Loading...
DCT Fellowship- LR160329 (5) 2424 STUTZ DR.  SUITE 400  DALLAS, TX 75235  TEL [214] 350 5600  FAX [214] 350 0019 CONCRETE CYLINDER TEST REPORT DCT Freeport West Bethel Road and Creekview Drive Coppell, Texas REPORTED TO: DCT Industrial Trust 5430 LBJ Freeway, Suite 1030 Dallas, Texas 75240 ATTN: Mr. Joe Williams REPORT NO. 55 REG PROJECT NO. 20922 SAMPLE DATE: 03-29-16 TECHNICIAN: K. Wicks PAGE: 1 of 2 CONTRACTOR: FCL Builders Texas Location of Sample Set Number Location Quantity Represented (c.y.) 1 Paving: 32’N, 98’W from NE approach 28.5/798 2 Paving: 108’N, 336’W from NE approach 161.5/798 3 Paving: 144’N, 423’W from NE approach 266/798 4 Paving: 97’N, 503’W from NE approach 350/798 5 Paving: 55’N, 592’W from NE approach 437/798 6 Paving: 112’N, 689’W from NE approach 560.5/798 Design Information Source of Concrete Mix Identification Specified Strength (psi) LMC 1375 3500 Test Results Set No. Cylinder ID Date Tested Age @ Test Total Load (lbs.) Compressive Strength (psi) Average Strength (psi) 1 6461 04-05-16 7 40720 3240 6461 04-26-16 28 6461 04-26-16 28 6461 04-26-16 28 6461 Hold H 2 6462 04-05-16 7 50100 3990 6462 04-26-16 28 6462 04-26-16 28 6462 04-26-16 28 6462 Hold H 3 6463 04-05-16 7 31080 2470 6463 04-26-16 28 6463 04-26-16 28 6463 04-26-16 28 6463 Hold H REPORT NO. 55 REG PROJECT NO. 20922 SAMPLE DATE: 03-29-16 PAGE: 2 of 2 Test Results Set No. Cylinder ID Date Tested Age @ Test Total Load (lbs.) Compressive Strength (psi) Average Strength (psi) 4 6464 04-05-16 7 39380 3130 6464 04-26-16 28 6464 04-26-16 28 6464 04-26-16 28 6464 Hold H 5 6465 04-05-16 7 41800 3330 6465 04-26-16 28 6465 04-26-16 28 6465 04-26-16 28 6465 Hold H 6 6466 04-05-16 7 42320 3370 6466 04-26-16 28 6466 04-26-16 28 6466 04-26-16 28 6466 Hold H Cylinder Data Set No. Cylinder ID Slump (inches) Time of Sample Air Temp. (°F) Concrete Temp. (°F) Air Entrainment (%) Unit Weight (lbs/ft3) Ticket Number 1 6461 5.0 2:45 AM 59 66 4.7 140.0 64403018 2 6462 4.0 3:50 AM 59 66 4.4 144.8 64403036 3 6463 8.0 4:40 AM 59 60 5.2 143.6 63099858 4 6464 6.5 5:45 AM 58 66 5.7 141.2 N/A 5 6465 6.5 6:25 AM 58 66 5.8 140.8 63099868 6 6466 5.0 8:15 AM 59 66 3.1 143.6 62994481 Note: (1) Concrete was sampled in accordance with ASTM C-31 (2) Concrete cylinders were tested in accordance with ASTM C-39 E-Mail Distribution: (1) DCT Industrial Trust/ Mr. Joe Williams (1) DCT Industrial Trust/ Mr. Sophia Montemayor (1) FCL Builders Texas/Mr. Drew Hanlon (1) Pross Design Group/Mr. Bobby Pross (1) City of Coppell/Mr. Marcus Marion (1) Pacheco Koch/Mr. Clayton Strolle (1) McHale Engineering/Mr. Matt Skaggs (1) FCL Builders Texas/ Mr. Ethan McIntosh Submitted by: REED ENGINEERING GROUP, LTD. Registration Number F-3114 Cary Tipps Project Manager, CMT CT/cn