contamination exists. Potenrial sources of contamination are isolated from the public water system by an air gap or an appropriate backflow prevenrion assembly in accordance with Commission regularions. (2) No cross-connection between the public drinking water supply and a private water �+ ❑ ❑ system exists. Where an actual air gap is not maintained between the public water supply and private water supply, an approved reduced pressure-zone backflow� prevenrion assembly is properly installed and a service agreement exists for annual inspection and testing by a certified backflow prevention device tester. (3) No connecrion exists which would allow the retum of water used for condensing C3 ❑ ❑ cooling or industrial processes back to the public water supply. (4) No pipe or pipe fitting which contains more than 8.0%lead exists in private water {�' ❑ ❑ distribution faciliries installed on or after July 1, 1988. (5) No solder or flux which contains more than 0.2% lead exists in private water C�_ ❑ ❑ distribution facilities installed on or after July 1, 1988. Water service shall not be provided or restored to the private water distribution facilities unril the above condirions are determined to be in compliance. I certify that the following materials will be used in the installation of the private water distribution facilities located at �7�p ��'�lG�GY� and that the inspector will validate compliance during the inspecrion process: Service lines Lead � Copper ❑ PVC ❑ Other � Solder Lead ❑ Lead Free Ca� Solvent Weld ❑ Other ❑ I recognize that this document shall become a permanent record of the aforementioned Public Water System and that I am legally res onsible for the validity of the information I have provided. � ��- 9a�� nature of Licensed Plumber Registration Numbei GUS �'.S /� r �.�' /� Type of egistration Date I recognize that this document shall become a permanent record of the aforementioned Public Water System and that I am legally responsible for the validity of the information provided. Signature of Inspector Registration Number Type of Registration Date White-Customers Copy Yellow-City's Copy Pink-lospedors Copy