Loading...
Duke Freeport- LR160513May 13, 2016 Duke Realty South/West Region 14241 North Dallas Parkway, Suite 1000 ATTN:Mr. Sean Jeanes, P.E. LEED AP Tohatsu Location: Permits: Dallas, TX 75254 19:6710-A NEC Bethel Road and Freeport Parkway Coppell, TX RE: ECS Job # 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP LETTER OF TRANSMITTAL Texas Registered Engineering Firm # F-8461 CC:Duke Realty - Todd Henry Duke Realty - Glen Stevenson Pacheco Koch Consulting Engineers - Clayton J. Strolle, LEED AP City of Coppell - Matt Mabry Weir Bros., Inc. - Mike Weir ENCL: We are enclosing: Materials Engineering Division Reports For your use As requested X X X Field Report # 40 05/11/2016 Utility BF, Footing Timothy TarbuttonMark R. Zortman, P.E. Principal Engineer Project ManagerMAY 13 2016 1000.1 This report (and any included attachments) shall not be reproduced, except in full, without the prior written approval of ECS. ECS Texas, LLP 19:6710-A 40 Tohatsu Wednesday 05/11/2016 Project No. Report No. Day & DateProject 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] FIELD REPORT 3.50 The undersigned arrived on site, as requested, to observe: 1. The placement and compaction of soils for Sanitary Sewer Line SS-1B backfill. Utilizing the nuclear test method to check the compaction of soils; test results indicated that the compacted material, at the areas and elevations tested, met or exceeded the project requirements of 95% of the maximum dry density as obtained in our laboratory using the ASTM D 698-12 Method A Standard. Locations and elevations of all tests are based on stakeout provided by others. We cannot be responsible for structures located off of the observed engineered pad, misaligned utilities or stakeout errors causing uncontrolled fill to be placed in structural areas. 2. The bearing capacity of soil of Footings B-2. Utilizing a Dynamic Cone Penetrometer (ASTM STP-399) to check the bearing capacity of soil at the aforementioned locations, test results indicated that soils, at the areas and elevations tested, should be capable of supporting a foundation designed for a net allowable bearing capacity 3000 psf. Footing B-2 was excavated on 5/10/16. DCP testing was done 5/11/16 but concrete was not placed. Retesting will be required. 88°/ Sunny 55.00 2.00 0.50 0.00 01:00P 03:00P Utility BF, Footing Location Contractor On-Site Time Lab Time Client Coppell, TX Arrival Departure Summary of Services Performed (field test data, locations, elevations & depths are estimates) & Individuals Contacted. Duke Realty - Sean Jeanes, P.E. LEED AP Duke Realty - Sean Jeanes, P.E. LEED AP Trip Charges* Remarks Chargeable Items Weather Mileage* 1.00Travel Time* Total Time of Re Obs.Time * Travel time and mileage will be billed in accordance with the contract. Tolls/Parking* Milton E. Perez, — Field TechnicianBy 1705 1080396 Report of Spread Footing - Foundation Observations Project: Location: Contractor: Project No. Day/Date: LocationFooting Number Size (W x H x L) Design Actual Footing Bottom Elevation Depth of Undercut (in) Description of Steel Placed Description of Subgrade Material # of Blows / increment Design Bearing