Loading...
Duke Freeport-LR160726August 1, 2016 Duke Realty South/West Region 14241 North Dallas Parkway, Suite 1000 ATTN:Mr. Sean Jeanes, P.E. LEED AP Tohatsu Location: Permits: Dallas, TX 75254 19:6710-A NEC Bethel Road and Freeport Parkway Coppell, TX RE: ECS Job # 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP LETTER OF TRANSMITTAL Texas Registered Engineering Firm # F-8461 CC:Duke Realty - Todd Henry Duke Realty - Glen Stevenson Pacheco Koch Consulting Engineers - Clayton J. Strolle, LEED AP City of Coppell - Matt Mabry Weir Bros., Inc. - Mike Weir Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz ENCL: We are enclosing: Materials Engineering Division Reports For your use As requested X X X Field Report # 86A 07/26/2016 Structural Steel Non Compliance Noted Timothy TarbuttonMark R. Zortman, P.E. Principal Engineer Project ManagerAUG 1 2016 1000.1 This report (and any included attachments) shall not be reproduced, except in full, without the prior written approval of ECS. ECS Texas, LLP 19:6710-A 86A Tohatsu Tuesday 07/26/2016 Project No. Report No. Day & DateProject 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] FIELD REPORT 4.50 Visual Structural Steel Observation: On this date, a representative of ECS, arrived on site as requested to perform a visual observation of the structural steel installation. An Observation Report is attached. The remarks and/or discrepancies are noted on the report. 55.00 4.50 0.00 0.00 *** Non Compliance Noted *** 12:00P 04:30P Structural Steel Location Contractor On-Site Time Lab Time Client Coppell, TX Arrival Departure Summary of Services Performed (field test data, locations, elevations & depths are estimates) & Individuals Contacted. Duke Realty - Sean Jeanes, P.E. LEED AP Duke Realty - Sean Jeanes, P.E. LEED AP Trip Charges* Remarks Chargeable Items Weather Mileage* 0.00Travel Time* Total Time of Re Obs.Time * Travel time and mileage will be billed in accordance with the contract. Tolls/Parking* SUBCONTRACTORBy 7100 1089341 REPORT OF STRUCTURAL STEEL INSPECTION Project:Tohatsu Report No:52390-6 670 Freeport Pkwy, Coppell, TX Attention: Client:ECS - Texas, LLP Date of Service:7/26/2016 4950 Keller Springs Road #480 Addison, TX 75001 Page 1 of 1 REPORT OF INSPECTION Drawings utilized:Structural Locations/item inspected:As Noted Below Discrepancies/comments: A visual inspection was performed and the results are as follows: I.) Joist Seats Line 1/F-L Except Panel W13 * A.) 7 Joist Seats (Painted) - Non-Compliant, not full 3" seat. II.) Girder Seats Line 1 * A.) 3 Girder Seats (Painted) - Non-Compliant, not full 4" seat. * - Open Items Lindon Carr, CWI #15061011 Technician Steel Inspectors of Texas, Inc. This report is for the exclusive use of our client and shall not be modified or reproduced without written approval from said client