ST0502A- LR160324fiLLIAI'ICE GEOTKHf11CFlL Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C15-0812 Date Sampled: 02/24/2016 Report Date: 03/24/2016 Previously Reported: 03/03/2016 Sampled By: Maumalanga, John Project: Freeport Parkway North By Order Of: Walter Location: Piers for light poles (8) on Freeport Parkway north, Sampled; Order Number: 1770 Station 27+40 Number of Client: City of Coppell Specimens: 4 REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 204323 Material: Concrete Test Method: See Below Spec Age Tested Nbr (date : days) A 03/02/16:7 B 03/02/16 ; 7 C 03/23/16:28 D 03/23/16 ; 28 TEST RESULTS Report No: 204323 Page 1 of 1 Specification Strength: 4,000 psi @ 28 days Slump: 3-5 Air Content: 0-3 Date Received: 02/25/2016 Curing Method: Standard Time Sampled: 2:00 pm Time Batched: 12:58 pm Temp.: Ambient: 60°F Mix: 65°F Cure Loc Lab Lab Lab Lab Compressive Average Maximum Strength Diameter Area Load (PSI) (in) (int) (lbs) Break Type 6.00 28.27 116,260 Type 4 6.00 28.27 118,955 Type 4 6.00 28.27 163,985 Type 3 6.00 28.27 165,780 Type 3 Type 1 Type 2 Type 2 Specification Strength: 4,000 psi @ 28 days Slump: 3-5 Air Content: 0-3 Date Received: 02/25/2016 Curing Method: Standard Time Sampled: 2:00 pm Time Batched: 12:58 pm Temp.: Ambient: 60°F Mix: 65°F Cure Loc Lab Lab Lab Lab Compressive Average Strength Strength Tested (PSI) (PSI) By Comments 4,110 JR 4,210 4,160 JR 5,800 JR 5.860 5,830 JR Type 4 Type 5 CONFORMS Slump: 4.5 Inches Air Content: 2.0% Mix Code: 1701 l Type 6 Transported By: LMC Source/Sampled At: Truck / Center Plant: 961 Truck/Ticket No: 1422 / 63711590 Quantity Represented: 9.5 cu. yds. at 9.5 cu. yds. placed of a 9.5 cu. yd, total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C1064 and C138. Compressive strength test per ASTM C39, Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Orig: City of Coppell (Coppell, TX) Attn: Mr. Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C, Kakara, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED, THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION