Fountain Park 1-LR 931028October 28, 1993 TEXAS INDUSTRIES, INC. 7610 STEMMONS FREEWAY · DALLAS, TEXAS 75247 · (214)647-6700 Austin Bridge & Road 11143 Goodnight Lane Dallas, Tx 75229 Attention Mr. Mike Ducote' RE: Fountain Park 8274 Gentlemen: The attached concrete mix design utilizing the appropriate ASTM C-33 or ASTM C-330 aggregate is proposed for use on the above referenced project for ready mix concrete to be furnished by TXI. To ensure that the correct mix is delivered to your project, please order by the mix design number which appears in the upper left hand corner of the mix design. Texas Industries certifies that the above mix design, when ordered by specified design identity, will meet or exceed the ~ndicated design strength at a designated age when tested in accordance with the applicable and current ASTM Standards C 31, C 39, C 78, C 172, C 293, applicable provisions of C 94, and evaluated in accordance with applicable provisions of the ACI 318 Building Code. TXI would like to be included on your mailing list to receive all test reports. ASTM C 94-86a Section 14.4 entitles a manufacturer to receive copies of all test reports when strength of concrete is used as a basis for acceptance. Contact us if you have any questions or require any additional information. Please notify TXI of approval of the proposed mix design prior to its use. To ensure that the proper mix design is ordered, please send a copy of this letter, after approval, to the above referenced project to be used by the person ordering the concrete for this job. Sincerely, TEXAS INDUSTRIES, INC. Dana L. Link Customer Service Representative MIX # 8274 6.00SK ADMIX/AEA 1"CS 4000 PSI @ 28 Days AS REQUIRED Maximum Coarse Aggregate Size: ASTM C 33 1''- #4 Crushed Stone Maximum Water/Cement Ratio: 5.33 gal/sk .472 lb/lb Minimum Cement Content per Cubic Yard: 6.00 sacks Maximum Placement Slump: 5.0 inches Admixture ASTM C-494: Type A or D Air Entraining Agent ASTM C-260: 3% - 6% MATERIAL QUANTITIES PER i CUBIC YARD AT S.S.D. 564 lbs. or 6.00 sacks ASTM C 150 Type I Cement 1840 lbs. ASTM C 33 1"- #4 Crushed Stone 1273 lbs. ASTM C 33 Concrete Sand 267 lbs. or 32.0 gallons of Water 2.0 to 4.0 oz/cwt of ASTM C-494 Type A Specified Air Content: 3% - 6% Placement Slump: 4.0 + or - i inches PUMPING RECOMMENDATIONS 1. 5" minimum diameter lines with no reduction to smaller lines. 2. Keep rubber hose to absolute minimum length and plan pipe with as few go degree angles as possible. 3. Slumps and test cylinders should be taken @ discharge end of hose for strength guarantee to be valid. 4. To prime pump lines, a minimum of 8.0 sack grout should be used for lubrication. In the case of strength concrete, equivalent strength grout should be used if the grout remains in the placement. 5. Pump mixes are based on minimum cement content pumped at ground level. As pump line increases in length or height and/or layout configuration changes, additional cement may be required to assure strength and pumpability at additional cost to the contractor. We are enclosing all available back up data for the above referenced mix design. If the strength information is not available or is not sufficient, conformation cylinders may have to be made by your testing laboratory. Date: 10/28/93 TEXAS INDUSTRIES, INC. CONCRETE DESIGN EVALUATION Statistics Compiled From Independent Laboratory Test Specimens ** Mix No. K8274 Strength 4000 psi ~ 28 Days 28 Day Test Data Page: I Test Plant No. Date No. 1 02/24/93 47 2 02/26/93 47 3 03/08/93 31 4 03/16/93 31 5 03/25/93 31 6 03/26/93 31 7 03/29/93 31 8 03/30/93 31 9 03/31/93 31 10 04/01/93 31 11 04/02/93 31 12 04/05/93 31 13 04/21/93 31 14 04/21/93 31 15 04/26/93 18 16 04/27/93 18 17 04/28/93 18 18 07/23/93 32 19 07/26/93 32 20 07/26/93 32 *** Averages Temperature Placement Percent Amb Con Slump of Air ....... 28 Day ....... Cum Moving PSI 1 PSI 2 PSI Avg Avg Avg of 3 Range 66 72 4.6 4.3 N/A 65 5.2 4.2 5390 5590 5490 5490 5490 200 N/A 63 4.2 3.8 5090 5040 5065 5278 5278 50 62 70 5.5 3.6 4760 4660 4710 5088 5088 100 59 62 5.0 4.0 4570 4460 4515 4945 4763 110 77 70 5.7 N/A 5300 5890 5595 5075 4940 590 75 7D 5.0 N/A 6010 5940 5975 5225 5362 70 75 70 5.5 N/A 4740 4920 4830 5169 5467 180 70 75 7.0 N/A 5450 5660 5555 5217 5453 21D 65 65 6.0 N/A 5730 5840 5785 5280 5390 110 60 65 4.5 N/A 4410 4820 4615 5214 5318 410 58 69 3.5 N/A 5040 4810 4925 5187 5108 230 60 65 4.5 N/A 5620 5760 5690 5229 5077 140 45 60 4.5 4.0 5230 4850 5040 5215 5218 380 48 62 5.5 4.0 4950 4880 4915 5193 5215 70 81 80 3.0 N/A 4560 4390 4475 5145 4810 170 80 85 3.0 4.8 4970 4700 4835 5126 4742 270 74 75 3.0 N/A 4650 4520 4585 5094 4632 130 N/A 89 2.2 5.0 5450 5240 5345 5108 4922 210 N/A 89 3.5 4.5 4790 5090 4940 5099 4957 300 N/A 94 4.7 4.8 4410 4640 4525 5071 4937 230 COMMENTARY OF STATISTICAL EVALUATION OF CONCRETE DESIGN RESULTS Mix No. K8274 Strength 4000 psi @ 28 Days Paragraph 5.5 of ACI 318-89 provides that as data becomes available during construction, the amount by which (f'cr) must exceed the specified value of (f'c) may be reduced, provided: (a) 30 or more test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.1, or (b) 15 to 29 test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.2. The required average compressive strength has been calculated using a standard deviation calculated in accordance with ACI 318-89 Section 5.3.1.1 or Section 5.3.1.2 and is the larger value of these calculations f' = f' + 1.34(SD) cr c = 4000 + 1.34(00507) : 4679 f' : f' + 2.33(SD) - 500 cr c 4000 + 2.33(00507) - 500 4681 The standard deviation has been modified according to ACI 318 Table 5.3.1.2 SUMMARY OF STATISTICAL ANALYSIS 28 Day Test Data Number of Tests .......................... 20 Maximum Value ............................ 5975 psi Minimum Value ............................ 4475 psi Range .................................... 1500 psi Average Strength ......................... 5071 psi Standard Deviation ....................... 507 psi Required Average Strength to satisfy minimum probability conditions of ACI 318-89 Section 5.3.2.1 ............... 4681 psi Design excess beyond code requirements.. 390 psi