Loading...
WA9301-SP 971209Date: December 9, 1997 City of Dallas Submittal No. 16500-01 To~ Bar Constructors, Inc. P.O. Box 10 Lancaster, Texas 75146-0010 Attention: Ms. Lucy Garcia Coppell 2 Metering Station Contract No. 94-81 Gentlemen: We are returning the following submittal data: IDENTIFICATION DESCRIPTION Submittal 16500 METAULUX & LUMARK indoor and outdoor lights DISPOSITION 9 3 X Distribution: Design Engineer - 1 Project Manager - 5 (Pile- 1), (Pield- 1), (Coppen - 1), (Pumping - I) Water Utilities Department Design Se~ces ® 320 E. Jefferson, Rm 213, Dallas, Texas 75203,214 / 948-4576, FAX 214 / 948-4599 A city utility providing regional water and wastewater se~ces vital to public health and safety. CITY OF DALLAS, TEXAS PROJECT No. 94-81 COPPELL 2 METERING STATION LIGHTING AND SWITCHGEAR PRODUCT DATA SUBMITTAL SPECIFICATION SECTIONS 16182, 16400, 16471,~~ CIRCUIT BREAKERS, SERVICE AND DISTRIBUTION, PANELBOARDS AN "~;~ BAR CONSTRUCTORS, INC. GENERAL CONTRACTOR ACME ELECTRIC COMPANY FORT WORTH, TEXAS JOB #2323 REVIEWED BAR CONST:~eU~/~)r~S, INC. ~ C~stm~, I~. reDrE senIs t~t MW dle~ined and ~dfie~ all ~effi ~Mtmct~n criteria, mateda& c~talog ~mMm, and simb~ date, a ~a that we ha~ c~ed wiffi t~ mqui~n~n~ of ~e W~ a~ ~e Contact Docu~ nents. Industrial,Vapodi/e VTllndustrial/Vaportite · Equipped With Energy Saving Ballasts/Complies With FederaJ Energy Efficiency Standards ~) · Reinforced Fiberglass Housing · High Impact Acryfic/DR Diffuser Matedal · Continuous Po/yurethane Gasketing Formed To Housing Provides A Seamless Seal · Waterrite Hubs Standard At Each End Accepts 1/2" Conduit · Optional Top Only Hub Entry Or Combination Top And End Hub Entry Available · Die Formed Steel Mounting Brackets (Standard) With Each Fixture · Baked White Enamel Finish Uner/High Refiectance · No Holes Required For Surface/Chain Mounting · Unitized Internal/External Brass Mounting Stud For Structural Integrity And Continuity Of Ground · U.L. Usted For Wet Locations (Standard) · Available in 2', 4' Or 8' Lengths · National Sanitation Foundation Usted · USDA Approved Design Features Construction Rberglass housing is reinforced pdyester and serf-extinguishing (ASTM D635-74} plastic of a permanent peal gray color. Top of housing has five embossmerits (2' unit}, nine embossrnents (4' unit), and thirteen embos.m'rels, (8' unit) providing mounting flexibility on uneven surfaces. A waterrite hub for 1/2' conduit entry is provided at each end of housing (standard} for continuous feed. Polyurethane gasketing is formed to the housing providing a continuous seamless seaJ for the diffuser. Four sturdy cam latches (2' unit), six (4' unit), and twelve (8' tandem unit) clamp diffuser tightly for a positive seal between housing, gasket and diffuser. 