ST0301C- LR160419 (2)GEOTECHNICAL ENGINEERING
i ENVIRONMENTAL CONSULTING GEE Consultants, Inc.
E CONSTRUCTION MATERIALS TESTING
10046 Monroe Drive Dallas, Texas 75229 • (214) 352-5433 0 Fax (214) 352-6972
Report Date: April 19 2016 Date Concrete Placed, March 17, 2016 Standard 6"x12" Cylinders
Client: City of Coppell Cylinder Cross-sectional Area: 28.27 Square Inches
Project: Bethel & Coppell Road Concrete Report No.: 76
Contractor: Iron Concrete Constructions Project No.: 215-140
Concrete Supplier and Plant: ARGOS/ 111
Location of Placement: Inlet at Bethel Road
MATERIALS Source / SSD Batch Wts. OBSERVATION DATA
Description (Lbs/CaYd)
Mix Number: 10000001083 Time Sample Batched:
Cement: Time Sampled: 1:27 PM
Fly Ash:
Coarse Aggregate:
Intermediate Aggregate:
Fine Aggregate:
Admixtures:
L
Added Water: O''Gal
Sample Location:
Truck / Ticket No:
Temperature:
Ambient Range:
Concrete Range:
Slump Range (inches):
Weather Conditions:
Time Started:
Time Completed:
Sample Air Content (%):
Total Cubic Yards Placed:
Required Strength (Lbs,/sq.in.):
75 W. from Cross Section of
Bethel Rd. and Hearthstone Ln.,
30' S. from Building 301
0/01797941
66 OF
72 OF
4.25
Cloudy
12:00 PM
3:00 PM
3.0
9.0
4,000
Specimen
Number
"-�-
Measured
Slump (in.)
Age
(Days)
Date
Tested
Total Load
(Lbs.)
Compressive Strength
(Lbs./Sq.1n.)
Remarks
BCR 328
7
3/24/16
134,860
4,770
BCR 329
28
4/14/16
159,960
5,660
BCR 330
4.25
28
4/14/16
163,160+
5,770+
BCR 331
H
H
Test Methods Utilized
Fracture Regular
Cylinders Made By: YS
ASTM C-31, C-39, C-143
(Unless Noted Otherwise)
Remarks and/or Distribution:
cc: Mr, Rick Odell - City of Coppell via E-mail: Rodel]Li�coppelltx.gov
Mr. Michelle Matunas - City of Coppell via Email: mmatunasoa coppelltx.gov
Mr. George Marshall - City of Coppell via Email: gmarshall(a,coppelltx.gov
Mr. Robert Caudill - Tiseo Paving via Email: rcaudill cr,tiseopaving.com
GEE Consultants, Inc.
All letters and reports are for the exclusive use
our prior written approval. Our letters and
Firm: F-3212
the client to whom they are addressed and shall not be reproduced without the full approval of GEE Consultants, Inc. The use of our name must receive
ports apply only to the sample tested and/or observed and are not necessarily indicative of the quantities of apparently identical or similar products,