ST0502B- LR160421 (3)ALLIWYCE (3EQTKHI'iICflL UROUP Consulting Engineering * Geotechnical Engineering " Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C15-0812 Date Sampled: 03/23/2016 Report Date: 04/21/2016 Previously Reported: 04/01/2016 Sampled By: Avila, Eli Project: Freeport Parkway North By Order Of: Walter Location: Freeport Parkway monumental footing Order Number: 1770 Number of Client: City of Coppell Specimens: 4 REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 206338 Material: Concrete Test Method: See Below TEST RESULTS Report No: 206338 Page 1 of 1 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength (PSI) Strength Tested (PSI) By Nbr (date : days) (in) (int) (Ibs) Break Type Loc Comments A 03/30/16 : 7 6.00 28.27 84,820 Type 3 Lab 3,000 MM B 03/30/16: 7 6.00 28.27 82,005 Type 3 Lab 2,900 2,950 MM C 04/20/16: 28 6.00 28.27 123,340 Type 3 Lab 4,360 MM D 04/20/16 : 28 6.00 28.27/ 126,055 1 4,460 Lab 4,460 4,4101 MM IlType Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 3,000 psi @ 28 days Slump: 3-5 Air Content: 0.5-2.5 Date Received: 03/24/2016 Curing Method: Standard Time Sampled: 2:30 pm Time Batched: 1:12 pm Temp.: Ambient: 82°F Mix: 70°F CONFORMS Slump: 3.0 Inches Transported By: LMC Air Content: 2.3% Source/Sampled At: Truck / Center Mix Code: 1261 Plant: 952 Truck/Ticket No: 5023 / 62994243 Quantity Represented: 9 5 cu. yds. at 9 5 cu. yds, placed of a 9.5 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C1064 and C138. Compressive strength test per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Ong: City of Coppell (Coppell, TX) Attn: Mr. Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, SET, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION � ALLifil'ICE GEOTECFII'llCfiL UROUr Consulting Engineering " Geotechnical Engineering " Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C15-0812 Date Sampled: 03/22/2016 Report Date: 04/20/2016 Previously Reported: 04/20/2016 Sampled By: Himel, Travis Project: Freeport Parkway North By Order Of: Walter Location: Median at centerline of Freeport Parkway at Station 13+00 to Order Number: 1770 16+00, Sampled; Station 13+15 Number of Client: City of Coppell Specimens: 5 _ REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 206163 Material: Concrete Test Method: See Below TEST RESULTS Report No: 206163 Field Number: 04212016 Page 1 of 1 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength (lbs) Loc (PSI) Strength Tested (PSI) By Comments Nbr (date : days) (in) (int) Break Type A 03/29/16: 7 4.00 12.57 53,900 Type 3 Lab 4,290 MM B 03/29/16 : 7 4.00 12.57 51,670 Type 3 Lab 4,110 4,200 MM C 04/19/16: 28 4.00 12.57 69,830 Type 3 Lab 5,560 MM D 04/19/16: 28 4.00 12.57 71,455 Type 3 Lab 5,690 MM E 04/19/16: 28 4.00 12.57 70,595 Type 3 Lab 5,620 5,62_0 MM Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 CONFORMS Specification Strength: 3,000 psi @ 28 days Slump: 3-5 Slump: 4.75 Inches Transported By: LMC Air Content: 3-6 Air Content: 3.6% Source/Sampled At: Truck/ Center Mix Code: 1261 Plant: 956 Date Received: 03/23/2016 TruckMcket No: 7060 / 63099616 Curing Method: Standard Time Sampled: 11:45 am Time Batched: 11:06 am Temp.: Ambient: 66°F Mix: 69°F Unit Weight: 148.2 #/cu ft Quantity Represented: 9,5 cu, yds. at 9.5 cu. yds. placed of a 19 cu, yd. total placement Remarks: Test Method (As Applicable): Unless noted in remarks, concrete was C1064 and C138. Compressive strength test) testeded and n accordance with ASTM 1 143, per ASTM C39. Air Content was per ASTM C231 and cylinders were not capped per ASTM C617. Orig: City of Coppell (Coppell, TX) Attn: Mr Rick O'Dell (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, SEPT, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTEDANDWOR ORSERVEDANDARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALiTY:ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE HEPRODUCED wITHOUT WRITTEN PERMISSION.