2', 4' or 8' - l or 2 Lamp R Electrical Unit has full metal liner (channel) secured by brass internal/external mounting studs for positive grounding, maximum protection and rigidity. Ballasts ere CBM/ETL Class "P' certified suitable to plus 50°. (Cold temperature ballasts are available suitable to 0°F, on special order) Pressure lock lampholders. Electrical components and fixtures UL listed and IBEW labeled, (See note 2) Shielding · DR" - Clear low brightness pattern acryfic with 15% high impact additive. "DR-100" -Clear low brightness pettem acrylic with 100% high impact additive. Example'. VT2-240DR-100 · LEX"- High impact clear low brightness pattern polycarbonate, LEXAN Example: VT2-240LEX. 4' or 8' - l or 2 Lamp SI 126 MounUng Brackets (Furnished) {Two per 2' end 4' Unit, Four per 8' Unit) Optional Chain Hanging Kit (VT2-CHAIN/SET-U) (Includes 4 chains, 4 large S- Hooks and 4 small S-Hcoks Order One (1) Kit for each 2' or 4' Fixture. Two (2) Kits Recommended Fo~ 8' Fixture Installation t/ Construction Notos (1) Standard Ballast (Non-LE3) METALUX 4' or8' - I or2Larnpl-IC Catalog Nominal Number Lamps Ballast Size (ft.) Wt. VT2-120 DR-WL~ 1F20 Rapid Start 2 8 VT2-220 DR-WM 1F20 Rapid Stad 2 8 VT2-1SX40 DR-WL 1BX40 Rapid Start 4 8 VT2-1BXSO DR-WL 1BX50 Rapid Start 4 8 VT2-140 DR-WL 1F40 Rapid Start 4 16 8TVT2-140 DR-WL 1F40 Rapid Start 4 31 V1'2-240 DR-WL 2F40 Rapid Start 4 16 8TVT2-240 DR-WL 2F40 Rapid Start 4 31 v'r2-148 D!I-WL' 1F48 Slimline 4 16 VT2-196 DR-WU 1 F96 Slimline 8 35 VT2-248 DR-WL~ 2F48 Slimline 4 16 VT2-296 DR-WL 2F96 SlimPine 8 35 VT2-148HO DR-WL~ 1F48 600MA 4 20 VT2-248HO DR-WL~ 2F96 800MA 4 20 VT2-196HO DR-WL~ 2F48 800MA 8 20 VT2-296HO DR-WL' 2F96 800MA 8 20 97-13/16 For detailed Fudure Dimensional Data refer to Channel Diagram number on page 231. Dimensions (inJ Length WIdth Height 25-13/16 6-5/8 5 25-13/16 6-5/8 5 49-13/16 6-5/8 5 49-13/16 6-5/8 5 49-13/16 6-5/8 5 49-13/16 6-5/8 5-7/8 49-13/16 6~5/8 5-7/8 49-13/16 6-5/8 5-7/8 49-13/16 6-5/8' 5-7/8 97-13/16 6-5/8 5-7/8 49-13/16 6-5/8 5-7/8 97-13/16 6-5/8 5-7/8 49-13/16 6-5/8 5-7/8 49-13/16 6-5/8 5-7/8 49-13/16 6-5/8 5-7/8 6 - 5/8 5 - 718 Channel Slogram* 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 photometrics VT2-240 DR-WL VT2-296 DR-WL VT2 Series h ~d,jstrial/%/aportite icients of Utilization 80% 70% 10 60 30 10 70 50 30 10 85858585 82828282 76 71 68 64 73 69 66 63 68 61 56 51 86 60 55 50 62 54 47 42 59 52 46 41 56474035 54"464035 52 42 35 30 50 41 34 30 48 38 31 26 46 37 30 26 44 34 27 23 42 33 27 23 41 31 25 20 40 30 24 20 38 28 22 18 37 28 22 18 36 26 20 16 35 25 20 