ST0502A- LR160316 (4)ALLlfil'ICE G GEOTKiif11Cf1L _QiOUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C15-0812 Date Sampled: 02/17/2016 Report Date: 03/16/2016 Previously Reported: 02/25/2016 Sampled By: Maumalanga, John Project: Freeport Parkway North By Order Of: Walter Location: Footing on retaining wall panel 7 at Station 2+08 to 2+36.06, Order Number: 1770 Sampled; Station 2+08 Number of Client: City of Coppell Specimens: 4 REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 203603 Material: Concrete Test Method: See Below TEST RESULTS Report No: 203603 Page 1 of 1 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (int) (Ibs) Break Type Loc (PSI) (PSI) By Comments A 02/24/16: 7 6.00 28.27 114,640 Type 4 Lab 4,050 JR B 02/24/16 : 7 6.00 28.27 117,985 Type 4 Lab 4,170 4,110 JR C 03/16/16 : 28 6.00 28.27 131,890 Type 1 Lab 4,660 JR D 03/16/16: 28 6.00 28.27 136,005 Type 1 Lab 4,810 4,740 JR /11711]1Iml �� l� R- Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification CONFORMS Strength: 3,600 psi @ 28 days Slump: 4-6 Slump: 4.0 Inches Transported By: LMC Air Content: 3-6 Air Content: 4.0% Source/Sampled At: Truck / Center Mix Code: 1701 Plant: 955 8 Date Received: 02/18/2016 Truck/Ticket No. 5028 16440036 Curing Method: Standard Time Sampled: 1:50 pm Time Batched: 12:33 pm Temp.: Ambient: 70°F Mix: 73°F Unit Weight: 140.4 #/cu ft Quantity Represented: 9.5 cu. yds. at 9.5 cu. yds. placed of a 19.0 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Orig: City of Coppell (Coppell, TX) Attn: Mr, Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED, THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION