Loading...
Duke Freeport- LR160616LETTER OF TRANSMITTAL TO: ATTN: JOB NO.: DATE: RE: PERMIT #: LOCATION: We are enclosing: Attached Materials Engineering Division Concrete Reports:As Requested CC: By: For Your Use 06/16/2016 Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 006710A Mr. Sean Jeanes, P.E. LEED AP Duke Realty South/W est Region 14241 North Dallas Parkway, Suite 1000 Dallas, TX 75254 Duke Realty - Todd Henry Duke Realty - Glen Stevenson Mark R. Zortman, P.E. Principal Engineer Pacheco Koch Consulting Engineers - Clayton J. Strolle, City of Coppell - Matt Mabry Weir Bros., Inc. - Mike W eir Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Timothy Tarbutton Project Manager 15, 16, 17, 18, 19, 20, 28 CONCRETE, GROUT, AND MORTAR TESTS3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] X X X X Dallas County JUN 16 2016 ECS Texas, LLP Texas Registered Engineering Firm # F-8461 This report (and any included attachments) shall not be reproduced, except in full, without the prior written approval of ECS. 3500 psi Project: Location: Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway,15 05/18/2016 6710-AProject : 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] Concrete Cylinders Strength Report Set Designation:A ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Slab on Grade Pour 3 LMC 5030 63101829 1418 3500 psi 09:47AM 0Added W ater: 60º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Typ Review by FIELD TEST DATA:Milton E. Perez 10:16AM 5.50 in. 1.70 % (P) Tested by: 71º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq 47305974413442205/25/2016 7 Lab 4.01 12.62 2 TT02 52306606413442306/15/2016 28 Lab 4.01 12.62 3 TT02 52406624013442406/15/2016 28 Lab 4.01 12.62 3 TT02 51606489013442506/15/2016 28 Lab 4.00 12.56 3 TT02 16202048013442605/19/2016 1 Lab 4.01 12.62 3 TT02 FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or bonded caps iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing Box Ice Other Print Date:06/16/2016 TT02 BR01 3500 psi Project: Location: Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway,16 05/18/2016 6710-AProject : 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] Concrete Cylinders Strength Report Set Designation:B ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Slab on Grade Pour 3 LMC 3021 64407028 1418 3500 psi 10:54AM 5 Gals.Added W ater:Time Added:11:26AM 60º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Typ Review by FIELD TEST DATA:Milton E. Perez 11:27AM 5.25 in. 1.30 % (P) Tested by: 71º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq 46805916813442705/25/2016 7 Lab 4.01 12.62 2 TT02 50806480013442806/15/2016 28 Lab 4.03 12.75 3 TT02 49906307213442906/15/2016 28 Lab 4.01 12.62 3 TT02 51606521213443006/15/2016 28 Lab 4.01 12.62 3 TT02 134431 07/13/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or bonded caps iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing Box Ice Other Print Date:06/16/2016 TT02 BR01 3500 psi Project: Location: Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway,17 05/18/2016 6710-AProject : 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] Concrete Cylinders Strength Report Set Designation:C ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Slab on Grade Pour 3 LMC 1420 62996955 1418 3500 psi 12:28PM 0Added W ater: 60º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Typ Review by FIELD TEST DATA:Milton E. Perez 12:59PM 5.00 in. 1.10 % (P) Tested by: 68º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq 48406109213443205/25/2016 7 Lab 4.01 12.62 3 TT02 51706525613443306/15/2016 28 Lab 4.01 12.62 3 TT02 53006691213443406/15/2016 28 Lab 4.01 12.62 3 TT02 51406488013443506/15/2016 28 Lab 4.01 12.62 3 TT02 134436 07/13/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or bonded caps iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing Box Ice Other Print Date:06/16/2016 TT02 BR01 3500 psi Project: Location: Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway,18 05/18/2016 6710-AProject : 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] Concrete Cylinders Strength Report Set Designation:D ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Slab on Grade Pour 3 LMC 6037 63101866 1418 3500 psi 01:44PM 0Added W ater: 60º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Typ Review by FIELD TEST DATA:Milton E. Perez 02:30PM 5.50 in. 1.60 % (P) Tested by: 76º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq 48806160013443705/25/2016 7 Lab 4.01 12.62 3 TT02 53106672013443806/15/2016 28 Lab 4.00 12.56 3 TT02 51806547213443906/15/2016 28 Lab 4.01 12.62 3 TT02 51706494013444006/15/2016 28 Lab 4.00 12.56 3 TT02 134441 07/13/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or bonded caps iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing Box Ice Other Print Date:06/16/2016 TT02 BR01 3500 psi Project: Location: Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway,19 05/18/2016 6710-AProject : 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] Concrete Cylinders Strength Report Set Designation:E ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Slab on Grade Pour 3 LMC 0000 00000000 1418 3500 psi 02:50PM 0Added W ater: 60º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Typ Review by FIELD TEST DATA:Milton E. Perez 03:40PM 5.50 in. 1.80 % (P) Tested by: 75º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq 49206188813444205/25/2016 7 Lab 4.00 12.56 2 TT02 53306731213444306/15/2016 28 Lab 4.01 12.62 3 TT02 51806540813444406/15/2016 28 Lab 4.01 12.62 3 TT02 52106580413444506/15/2016 28 Lab 4.01 12.62 3 TT02 134446 07/13/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or bonded caps iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing Box Ice Other Print Date:06/16/2016 TT02 BR01 3500 psi Project: Location: Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway,20 05/18/2016 6710-AProject : 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] Concrete Cylinders Strength Report Set Designation:F ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Slab on Grade Pour 3 LMC 9150 64407100 1418 3500 psi 04:09PM 0Added W ater: 66º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Typ Review by FIELD TEST DATA:Milton E. Perez 04:48PM 5.75 in.Tested by: 74º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq 48106074013444705/25/2016 7 Lab 4.01 12.62 2 TT02 52906680813444806/15/2016 28 Lab 4.01 12.62 3 TT02 51406489613444906/15/2016 28 Lab 4.01 12.62 3 TT02 51806515213445006/15/2016 28 Lab 4.00 12.56 3 TT02 134451 07/13/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or bonded caps iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing Box Ice Other Print Date:06/16/2016 TT02 BR01 3000 psi Project: Location: Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway,28 06/08/2016 6710-AProject : 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] Concrete Cylinders Strength Report Set Designation:A ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Continuous Footings at Grind lines E-G.5/1 LMC 5007 64408260 5150 3000 psi 03:27PM 0Added W ater: 91º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Typ Review by FIELD TEST DATA:Milton E. Perez 04:09PM 4.00 in. 2.10 % (P) Tested by: 90º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq 25003158413546306/15/2016 7 Lab 4.01 12.62 3 TT02 135464 07/06/2016 28 Lab 135465 07/06/2016 28 Lab 135466 07/06/2016 28 Lab 135467 08/03/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or bonded caps iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing Box IceX Other Print Date:06/16/2016 TT02 BR01