16 20% 50% 30% 10% O% 50 30 10 50 50 10 50 30 10 0 77 77 77 73 73 73 68 68 68 66 65 62 60 61 59 57 58 56 54 52 56 52 48 53 49 46 50 47 44 42 49 44 40 46 42 38 44 40 37 35 43 38 34 41 36 33 39 35'31 30 39 33 29 37 32 28 35 30 27 25 35 29 25 33 28 24 31 27 24 22 31 26 22 30 25 21 28 24 21 19 29 23 20 27 23 19 26 22 19 17 26 21 18 25 21 17 24 20 17 15 24 19 16 23 19 16 22 18 15 14 Coefficients of Utilization pf__¢ p¢¢ 80% 70% pw 70 50 50 10 70 50 30 10 RCR 0 85858585 82828282 I 76 72 69 66 74 70 67 64 2 69 63 57 53 66 61 56 52 3 63 55 49 44 61 53 48 43 4 57 49 42 37 55 47 41 37 5 52 43 38 31 50 42 35 31 6 48 38 32 27 46 37 31 26 I 44 34 28 23 43 33 27 23 8 41 31 24 20 39 30 24 20 I 38 27 21 17 36 27 21 17 10 35 25 19 15 34 24 19 15 20% 50% 50% 10% O% 50 30 10 60 30 10 50 30 IO O 77 77 77 73 73 73 68 68 68 66 66 63 61 62 60 58 59 57 55 53 57 53 50 54 51 48 51 48 48 44 50 46 42 48 44 40 45 42 39 37 45 40 35 42 38 34 40 36 33 31 39 34 30 37 33 29 35 31 28 26 35 30 26 34 29 25 32 28 24 23 32 26 22 30 25 22 29 24 21 20 28 23 19 27 22 19 26 22 18 17 26 20 17 24 20 16 23 19 16 14 23 18 15 22 17 14 21 17 14 13 0 1166 1166 1166 1141 1155 1170 20 1100 1148 1192 30 1013 1108 1190 40 841 984 1104 50 631 814 957 60 429 640 781 70 249 481 616 80 107 346 497 90 18 210 350 100 14 125 220 110 12 86 161 ! 120 8 42 79 ~ 130 5 19 30 :140 3 8 15 150 2 3 7 160 1 2 3 170 I 1 1 180 0 0 0 Candlepower Angle Along II 4/° .l~r~BJ. EllefgySavirlgBeilast, 0 2332 2332 2332 F40T12/CW lamps rated 10 2282 2310 2339 at 4300 lumens. Spacing 20 2200 22~5 2384 criterion: (11) 1 .:29 x 30 2026 2216 2379 mounting height, (J,) 1.51 40 1682 1968 2207 x mounting height 50 1261 1627 1914 60 858 1279 1562 70 497 961 1232 80 214 692 993 90 36 420 700 100 28 250 440 110 23 171 322 For complete 120 15 84 t58 photometric report 120 10 37 59 140 6 16 30 request 150 3 6 13 VT-240OR-WL report 150 2 3 5 #M-2062. 170 2 I 2 Effidency = 72.16% 180 0 0 ~:~ F96T 12/CW lamps rated .' . at 6300 lumens. Spacing · . ..... criterion: (11) 1.29 x mounting height, ((1) 1.51 !:'i~ ~.. "'.'- ~.. x mounting height For complete photometric report request VT-296 DR report #M-3110. ' ~ ' "' :- ! Efficiency=72.16% T: 40x40 80x50 60x100 100x60 ;~ 100x100 cal VCP Percentages Height Along Height Acree~ 13,O' 11.O~ tl.0' 16.O' Zone Lunten8 46 ' 52 39 46 0-30 967 41 45 32 37 0-40 1634 38 40 26 29 0-60 2966 41 45 35 40 0-90 4189 37 40 27 20 90-180 357 0-180 4546 Zonal Lumen Summary %l,amp %FIxture 15.34 21.26 25.93 35.94 47.08 65,25 66.49 92,15 5.66 7.85 72.16 100.00 Typical VCP Percentages RN~m Height Abetg Height Size (Ft,) 13,O* 16,0' 13,0' 16,0' 40 x 40 29 34 23 28 50x50 25 28 18 22 60x100 23 25 14 16 100x60 25 29 21 24 100x100 23 25 15 17 Zonal Lumen Summary Zeete bantens %bamp .