Pressure Design Required Blow Counts Tohatsu 6710-A NEC Bethel Road and Freeport Parkway Coppell - Dallas County - TX - 75019- Duke Realty 05/11/16 7' x 2'6" x 7'B2 7' x 2'6" x 7'97.5 2.5 .1 8 #5 CLAYEY Sand 5 8.0 3000 ECS Texas, LLP By:Milton E. Perez WO:61928 ECS TEXAS, LLP Test Method ASTM Nuclear Project No: Contractor: Project Name:Date: Client: Page 1 Technician: Nuclear Gauge No. Make Model Ser. No. Density Std Moisture Std 6710-A Tohatsu 05/11/16 Duke Realty Duke Realty Milton E. Perez 66373 Troxler 3430 3430 2023 644 Field Compaction Summary, ASTM Nuclear Description Proctor Method Uncorrected Max. Density Uncorrected Opt. MCSample No. D4S-5 Clayey SAND, Light Brown ASTM D 698-12 Method A Standard 116.70 11.40 Test Data Test No. Test Mode Station / Location Probe Depth (in.) Lift / Elev Corrected Maximum Dry Density (pcf) Corrected Optimum Moisture Content (%) % Oversize Wet Density (pcf) Dry Density (pcf) Moisture Content (%) Percent Comp. (%)CommentsP / F Sample No. 1 DT 6 Sanitary Sewer, SS-1B, STA 1+50 SG-3'6 " 0.00 116.70 11.40 131.0 111.3 17.6 95.4 PD4S-5 2 DT 6 Sanitary Sewer, SS-1B, STA 1+50 SG-3'0.00 116.70 11.40 131.4 111.1 18.2 95.2 PD4S-5 3 DT 6 Sanitary Sewer, SS-1B, STA 1+50 SG-2'6 " 0.00 116.70 11.40 130.6 111.1 17.5 95.2 PD4S-5 4 DT 6 Sanitary Sewer, SS-1B, STA 1+50 SG-2'0.00 116.70 11.40 130.9 111.0 18.0 95.1 PD4S-5 5 DT 6 Sanitary Sewer, SS-1B, STA 1+50 SG-1'6 " 0.00 116.70 11.40 134.0 114.0 17.6 97.7 PD4S-5 6 DT 6 Sanitary Sewer, SS-1B, STA 1+50 SG-1'0.00 116.70 11.40 129.3 111.3 16.1 95.4 PD4S-5 7 DT 6 Sanitary Sewer, SS-1B, STA 1+50 SG-6"0.00 116.70 11.40 134.2 115.8 15.9 99.2 PD4S-5 8 DT 6 Sanitary Sewer, SS-1B, STA 1+50 SG 0.00 116.70 11.40 132.5 113.4 16.9 97.2 PD4S-5 9 DT 6 Sanitary Sewer, SS-1B, STA 2+50 SG-3'6 " 0.00 116.70 11.40 131.4 111.0 18.3 95.1 PD4S-5 10 DT 6 Sanitary Sewer, SS-1B, STA 2+50 SG-3'0.00 116.70 11.40 131.5 111.2 18.2 95.3 PD4S-5 11 DT 6 Sanitary Sewer, SS-1B, STA 2+50 SG-2'6 " 0.00 116.70 11.40 130.6 111.9 16.7 95.9 PD4S-5 12 DT 6 Sanitary Sewer, SS-1B, STA 2+50 SG-2'0.00 116.70 11.40 130.4 111.2 17.2 95.3 PD4S-5 Test Mode: DT = Direct Transmission BS = Back Scatter WO:61928 ECS TEXAS, LLP Test Method ASTM Nuclear Project No: Contractor: Project Name:Date: Client: Page 2 Technician: Nuclear Gauge No. Make Model Ser. No. Density Std Moisture Std 6710-A Tohatsu 05/11/16 Duke Realty Duke Realty Milton E. Perez 66373 Troxler 3430 3430 2023 644 Field Compaction Summary, ASTM Nuclear Test Data Test No. Test Mode Station / Location Probe Depth (in.) Lift / Elev Corrected Maximum Dry Density (pcf) Corrected Optimum Moisture Content (%) % Oversize Wet Density (pcf) Dry Density (pcf) Moisture Content (%) Percent Comp. (%) P / F Sample No. Comments 13 DT 6 Sanitary Sewer, SS-1B, STA 2+50 SG-1'6 " 0.00 116.70 11.40 133.7 114.5 16.7 98.1 PD4S-5 14 DT 6 Sanitary Sewer, SS-1B, STA 2+50 SG-1'0.00 116.70 11.40 130.9 112.5 16.3 96.4 PD4S-5 15 DT 6 Sanitary Sewer, SS-1B, STA 2+50 SG-6"0.00 116.70 11.40 134.0 114.6 16.9 98.2 PD4S-5 16 DT 6 Sanitary Sewer, SS-1B, STA 2+50 SG 0.00 116.70 11.40 131.7 112.7 16.8 96.6 PD4S-5 Test Mode: DT = Direct Transmission BS = Back Scatter WO:61928