Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
DCT Fellowship- LR160305
2424 STUTZ DR. SUITE 400 DALLAS, TX 75235 TEL [214] 350 5600 FAX [214] 350 0019 CONCRETE CYLINDER TEST REPORT DCT Freeport West Bethel Road and Creekview Drive Coppell, Texas REPORTED TO: DCT Industrial Trust 5430 LBJ Freeway, Suite 1030 Dallas, Texas 75240 ATTN: Mr. Joe Williams REPORT NO. 40 REG PROJECT NO. 20922 SAMPLE DATE: 03-05-16 TECHNICIAN: I. Juarez PAGE: 1 of 2 CONTRACTOR: FCL Builders Texas Location of Sample Set Number Location Quantity Represented (c.y.) 1 Slab: A.5-4.2 76/427 2 Slab: B.3-4.5 161.5/427 3 Slab: E-4.2 266/427 4 Slab: H-4.5 323/427 Design Information Source of Concrete Mix Identification Specified Strength (psi) LMC 1600 4000 Test Results Set No. Cylinder ID Date Tested Age @ Test Total Load (lbs.) Compressive Strength (psi) Average Strength (psi) 1 5888 03-12-16 7 41450 3300 5888 04-02-16 28 61100 4860 5888 04-02-16 28 53280 4240 5888 04-02-16 28 64860 5160 4750 5888 Hold H 2 5889 03-12-16 7 49480 3940 5889 04-02-16 28 58270 4640 5889 04-02-16 28 61620 4900 5889 04-02-16 28 60940 4850 4800 5889 Hold H 3 5890 03-12-16 7 50860 4050 5890 04-02-16 28 66270 5270 5890 04-02-16 28 64480 5130 5890 04-02-16 28 68620 5460 5290 5890 Hold H REPORT NO. 40 REG PROJECT NO. 20922 SAMPLE DATE: 03-05-16 PAGE: 2 of 2 Test Results Set No. Cylinder ID Date Tested Age @ Test Total Load (lbs.) Compressive Strength (psi) Average Strength (psi) 4 5891 03-12-16 7 50710 4030 5891 04-02-16 28 63080 5020 5891 04-02-16 28 65780 5240 5891 04-02-16 28 60200 4790 5020 5891 Hold H Cylinder Data Set No. Cylinder ID Slump (inches) Time of Sample Air Temp. (°F) Concrete Temp. (°F) Air Entrainment (%) Unit Weight (lbs/ft3) Ticket Number 1 5888 5.0 5:04 AM 60 63 1.0 149.4 63099322 2 5889 4.5 6:00 AM 60 63 1.0 149.4 63099331 3 5890 5.0 7:28 AM 62 63 0.5 149.7 63099342 4 5891 4.0 8:16 AM 61 63 1.0 149.6 63099348 Note: (1) Concrete was sampled in accordance with ASTM C-31 (2) Concrete cylinders were tested in accordance with ASTM C-39 E-Mail Distribution: (1) DCT Industrial Trust/ Mr. Joe Williams (1) DCT Industrial Trust/ Mr. Sophia Montemayor (1) FCL Builders Texas/Mr. Drew Hanlon (1) Pross Design Group/Mr. Bobby Pross (1) City of Coppell/Mr. Marcus Marion (1) Pacheco Koch/Mr. Clayton Strolle (1) McHale Engineering/Mr. Matt Skaggs (1) FCL Builders Texas/ Mr. Ethan McIntosh Submitted by: REED ENGINEERING GROUP, LTD. Registration Number F-3114 Cary Tipps Project Manager, CMT CT/cn