%Fixtare 0-30 1933 15,34 21.26 0-40 3267 25.93 35.94 0-60 5933 47.08 65.25 0-90 8378 66.49 92.15 90-180 714 5.66 7.85 0-180 9092 72.16 100,00 C% ( dering Inforntation Example VT2-240 DR-WL 8T Tandem (6' Length, Deep Housing) -" .=ries Number of Lamps I or 2 [Not ~nc~uded) Wattage (Length) 20-20 W (24")RS 17-17 W (24")RS* 40-40 W Biaxial (24")RS 50-50 W Biaxial (24")RS 40-40 W (24")RS 32-32 W (48")RS* * Indicates T8 Lamp(s) DR Intemal Prismatic Lens/15% DR High Impact Additive (Standard) DR-1OO 100% High Impact Additive LEX High Impact Clear Polycarbonate LEXAN Lens/Low Brightness Pattem Specifications & Dimensions subject to change without notice. High Output 800MA Voltage 120V or 277V Consult Factory LE3 Energy Saving Ballast LEOC8 Energy Saving Ballast (For T-8 Lamps EB Genedc ' ~_Electronic Ballast No. of Ballasts lor2 ~ Lamp Size 2-T12 8-T8 5- F40 Biax (FOr Specific ilecbenic Ballast 8~ecl~y Brand m.I ik~g Number) GL Single Element Fusing GM Double Element Fusing EL4, Emergency Ughting EL8 Self-Contained (indoor Use Only) RIF1 Radio Interference Suppressor TH (2) Top Waterrite Hubs T~=H (2) Top & (2) End Watertite Hubs (All Watertire Hubs have 1/2" conduit entr,/) WL Wet Location Labeled Additional Options and Accessories Available. See Options and Accessory Section Pages 207-209 I VR VandaJ Resistant DD Deep Diffused (Availab4e On 4' Fixtures, Deep Housing Standard On 8' Fixtures) Deep Diffuser (DD) Available For 4' Fixture Length To Complement Deep Diffuser Depth of 8' Fixture METALUX HA.MMER 70-400 WATT HPS/MH Area/Site AppllcaUons DImensions Ordering Information Hammer combine contemporary styling with durability and performance excellence. Superior beam utilization and smooth distribution make Hammer ideal for parking areas, access roadways and other general offstreet area/site Iightjng applications. -- lS" -- Catalog Number Logic Lamp Product Type Family HP=HPS HR=Hammer MH=Met. Hal. re=Type l R2=Type II R3=Type III AC=Area Outoff2 Note: For illustrations of options and accessories, see page 114. For more information, see the Lurnark Technical and Applications Guide. Lamp Wattage/BaN 70=70W/Mogul 100=100W/Mogul 150=150W/Mogul 175=175W/Mogul 200=200W/Mogul 250=250W/Mogul 400=-400W/Mogul 250/400=250/400W/Mogul Catalog' Lamp Lamp Net. Wt. Number lype DlstrlbutJon Watbge EPA (Lbs.) HPHR-R3-70-MT HPS Type III 70 1.58 31 HPHR-R3-1OO-MT HPS Type III 100 1.58 31 HPHR-R3-150-MT HPS Type Ill 150 1.58 33 HPHR-R3-2OO-MT HPS Type III 200 1.58 39 HPHR-R3-250-MT HPS Type III 250 1.58 39 HPHR-R3-4OO-MT HPS Type III 400 1.58 46 HPHR-R3-250/400-MT HPS Type III 250/400 1.58 46 MHHR-R3-175-MT MH Type III 175 1.58 39 MHHR-R3-250-MT MH Type III 250 1.50 39 MHHR-R3-4OO-MT MH Type Ill 400 1.58 46 MHHR-R3-250/400-MT MH Type III 250/400 1.58 46 Multi-Tap ballasts are 120/208/240/277 Volt, factory pre~wired for 277V operation. 400 watt MH area cutoff luminaire must use ED-28 lamp. Options (add a~ suffix) PER=NEMA Ph0t0c0ntr01 Receptacle Fl=Single Fuse (120 or 277) F2=Double Fuse (208, 240 or 480) Q=Quartz Standby AF=Four-stage air filter HS/HR=House side cutoff VS=Vandal shield AcHedes (order separately) OA1016=Photoelectric control, 105-285 volt NEMA type OA1027=Photoelectric control, 480 volt NEMA type OAlO28=Field-installed photocontrol receptacle, NEMA type OA1090=Adjustable slipfitter for 2 3/8" O.D. vertical tenon OA1061 =Direct mount plate for square pole OA1062=1 O" arm for square pole, .53 EPA OA1063=Direct mount plate for round pole OA1064=1 O" arm for round pole, .53 EPA OA1065=Wall mount bracket OA1066=Mast arm adapter for 2 3/8' OD. tenon Voltage 120~120V 208=208V 240=240V 277=277V 347--347V 480=480V MT=Multi-Tap ShippbO Volume 1/ctn. 1.65 cu. ft. 54 LUMARK |' Design Features Spring-loaded, die-cast latches provide entry withost tools Weather-resistant, one-piece die-cast aluminum housing finished In dark bronze polyester powder coat enamel. Hydroformed specular aluminum reflector delivers repoataMe lype I, II, III, and Area Cutoff dlstrilxjtions Die-cut, dacron-polyester gasket seals out external oontaminants Mogul-base porceleln socket for metal hallde or high-pressure sodium lamps Removable one-piece die-cast aluminum door with clear fist tempered glass lens Removable swing-down ballast assembly with quick-disconnect plug simplifies maintenance UL 1572 listed for wet locations CSA cerUfied Photometrlcs Catalog Number HPHR-R3-4OO-MT 400-Watt HPS 50,000-Lumen Clear Lamp HR-2 Catalog Number MHHR*R3-4OO-MT 400-Watt MH 34,000-Lumen Clear Lamp 5 4 3 2 I 0 I 2 3 4 5 2 ~X,~~,/~ 1 0 2 4 5 4 3 2 I 0 I 2 3 4 5 Lateral and Longitudinal Distance In Units of Mounting Helglds Footcandle Table MounUng Height A B C D E 20' 22.50 11.25 4.50 2.25 1.13 25' 14.40 7.20 2.88 1.44 0.72 30' 10.00 5.00 2.00 1.00 0.50 Lateral and Longitudinal DIstance In Units of Mounting Heights Footcandle Table Mounting Height A B C D E 20' 11.25 4.50 2.25 1.13 0.45 25' 7.20 2.88 1.44 0.72 0.29 30' 5.00 2.00 1.00 0.50 0.20 LUMARK Fluorescent Lamps T-12 Medium Bipin Nominal Length is the dimension from back of socket to back of socket. [1: Nominal Product Nom. Avg. Appro>c: Design Watts · Bulb Base 046677- Code Qty. Description (In.)(212) (202) ) (208) CRI Econ-o-watt Rapid Start Fluorescent Lamps Direct energy saving substitutes for standard lamps. 