Fountain Park 1-CS 930609 (2)The City With A Be '
June 9, 1993
Mr. Lynn Kadleck
Kadleck & Associates
5336 Alpha Road, Sui
Dallas, TX 75240
te5
Fountain Park Addition
Construction Plans
Dear Mr. Kadleck: I
The City of Coppell has
comments to offer:
P.O. Box 478
Coppell, Texas 75019
214-462-0022
received and reviewed the referenced plans and has the following
1) The open ~pace area shown on the final plat sheet should be labeled as a common
area and there should be a note stating that it will be maintained by the Homeowners
Association.
2) On the drz4nage area map and detail sheet, make the correction to the drainage area
number. 1
3) Provide b~ck pavers for the street return on Fountain View Place as called for in the
City of Cqppell Streetscape Plan. Also, provide brick pavers for the wheelchair
ramps.
4) Referring
within the
line be con
the 24" cle
5) On the gr
following:
6) In the ero~
around the
Sheet 5, the proposed 8" sanitary sewer agq:w, ars to cross the storm inlet
ninimum 24" clearance. Therefore, it is necessary that the sanitary sewer
xete encased. Check all other areas where two utilities may cross within
Lrance and concrete encase as required.
~ding plan and note sheet (Sheet //7), add a general note stating the
"Shall submit a traffic control plan consistent with the T.M.U.T.C.D".
ion and sedimentation control plan sheet (sheet//8), provide a silt fence
edge of the entire project. Also, show all the street names.
10) Provide the p
attached shee!
7) Make the chmages to the general notes and layout on the water and sanitary sewer
plans as indic4ted on the plans.
8) Construction 41ans need to be signed and sealed by a registered professional engineer.
9) The City wou~d prefer to have a storm sewer system on Fountain Drive instead of
the no crown section to convey storm water runoff.
tan approval paragraph for the City of Coppell on the title sheet (see
I.
There are various other
been addressed, the revi
should have any questio~
convenience.
Sincerely,
ninor comments throughout these plans. Once these comments have
ed set of plans should be resubmitted to the City for review. If you
ts concerning these comments, please feel free to contact me at your
Michael A. Martin, E.I.T.
file/mmartin/review.ltr
RE:
RE:
Plane Prel>=l
Sheet
Specification;
Sheet
Construction
EJ~piration dc
PLAN APPROVAL PARAGRAPH
For City Engineer
'ed by
of Last Revsion date
Prepared by
of Last Revision date
Plans and Specifications Effective date
The above identified plane and specifications have been reviewed and found
to be in compllanc~with the applicable Engineering provisions of the Municipal
Code of the City cfr C~oppell, Texas. Issuance of this approval shall not be
oonatrucd as approval of the concept for the consteuction details of the proposed
improvements and alkali not in any way release the Owner/Developer and the
Design Engineer fro~ liability for the adequacy of the design nor from liability
/
caused by or eeeultir~g from the construction of improvements ~oae provided for
in the above eplcified documents.
The ieeuance of thie approval doee not authorize construction, which construction
shall not proceed un[il the owner has effected compliance with all other applicable
provieione of the Mu~icil~t Code of the City of Coppell, Texas and compliance
of oil other ~tete st,~tutee, and regulcrtory requirements applicable to the
improvements epeciflKI in the identified documents, including completion of
any and all requirerr.ents of ~U~ City of Coppell. Texas requiring any approval
of the Planning and Zoning Commission and City Council payment of alt fees,
posting of all bonds and then securing on 'Approval to Proceecf' from the City
Engineer.'
Any changes must be approved by the appropriate regulatory agencies as well
as the City Engineer. After the Developer's Design Engineer approves the
change, the ~City's allsigned Engineering Inspector shall be constulted who
will 'eRher approve qnd/or secure approval from the City Engineer. at which
time a supplemental plan approved will be affixed to the approved ptons, and
/
referenced in a supplemental oppravol letter by the City Engineer. Alt revisions
wilt be included in ihs 'As-Built' plans to be submit~red 50 days after substantial
comple~ion~10f all p~blic improvements.
/
CITY ENGINEER DATE