DCT Fellowship- LR160209 2424 STUTZ DR.  SUITE 400  DALLAS, TX 75235  TEL [214] 350 5600  FAX [214] 350 0019 REPORT OF FIELD DENSITY TESTS DCT Freeport West Bethel Road and Creekview Drive Coppell, Texas REPORTED TO: DCT Industrial Trust 5430 LBJ Freeway, Suite 1030 Dallas, Texas 75240 ATTN: Mr. Joe Williams REPORT NO. 5 REPORT DATE: 02-09-16 REG PROJECT NO. 20922 TECHNICIAN: A. Chavez PAGE: 1 of 3 CONTRACTOR: FCL Builders Texas Proctor No. ASTM Standard Description Optimum Moisture, % Maximum Density, PCF 1 D-698 Dark brown clay 22.1 98.9 2 D-698 Yellowish brown clayey sand 12.4 117.4 3 D-698 Reddish brown sandy clay w/trace gray clay 13.7 112.3 4 D-698 Yellowish brown sandy clay 16.6 109.7 5 D-698 Dark brown & reddish brown clay 17.4 106.3 6 D-698 Brown sandy clay w/trace gray & red clay 14.0 113.6 Test No. Date Location Depth Below Final S. G. (feet) Field Density (pcf) Field Moisture (%) Proctor ID Compaction Level (%) 1 01-25-16 Bldg Pad: J.2-4.5 6.0 111.2 17.4 6 97.9 2 Bldg Pad: J.2-4.5 5.0 105.8 19.0 6 93.1 3 Bldg Pad: G.5-4.3 6.0 105.5 16.8 6 92.9 4 Bldg Pad: G.5-4.3 5.0 108.1 15.1 6 95.2 5 Bldg Pad: E.9-4.8 6.0 108.5 17.2 6 95.5 6 Bldg Pad: E.9-4.8 5.0 109.9 15.8 6 96.7 7 Bldg Pad: D.1-4.5 7.0 110.9 15.7 6 97.6 8 Bldg Pad: D.1-4.5 6.0 108.8 15.7 6 95.8 9 Bldg Pad: B.9-4.6 7.0 110.3 15.2 6 97.1 10 Bldg Pad: B.9-4.6 6.0 110.6 18.0 6 97.3 11 Bldg Pad: A.7-4.5 8.0 107.8 16.0 6 94.9 12 Bldg Pad: A.7-4.5 7.0 110.0 17.7 6 96.8 13 Bldg Pad: J.8-4.1 4.0 108.2 16.1 6 95.2 14 Bldg Pad: H-4.8 4.0 107.0 18.3 6 94.2 15 Bldg Pad: F.2-4.5 4.0 109.8 16.6 6 96.6 16 Bldg Pad: D.8-4.4 5.0 111.1 15.4 6 97.8 17 Bldg Pad: C-4.1 5.0 109.1 17.1 6 96.0 18 Bldg Pad: A.5-4.8 6.0 109.1 16.6 6 96.0 19 Bldg Pad: J.5-4.5 3.0 104.9 19.1 6 92.3 20 Bldg Pad: G.8-4.8 3.0 110.1 15.2 6 96.9 21 Bldg Pad: F-4.2 3.0 108.1 16.7 6 95.1 22 Bldg Pad: D.5-4.5 4.0 106.2 18.5 6 93.5 REPORT NO. 5 REPORT DATE: 02-09-16 REG PROJECT NO. 20922 PAGE: 2 of 3 Test No. Date Location Depth Below Final S. G. (feet) Field Density (pcf) Field Moisture (%) Proctor ID Compaction Level (%) 23 01-25-16 Bldg Pad: B.5-4.5 4.0 110.5 15.8 6 97.3 24 Bldg Pad: A.5-4.5 5.0 107.7 15.2 6 94.8 25 Bldg Pad: A.5-4.5 4.0 105.1 18.0 6 92.5 26 01-27-16 Bldg Pad: J.1-4.8 2.0 112.1 15.0 2 95.5 27 Bldg Pad: J.1-4.8 1.0 111.1 14.8 2 94.6 28 Bldg Pad: G.9-4.2 2.0 108.8 16.0 6 95.8 29 Bldg Pad: G.9-4.2 1.0 105.8 18.9 6 93.1 30 Bldg Pad: F-4.5 3.0 112.2 15.1 2 95.6 31 Bldg Pad: F-4.5 2.0 108.6 17.2 2 92.5 32 Bldg Pad: D.8-4.3 3.0 109.0 15.5 2 92.8 33 Bldg Pad: D.8-4.3 2.0 108.3 16.2 2 92.2 34 Bldg Pad: C.5-4.5 3.0 110.7 15.3 6 97.4 35 Bldg Pad: C.5-4.5 2.0 111.0 16.7 6 97.7 36 Bldg Pad: B.1-4.7 3.0 104.7 15.8 6 92.2 37 Bldg Pad: B.1-4.7 2.0 108.0 18.0 6 95.1 38 Bldg Pad: J.2-3.5 8.0 111.0 15.0 6 97.7 39 Bldg Pad: J.2-3.5 7.0 104.5 15.3 6 92.0 40 Bldg Pad: H-3.2 8.0 105.8 17.1 6 93.1 41 Bldg Pad: H-3.2 7.0 111.1 18.0 6 97.8 42 Bldg Pad: F.8-3.8 8.0 108.8 16.6 6 95.8 43 Bldg Pad: F.8-3.8 7.0 105.8 18.8 6 93.1 44 Bldg Pad: E.2-3.5 8.0 107.9 16.9 6 95.0 45 Bldg Pad: E.2-3.5 7.0 104.5 19.0 6 92.0 46 Bldg Pad: D-3.8 8.0 94.1 24.1 1 95.1 47 Bldg Pad: D-3.8 7.0 92.2 23.6 1 93.2 48 Bldg Pad: B.8-3.5 8.0 95.5 25.1 1 96.6 49 Bldg Pad: B.8-3.5 7.0 92.2 23.1 1 93.2 50 Bldg Pad: A.5-3.5 8.0 94.8 25.3 1 95.8 51 Bldg Pad: A.5-3.5 7.0 93.9 23.9 1 94.9 52 Bldg Pad: J.3-3.5 6.0 109.8 16.0 2 93.5 53 Bldg Pad: H-3.8 6.0 113.0 14.5 2 96.2 54 Bldg Pad: F.9-3.2 6.0 111.1 15.9 2 94.6 55 Bldg Pad: E.3-3.5 6.0 108.7 14.0 2 92.6 56 Bldg Pad: D-3.8 6.0 110.2 15.5 2 93.9 57 Bldg Pad: C-3.5 6. 112.5 14.8 2 95.8 58 Bldg Pad: A.3-3.5 6.0 109.7 16.2 2 93.4 Comments: Where tested, materials were in compliance with project specifications. REPORT NO. 5 REPORT DATE: 02-09-16 REG PROJECT NO. 20922 PAGE: 3 of 3 E-Mail Distribution: (1) DCT Industrial Trust/ Mr. Joe Williams (1) DCT Industrial Trust/ Mr. Sophia Montemayor (1) FCL Builders Texas/Mr. Drew Hanlon (1) Pross Design Group/Mr. Bobby Pross (1) City of Coppell/Mr. Marcus Marion (1) Pacheco Koch/Mr. Clayton Strolle Submitted by: REED ENGINEERING GROUP, LTD. Registration Number F-3114 Bill Woolwine Sr. Manager, CMT BW/mg