34 T-12 Med.:T;®f$$$ 244~i~ ' ~ CoolWhite, Palletjzed(214),4100K 48 20,000+(205) 2650 2300 62 Bipin ":E', S$$ 33952-3 F-40CW/RSEW UPC "30 Cool White(214)(225). 4100K 48 20,005+(205) 2650 2300 62 "E:'f$$$ 24475-6 ~F4OCWIRS/EWIALTO 30 CoolWhite(214)(225).4100K 48 20,000+(205) 2650 2300 62 · .UPC":!: :.: :..' ' S$S 28511-4 '. ~S/EW 30 Deluxe Cool White(214), 4200K 48 20,005+(205) 1925 1580 89 ~, SSS 21992-3 'HJ)DX/RSEW .. 30 Daylight Deluxe, 6505K 48 20,000 2025 1775 84 · :E;S$S 28534-6 .f_',40LW/RS/BIV~' 30 LiteWhite(214),4100K 48 20,005+(205) 2750 2400 51 .:.E','Sg$ 29502-2 !~W~RS/~'W'PLIZ' 650 Lite White, Palletized(214). 4100K48 20.000+(205) 2750 2400 51 .~.- .:~: fsss 23Tfl.-6" 't4~PtC35/RS/" '; 30" ,, ' ~; ' "' ~EW/ALTO ~"" ~"'~;.~' / '~i~.~,~:'!:" ,. :~' !, 'C:E::' ,..~SSS 2i316'5' ':F4OSF/RS/EW: 6 '.""~ :' ' · '. .'~ SSS 29471-0' '~ijWW/RS/BR/ · 650 Warm White, PaIletjzed(214). 3000K 48 2700 2350 53 Ultralume Econ-o-watt Rapid Start Lamps Combining the Finest Color Rendering with Energy Savings. Direct energy saving substitutes for standard lamps. 34 T-12 Med, (~$$$ _31532:5' .'iU/R$)Lt/;1.'.. 30: Sipin .' j®t$$S 23781-8' .~U/RS/. ,.. ' 30 -:: EW/ALT0 ~,....,. ;L®tsSs 23~62~:r-~l/~s~/~s/"..'.=.. '...'sg : .; tiN/ALTO %':i,' · ' ." {E)$$$ 31533-~' .'F40/41'U/RS~W. 30 '.!d~$$$ 23783-4. 'F-~!0/41U/RS/'..: "30 _ EW/ALTO Q~)~$$$ 31535-8 F40/5OU/RS/EW 30 ~,Q~)1'$$$ 23784-2 F40~U/RS/ 30 EW/ALT0 Econ-o-watt Preheat Fluorescent Lamps Direct energy saving substitutes for standard lamps. Bipin Preheat -- Rapid Start Fluorescent Lamps Fer the Finest Color Rendering and High Efficacy. 40 T-12 Med. Bipin 30193-71 F40CWX ~30 I Deluxe Cool White, 4200K 148 120,000+(205)1 2200 I 1800 89 $$$ - CONSIDER THE ECON-O-WA'ff F40/41U/RS/EW FOR ENERGY SAVINGS. F40DX UPC ' ' Da~ghtDelu~e(225),6500i~:.- 48 !.?"?~.~.~' 20,000 .': ..-;.;::,i' 2325.~,:".f~ 30198-6 F40N Natural, 3700K 48 20,000 2100 1870 90 ~ 27251-8 F40SPEC30 S$$ --CONSIDER THE ECON-O-WATr F40 SPEC30/RS/EVV FOR ENERGY SAVINGS. ~ S$S --Energy Saving Product ~ High Color Rendering Lamps Means This Bulb Meets US Federal Minimum Efficiency Standards ~ Exclusive Philips Product 1' New Since Last Printing This lamp features Alto technology 7O .f:. 'SSA Square Straight Aluminum Ordering Information The following example illustrates the correct way to enter an order for SSA6M30WXM2XG. The ordering designation is detailed as follows. Catalog Number Logic Shaft Well MounUng Dis. Thick- Height hie Square Straight Aluminum at hie ness {fi~-i ~ Finish S S A 6 M 30 W X Fixture Number & Access Mounting Location Arm (Oreurn Type of Arms Length Lug) M 2 X G EPA (Sq. Fixtures Net. EPA (Sq. Ft.), Located 2ft.' Lum.