Loading...
ST0502A- LR160316RLLIfiIYCE QEOTECHI'IICRL -- GR UP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 4448889 Fax: (972) 444-8893 Acct ID: 1770 File No: C15-0812 Date Sampled: 02/12/2016 Report Date: 03/16/2016 Previously Reported: 02/22/2016 Sampled By: Perez, Jose Project: Freeport Parkway North By Order Of: Walter Location: Ramp at intersection of Freeport Parkway and Sandy Lake, Order Number: 1770 Sidewalk at Freeport Parkway and 121 Service Rd., Sampled; Northeast ramp at intersection of Freeport Parkway and Sandy Lake Number of Client: City of Coppell Specimens: 4 REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 203597 Material: Concrete Test Method: See Below _T TEST RESULTS figpirl 1`4:1 203597 Specification Strength: 3,000 psi @ 28 days Slump: 3-5 Air Content: 3-6 Date Received: 02/13/2016 Curing Method: Standard Time Sampled: 11:25 am Time Batched: 10:23 am Temp.: Ambient: 61°F Mix: 64°F CONFORMS Slump: 4.25 Inches Transported By: LMC Air Content: 3.7% Source/Sampled At: Truck I Center Mix Code: 1261 Plant: 952 Truck/Ticket No: 5023 / 62992666 Quantity Represented: 9.5 cu. yds. at 9.5 cu. yds. placed of a 38.0 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Orig: City of Coppell (Coppell, TX) Attn: Mr, Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C, Kakara, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED. AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (int) (Ibs) Break Type Loc (PSI) (PSI) By Comments A 02/19/16 :7 6.00 28.27 73,380 Type 2 Lab 2,600 JR B 02/19/16 : 7 6.00 28.27 75,755 Type 2 Lab 2,680 2,640 JR C 03/11/16 : 28 6.00 28.27 102,090 Type 1 Lab 3,610 JR D 03/11/16: 28 6.00 28.27 110,040 Type 1 Lab 3,890 3,750 JR Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 3,000 psi @ 28 days Slump: 3-5 Air Content: 3-6 Date Received: 02/13/2016 Curing Method: Standard Time Sampled: 11:25 am Time Batched: 10:23 am Temp.: Ambient: 61°F Mix: 64°F CONFORMS Slump: 4.25 Inches Transported By: LMC Air Content: 3.7% Source/Sampled At: Truck I Center Mix Code: 1261 Plant: 952 Truck/Ticket No: 5023 / 62992666 Quantity Represented: 9.5 cu. yds. at 9.5 cu. yds. placed of a 38.0 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Orig: City of Coppell (Coppell, TX) Attn: Mr, Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C, Kakara, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED. AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. ' RLLlfil'ICE kCtEOTECFIIYICFIL .wour-- Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C15-0812 Date Sampled: 02/15/2016 Report Date: 03/16/2016 Previously Reported: 02/23/2016 Sampled By: Perez, Jose Project: Freeport Parkway North By Order Of: Walter Location: Retaining Wall Footings; Sampled Retaining Wall #3 Footings at Order Number: 1770 Type 3 5ft North from South End 6.00 28.27 99,140 Type 3 Number of 6.00 28.27 City of Coppell Specimens: 4 _Client: REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 203599 Material: Concrete Test Method: See Below TEST RESULTS Report No: 203599 Page 1 of 1 Spec Age Tested Nbr (date : days) A 02/22/16:7 B 02/22/16:7 C 03/14/16:28 D 03/14/16:28 Maximum Diameter Area Load Strength Cure (in) (int) (Ibs) Break Type Loc 6.00 28.27 98,865 Type 3 Lab 6.00 28.27 99,140 Type 3 Lab 6.00 28.27 135,415 Type 1 Lab 6.00 28.27 138,435 'f"ype:1 Lab Type 1 Type 2 Type 3 Specification Strength: 3,600 psi @ 28 days Slump: 3-5 Air Content: 3-6 Date Received: 02/16/2016 Curing Method: Standard Time Sampled: 1:05 pm Time Batched: 12:19 pm Temp.: Ambient: 71'F Mix: 67°F Compressive Average Strength Strength Tested (PSI) (PSI) By Comments 3,500 JR 3,510 3,500 JR 4,790 JR 4 900 4 840 JR Type 4 Type 5 CONFORMS Slump: 4.0 Inches Air Content: 3.6% Mix Code: 1701 Type 6 Transported By: LMC Source/Sampled At: Truck / Center Plant: 952 Truck/Ticket No: 9131 / 62992761 Quantity Represented: 9.5 cu. yds. at 9.5 cu. yds. placed of a 24 cu. yd. total placement Remarks: Test Method (As Applicable): C1064 and C138e Compressive strength testmarks, concrete was ) pe ASTMed and tC39ed n Air Content was paccordance with er AS1143, Unless noted in C231 and cylinders were not capped per ASTM C617. Orig: City of Coppell (Coppell, TX) Attn: Mr Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S)TESTEDAND)OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR 170 THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRorwc ) WITHOUT WRITTEN PERMISSION.