Loading...
DCT Fellowship- LR160301 2424 STUTZ DR.  SUITE 400  DALLAS, TX 75235  TEL [214] 350 5600  FAX [214] 350 0019 CONCRETE CYLINDER TEST REPORT DCT Freeport West Bethel Road and Creekview Drive Coppell, Texas REPORTED TO: DCT Industrial Trust 5430 LBJ Freeway, Suite 1030 Dallas, Texas 75240 ATTN: Mr. Joe Williams REPORT NO. 29 REG PROJECT NO. 20922 SAMPLE DATE: 03-01-16 TECHNICIAN: C. Winchester PAGE: 1 of 2 CONTRACTOR: FCL Builders Texas Location of Sample Set Number Location Quantity Represented (c.y.) 1 Slab: J.4-2.9 38/494 2 Slab: H-2.1 104/494 3 Slab: F.3-2.8 209/494 4 Slab: D.5-2.9 313.5/494 5 Slab: B.9-2.7 408.5/494 Design Information Source of Concrete Mix Identification Specified Strength (psi) LMC 1600 4000 Test Results Set No. Cylinder ID Date Tested Age @ Test Total Load (lbs.) Compressive Strength (psi) Average Strength (psi) 1 5592 03-08-16 7 48010 3820 5592 03-29-16 28 67070 5340 5592 03-29-16 28 62660 4990 5592 03-29-16 28 66120 5260 5200 5592 Hold H 2 5593 03-08-16 7 49420 3930 5593 03-29-16 28 64750 5150 5593 03-29-16 28 60190 4790 5593 03-29-16 28 61180 4870 4940 5593 Hold H 3 5594 03-08-16 7 47170 3750 5594 03-29-16 28 60140 4790 5594 03-29-16 28 62590 4980 5594 03-29-16 28 65120 5180 4980 5594 Hold H REPORT NO. 29 REG PROJECT NO. 20922 SAMPLE DATE: 03-01-16 PAGE: 2 of 2 Test Results Set No. Cylinder ID Date Tested Age @ Test Total Load (lbs.) Compressive Strength (psi) Average Strength (psi) 4 5595 03-08-16 7 51380 4090 5595 03-29-16 28 66620 5300 5595 03-29-16 28 72390 5760 5595 03-29-16 28 58470 4650 5240 5595 Hold H 5 5596 03-08-16 7 48220 3840 5596 03-29-16 28 62690 4990 5596 03-29-16 28 69200 5510 5596 03-29-16 28 66750 5310 5270 5596 Hold H Cylinder Data Set No. Cylinder ID Slump (inches) Time of Sample Air Temp. (°F) Concrete Temp. (°F) Air Entrainment (%) Unit Weight (lbs/ft3) Ticket Number 1 5592 4.0 4:30 AM 64 68 1.4 148.0 63099035 2 5593 4.75 5:15 AM 65 68 1.5 147.2 63099041 3 5594 4.75 6:25 AM 65 68 1.5 147.2 63099053 4 5595 4.75 7:50 AM 64 70 1.3 147.2 63099064 5 5596 5.0 8:50 AM 65 67 1.4 147.2 63099074 Note: (1) Concrete was sampled in accordance with ASTM C-31 (2) Concrete cylinders were tested in accordance with ASTM C-39 E-Mail Distribution: (1) DCT Industrial Trust/ Mr. Joe Williams (1) DCT Industrial Trust/ Mr. Sophia Montemayor (1) FCL Builders Texas/Mr. Drew Hanlon (1) Pross Design Group/Mr. Bobby Pross (1) City of Coppell/Mr. Marcus Marion (1) Pacheco Koch/Mr. Clayton Strolle (1) McHale Engineering/Mr. Matt Skaggs Submitted by: REED ENGINEERING GROUP, LTD. Registration Number F-3114 Cary Tipps Project Manager, CMT CT/cn