& Catalog' Mtg. Shaft Weight At Pole Top Above Pole Top Bracket Number Ht. (Ft.) Size (In.i (I-bs4 80 90 !00 80 90 t00 Weight ~ SSA4T08WX 8 4x4 23 26.0 20.0 15.7 20.5 15.8 12.4 100 SSA4T10WX 10 4x4 28 22.7 17.4 13.5 18.3 13.9 10.9 100 SSA4T12WX 12 4x4 32 14.6 10.8 8.0 12.4 9.2 6.8 100 SSA4T15WX 15 4x4 39 11.0 7.8 5.6 9.4 6.7 4.8 100 SSA4M15WX 15 4x4 55 13.0 9.5 7.0 11.4 8.3 6.1 100 SSAST15WX 15 5x5 52 13.8 9.9 7.2 12.1 8.7 6.3 100 SSA4T18WX 18 4x4 45 4.4 2.5 1.1 3.9 2.2 1.0 100 SSA4M 18WX 18 4x4 66 8.4 57 3.7 7.6 5.1 3.3 150 SSAST18WX 18 5x5 61 9.2 6.0 3.8 8.2 5.4 3.4 100 SSASM18WX 18 5x5 85 16.1 11.5 8.2 14.4 10.3 7.4 150 SSA4M20WX 20 4x4 72 9.0 6.0 3.9 8.0 5A 3.4 150 SSAST20WX 20 5x5 66 6.7 3.9 1.9 6.1 3.5 1.7 100 SSA5M20WX 20 5x5 94 12.8 8.7 5.8 11.6 79 5.3 150 SSA5M25WX 25 5x5 115 9.4 6.2 3.1 8.1 4.9 2.5 150 SSA6M25WX 25 6x6 140 12.4 7.6 4.2 11.4 7.0 3.9 150 SSA6M30WX 30 6x6 166 9.3 4.9 1.7 8.4 4.4 1.6 150 SSA6X30WX 30 6x6 215 15.9 10.1 6.0 14.7 ' 9.4 5.6 150 SSAgX30WX 30 6% x BX 237 22.2 14.9 9.7 20.5 13.8 9.0 150 SSA6X35WX 35 6x6 249 4.3 .... 4.1 .... 150 SSAgX35WX 35 6% x 6% 274 7.6 2.8 -- 7.2 2.7 150 1 Catalog item includes one set of anchor bolts, single nuts and (2) leveling shims. 2 All 25' and higher luminaire mounting height lighting standards have a facton/installed vibration damper. 3 The above is our standard commercial offering. Where higher EPNWind Speed capacity is required, other shaft dimensions and/or wall thicknesses are available. EP,~ based on shaft properties with wind normal to flat. EPAs calculated using bose wind velocity as indicated plus 30% gust factor. 4 EPA capacity decreases with additional luminaire weight. Consult facton/for EPA Ratings when heavier leaclings are required. Mounting Options Finishes' Data for Bases Fixed Tenons(add as suffix) B Clear Anodized Bolt Bolt Bolt Designation O.D. Length C Dark Bronze Anodize Pole Circle Proj. Dim. Handl Number (In.) (in.) D Black Anodize Sq. (In.) B ((n.} C (in.) g & E Size 2 23A 4 E Medium Bronze Anodize 4 8~ 1~ 3/,x 25 2 x 4: 4 4 6 J Dark Bronze Painted 5 10~ 2~ 1 x 36 2 x 4: 5 3 4 U Black Painted 6 13 2'/, 1 x 36 2 x 4 v Gray Painted 6~ 13 2~ 1 x 36 2 x 4 W White Painted X None (Natural Aluminum) 1 Other colors available. Consult facton/. Accessories A ~" Tapped hub' B ~" Tapped hub' e Grounding lug (Max. wire #8 AWG) H Additional handhole and cover --I 2" below pole top- 90° from handhole 1 Location is 3' above has·-90° from handhole. Four Bolt Ancl Machining for Rectangular Arms --~'~ ~/-- B (add as suffix] Designation Letter &Number Quantity Lureark &Location' M3 3 900 M4 4 @ 90° E 1 Arm mounting holes located 45° from base holes. ~o~c